WIKA operating instructions air2guide model A2G-70
40202801.03 08/2012 GB/D/F/E/I
Contents
Contents
1.General information4
2.Safety5
3.Specications6
Design and function
4.
5.Transport, packaging and storage9
6.Commissioning, operation9
7.Maintenance and cleaning12
8.Disposal12
8
GB
40202801.03 08/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-70
3
1. General information
1. General information
■
The duct sensor for relative humidity and temperature described in
the operating instructions has been manufactured using state-of-theart technology. All components are subject to stringent quality and
GB
environmental criteria during production. Our management systems
are certied to ISO 9001 and ISO 14001.
■
These operating instructions contain important information on
handling the instrument. Working safely requires that all safety
instructions and work instructions are observed.
■
Observe the relevant local accident prevention regulations and
general safety regulations for the instrument's range of use.
■
The operating instructions are part of the product and must be kept
in the immediate vicinity of the instrument and readily accessible to
skilled personnel at any time.
■
Skilled personnel must have carefully read and understood the
operating instructions prior to beginning any work.
■
The manufacturer's liability is void in the case of any damage caused
by using the product contrary to its intended use, non-compliance
with these operating instructions, assignment of insuciently qualied skilled personnel or unauthorised modications to the instru-
ment.
■
The general terms and conditions contained in the sales documentation shall apply.
■
Subject to technical modications.
■
Further information:
- Internet address:www.wika.de / www.wika.com
www.air2guide.com
- Relevant data sheet:TE 62.91
4
WIKA operating instructions air2guide model A2G-70
40202801.03 08/2012 GB/D/F/E/I
1. General information / 2. Safety
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result
in serious injury or death, if not avoided.
Information
... points out useful tips, recommendations and information
for ecient and trouble-free operation.
2. Safety
WARNING!
Before installation, commissioning and operation, ensure
that the appropriate duct sensor for relative humidity and
temperature has been selected in terms of measuring
range, design and specic measuring conditions.
Non-observance can result in serious injury and/or damage
to the equipment.
Further important safety instructions can be found in the
individual chapters of these operating instructions.
2.1 Intended use
■
For measuring the relative humidity and temperature of gaseous
media in heating, ventilation and air-conditioning systems (e. g. in
fresh-air and exhaust-air ducts)
■
Designed for connection to control and display systems
The instrument has been designed and built solely for the intended use
described here, and may only be used accordingly.
The manufacturer shall not be liable for claims of any type based on
operation contrary to the intended use.
GB
40202801.03 08/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-70
5
2. Safety / 3. Specications
2.2 Personnel qualication
WARNING!
Risk of injury should qualication be insucient!
GB
Skilled personnel
Skilled personnel are understood to be personnel who, based on their
technical training, knowledge of measurement and control technology
and on their experience and knowledge of country-specic regulations,
current standards and directives, are capable of carrying out the work
described and independently recognising potential hazards.
Explanation of symbols
3. Specications
Improper handling can result in considerable injury and
damage to equipment.
■
The activities described in these operating instructions
may only be carried out by skilled personnel who have
the qualications described below.
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant
European directives.
Electrical connection
Screw terminal max. 1.5 mm
2
Cable gland M16 x 1.5 for conductors with D = 8 mm max.
Power supply
DC 15 ... 24 V / AC 24 V ±10 %
Power consumption
Typically 0.5 W / 1.7 VA
6
WIKA operating instructions air2guide model A2G-70
40202801.03 08/2012 GB/D/F/E/I
3. Specications
Transmitter output
Humidity: DC 0 ... 10 V, load: min. 5 kΩ
Temperature: DC 0 ... 10 V, load: min. 5 kΩ
Transmitter output 4 ... 20 mA (option)
Humidity: 4 ... 20 mA, load < 500 Ω for DC 24 V
Temperature: 4 ... 20 mA, load < 500 Ω for DC 24 V
Dimensions in mm
Insertion length L
Standard 140 mm
Mounting ange MF19-PA
GB
40202801.03 08/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-70
7
3. Specications / 4. Design and function
Ingress protection
IP 65 per EN 60529 / lEC 529 (connection head)
For further specications see WIKA data sheet TE 62.91 and the order
documentation.
GB
4. Design and function
4.1 Description
Design
CE conformity: 2004/108/EC electromagnetic compatibility
Product safety: 2001/95/EC product safety
EMC: EN 607301: 2002
Product safety: EN 607301: 2002
Accuracy
Humidity: ±3 % between 20 … 80 % rH
Temperature: ±1 % between 5 … 45 °C
Scale range / measuring range
Humidity: 0 … 100 % rH
Temperature: -20 … +80 °C
Permissible temperature
Ambient: -20 … +70 °C
Sensor tip: max. 60 °C
4.2 Scope of delivery
Cross-check scope of delivery with delivery note.
8
WIKA operating instructions air2guide model A2G-70
Duct sensor for relative humidity and temperature for any damage that
may have been caused by transport.Obvious damage must be reported
immediately.
5.2 Packaging
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during transport (e.g. change in installation site, sending for repair).
5.3 Storage
Permissible conditions at the place of storage
Storage temperature: -20 ... +70 °C
Protect the instruments from moisture and dust.
6. Commissioning, operation
Installation and mechanical connection
■
Protect measuring instruments from contamination, high temperature
changes and vibrations
■
In order to avoid any additional heating, the instruments must not
be exposed to direct solar irradiation while in operation.
GB
■
The duct humidity sensor for relative humidity and temperature
can be fastened directly to the ventilation duct using either a
mounting ange or screws.
40202801.03 08/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-70
9
6. Commissioning, operation
GB
Electrical connection
Connection diagram
The instruments are designed to operate with safety extra-low voltage
(SELV). The transmitters must be operated at a constant operating
voltage (±0.2 V). Current/voltage spikes from switching the power
supply on or o must be prevented by the customer.
Connection diagram for output 4 ... 20 mA (standard)
Out Temp 0-10V
Out RH 0-10V
UB 15-24V=/ 24V~
Gnd
Temp. sensor
Load
10
Load
WIKA operating instructions air2guide model A2G-70
(option)
DRW_TH0.04a
40202801.03 08/2012 GB/D/F/E/I
6. Commissioning, operation
Connection diagram for output 4 ... 20 mA (option)
UB 15-24 V=
GND / Temp Out 4-20 mA
UB 15-24 V=
GND / rF/rH Out 4-20 mA
Temp.
Oset
rF / rH
Oset
Note
If only the humidity output is used, U
15 ... 24 V= (rF/rH) and the temperature output "GND / Temp Out 4 ... 20 mA"
U
B
must be bridged to GND of the voltage supply.
15 ... 24 V= (temp.) must be bridged to
B
Mounting instructions
Max. air velocity 10 m/s
Notes for users
Due to air circulation, dirt and dust particles might occur on the sintered
lter that protects the sensors; these particles might impair the sensor
function. After dismounting the lter, it may be cleaned by blowing it out
using oil-free and ltered compressed air, ultrapure air or nitrogen or
washing it using distilled water. Filters that are too heavily soiled should
be replaced.
Do not touch the delicate humidity sensors as this voids warranty.
If used in aggressive gas atmospheres, an early recalibration or replacement of the humidity sensors might be required. Such a recalibration or
possible sensor replacement is not covered by warranty.
GB
DRW_TH0.05
40202801.03 08/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-70
11
7. Maintenance and cleaning / 8. Disposal
7. Maintenance and cleaning
The duct sensor for relative humidity and temperature is maintenance-
free and oers long service life provided it is handled and operated
properly.
GB
Clean the instruments with a moist cloth (soap water).
Repairs must only be carried out by the manufacturer or appropriately
qualied skilled personnel.
8. Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an
environmentally compatible way and in accordance with the country-
specic waste disposal regulations.
12
WIKA operating instructions air2guide model A2G-70
40202801.03 08/2012 GB/D/F/E/I
Inhalt
Inhalt
1.Allgemeines14
2.Sicherheit15
3.Technische Daten16
Aufbau und Funktion
4.
5.Transport, Verpackung und Lagerung19
6.Inbetriebnahme, Betrieb19
7.Wartung und Reinigung22
8.Entsorgung22
18
D
40202801.03 08/2012 GB/D/F/E/I
WIKA Betriebsanleitung air2guide Typ A2G-70
13
1. Allgemeines
1. Allgemeines
■
Der in der Betriebsanleitung beschriebene Kanalfühler für relative
Feuchte und Temperatur wird nach dem aktuellen Stand der Technik
konstruiert und gefertigt. Alle Komponenten unterliegen während der
Fertigung strengen Qualitäts- und Umweltkriterien. Unsere Manage-
mentsysteme sind nach ISO 9001 und ISO 14001 zertiziert.
D
■
Diese Betriebsanleitung gibt wichtige Hinweise zum Umgang mit
dem Gerät. Voraussetzung für sicheres Arbeiten ist die Einhaltung
aller angegebenen Sicherheitshinweise und Handlungsanweisungen.
■
Die für den Einsatzbereich des Gerätes geltenden örtlichen Unfallverhütungsvorschriften und allgemeinen Sicherheitsbestimmungen
einhalten.
■
Die Betriebsanleitung ist Produktbestandteil und muss in unmittelbarer Nähe des Gerätes für das Fachpersonal jederzeit zugänglich
aufbewahrt werden.
■
Das Fachpersonal muss die Betriebsanleitung vor Beginn aller
Arbeiten sorgfältig durchgelesen und verstanden haben.
■
Die Haftung des Herstellers erlischt bei Schäden durch bestimmungswidrige Verwendung, Nichtbeachten dieser Betriebsanleitung,
Einsatz ungenügend qualizierten Fachpersonals sowie eigenmächtiger Veränderung am Gerät.
■
Es gelten die allgemeinen Geschäftsbedingungen in den Verkaufsunterlagen.
… weist auf eine möglicherweise gefährliche Situation hin,
die zum Tod oder zu schweren Verletzungen führen kann,
wenn sie nicht gemieden wird.
Information
… hebt nützliche Tipps und Empfehlungen sowie Infor-
mationen für einen ezienten und störungsfreien Betrieb
hervor.
2. Sicherheit
WARNUNG!
Vor Montage, Inbetriebnahme und Betrieb sicherstellen,
dass der richtige Kanalfühler für relative Feuchte und
Temperatur hinsichtlich Messbereich, Ausführung und
spezischen Messbedingungen ausgewählt wurde.
Bei Nichtbeachten können schwere Körperverletzungen
und/oder Sachschäden auftreten.
Weitere wichtige Sicherheitshinweise benden sich in den
einzelnen Kapiteln dieser Betriebsanleitung.
2.1 Bestimmungsgemäße Verwendung
■
Zur Messung der relativen Feuchte und Temperatur in gasförmigen Medien von Heizungs-, Lüftungs- und Klimaanlagen (z. B.
in Zuluft- und Abluftkanälen)
■
Ausgelegt zur Aufschaltung an Regler- und Anzeigesystemen
Das Gerät ist ausschließlich für den hier beschriebenen bestimmungsgemäßen Verwendungszweck konzipiert und konstruiert und darf nur
dementsprechend verwendet werden.
Ansprüche jeglicher Art aufgrund von nicht bestimmungsgemäßer
Verwendung sind ausgeschlossen.
40202801.03 08/2012 GB/D/F/E/I
WIKA Betriebsanleitung air2guide Typ A2G-70
D
15
2. Sicherheit / 3. Technische Daten
2.2 Personalqualikation
WARNUNG!
Verletzungsgefahr bei unzureichender Qualikation!
Unsachgemäßer Umgang kann zu erheblichen Personenund Sachschäden führen.
■
D
Fachpersonal
Das Fachpersonal ist aufgrund seiner fachlichen Ausbildung, seiner
Kenntnisse der Mess- und Regelungstechnik und seiner Erfahrungen
sowie Kenntnis der landesspezischen Vorschriften, geltenden Normen
und Richtlinien in der Lage, die beschriebenen Arbeiten auszuführen
und mögliche Gefahren selbstständig zu erkennen.
Explanation of symbols
3. Technische Daten
Die in dieser Betriebsanleitung beschriebenen
Tätigkeiten nur durch Fachpersonal nachfolgend
beschriebener Qualikation durchführen lassen.
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant
European directives.
Elektrischer Anschluss
Schraubklemme max. 1,5 mm
2
Kabelverschraubung M16 x 1,5 für Leiter mit max. D = 8 mm
Hilfsenergie
DC 15 ... 24 V / AC 24 V ±10 %
Leistungsaufnahme
Typ. 0,5 W / 1,7 VA
16
WIKA Betriebsanleitung air2guide Typ A2G-70
40202801.03 08/2012 GB/D/F/E/I
Loading...
+ 36 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.