WIKA A2G-65 User Manual [en, de, es, fr, it]

Operating instructions Betriebsanleitung Mode d'emploi Manual de instrucciones Manuale d'uso
Frost protection thermostat model A2G-65
Frostschutzthermostat Typ A2G-65
Termostato antihielo modelo A2G-65
Termostato antigelo modello A2G-65
Frost protection thermostat model A2G-65
GB
D
F
E
I
GB
Operating instructions model A2G-65 Page 3-11
D
Betriebsanleitung Typ A2G-65 Seite 13-21
F
Mode d'emploi type A2G-65 Page 23-31
E
Manual de instrucciones modelo A2G-65 Página 33-41
I
Manuale d'uso modello A2G-65 Pagina 43-51
© 2011 WIKA Alexander Wiegand SE & Co. KG All rights reserved. / Alle Rechte vorbehalten.
®
WIKA
is a registered trademark in various countries.
®
WIKA
ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions! Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen! Zum späteren Gebrauch aufbewahren!
Lire le mode d‘emploi avant de commencer toute opération ! A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo! ¡Guardar el manual para una eventual consulta!
Prima di iniziare ad utilizzare lo strumento, leggere il manuale d‘uso! Conservare per future consultazioni!
2
WIKA operating instructions air2guide model A2G-65
40338355.02 05/2012 GB/D/F/E/I
Contents
Contents
1. General information 4
2. Safety 5
3. Specications 6
Design and function
4.
5. Transport, packaging and storage 9
6. Commissioning, operation 9
7. Options and accessories 11
8. Maintenance and cleaning 11
9. Disposal 11
8
GB
40338355.02 05/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-65
3
1. General information
1. General information
The frost protection thermostat described in the operating instruc­tions has been designed and manufactured using state-of-the-art technology. All components are subject to stringent quality and
GB
environmental criteria during production. Our management systems
are certied to ISO 9001 and ISO 14001.
These operating instructions contain important information on handling the instrument. Working safely requires that all safety instructions and work instructions are observed.
Observe the relevant local accident prevention regulations and general safety regulations for the instrument’s range of use.
The operating instructions are part of the product and must be kept in the immediate vicinity of the instrument and readily accessible to skilled personnel at any time.
Skilled personnel must have carefully read and understood the operating instructions, prior to beginning any work.
The manufacturer’s liability is void in the case of any damage caused by using the product contrary to its intended use, non-compliance
with these operating instructions, assignment of insuciently qualied skilled personnel or unauthorised modications to the
instrument.
The general terms and conditions contained in the sales documentation shall apply.
Subject to technical modications.
Further information:
- Internet address: www.wika.de / www.wika.com www.air2guide.com
- Relevant data sheet: TE 62.92
4
WIKA operating instructions air2guide model A2G-65
40338355.02 05/2012 GB/D/F/E/I
1. General information / 2. Safety
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation which can result in serious injury or death if not avoided.
Information
… points out useful tips, recommendations and information
for ecient and trouble-free operation.
2. Safety
WARNING!
Before installation, commissioning and operation, ensure that the appropriate frost protection thermostat has been
selected in terms of measuring range, design and specic
measuring conditions.
Non-observance can result in serious injury and/or damage to the equipment.
Further important safety instructions can be found in the individual chapters of these operating instructions.
2.1 Intended use
This frost protection thermostat is used for air-side temperature control and prevention of frost damage to water heating coils in ventilation and air-conditioning systems
GB
The instrument has been designed and built solely for the intended use described here and may only be used accordingly.
The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use.
40338355.02 05/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-65
5
2. Safety / 3. Specications
2.2 Personnel qualication
WARNING!
Risk of injury if qualication is insucient!
GB
Improper handling can result in considerable injury and damage to equipment.
The activities described in these operating instructions may only be carried out by skilled personnel who have
the qualications described below.
Skilled personnel
Skilled personnel are understood to be personnel who, based on their technical training, knowledge of measurement and control technology
and on their experience and knowledge of country-specic regulations,
current standards and directives, are capable of carrying out the work described and independently recognising potential hazards.
Explanation of symbols
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant European directives.
3. Specications
Capillary tube
Copper alloy Length 3 m, optional 1.8 or 6 m
Capillary tube lling
R 507
Resetting
automatic, manual optional
6
WIKA operating instructions air2guide model A2G-65
40338355.02 05/2012 GB/D/F/E/I
3. Specications
Electrical connection
Screw terminal max. 2.5 mm
2
Cable gland M16 x 1.5
Permissible temperature
Ambient: -30 … +70 °C, max. 85 % rH, non-condensing Medium: w + minimum 2 K … 70 °C (w = selected set point)
Housing material
Lower body: PA GK30 Cover: ABS transparent
Dimensions in mm
GB
Ingress protection
IP 65 per EN 60529 / lEC 529
For further specications see WIKA data sheet TE 62.92 and the order
documentation.
40338355.02 05/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-65
7
4. Design and function
4. Design and function
Description
Design
CE conformity: 2004/108/EG Electromagnetic compatibility (EMC)
GB
Product safety: 2001/95/EC Product safety
EMC: EN 60730-1: 2002 Product safety: EN 60730-1: 2002
Adjustable range for set point
-10 … +15 °C (Factory setting: 5 °C)
Switching dierential
≤ 2 ±1 °C
Repeatability
±0.5 °C
Sensor active length
approx. 60 cm
Switching output
Changeover contact, max. AC 250 V, max. 10 A
Contact material: Ag / Ni (90 % / 10 %), gold-plated (3 µm)
Scope of delivery
Cross-check the scope of delivery with the delivery note.
8
WIKA operating instructions air2guide model A2G-65
40338355.02 05/2012 GB/D/F/E/I
5. Transport, packaging ... / 6. Commissioning, operation
5. Transport, packaging and storage
5.1 Transport
Check the frost protection thermostat for any damage that may have been caused during transportation. Obvious damage must be reported immediately.
5.2 Packaging
Do not remove packaging until just before mounting. Keep the packaging as it will provide optimum protection during trans­port (e.g. change in installation site, sending for repair).
5.3 Storage
Permissible conditions at the place of storage:
Storage temperature: -30 ... +70 °C Protect frost protection thermostat from moisture and dust.
6. Commissioning, operation
Installation and mechanical connection
The ambient temperature at the frost protection thermostat housing (with the test loop) must be at least 2 °C above the selected set point. If this cannot be guaranteed (e.g. outdoors or in exposed areas), the housing and test loop must be installed inside the air handling unit.
The capillary tube must be mounted on the downstream side of the heating coil (and on the upstream side in the case of cooling coils). It should be looped diagonally across the heat exchanger pipes at a distance of approx. 5 cm and should cover the entire area evenly. For test purposes, it is recommended to have a loop of approx. 60 cm directly beneath the housing outside the entry to the duct. To prevent damage to the capillary tube, a minimum bending radius of 20 mm must be ensured. Mounting can be made easier by using capillary tube clamps (optional accessories).
GB
40338355.02 05/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-65
9
6. Commissioning, operation
Connection diagram
GB
1 - 2 Normal operation 1 - 4 Risk of frost
The switch in the frost protection thermostat trips when the tempera­ture over a capillary length of at least 60 cm drops below the selected set point (contact 1-4 makes). Simultaneously, contact 1-2 breaks and can be used as a signal contact. An automatic reset (contact 1-2 makes) occurs when the temperature once again exceeds the selected set point. The air2guide AFT is “intrinsically safe”, i.e. in the event of any damage to the capillary tube diaphragm system, it automatically switches to the heating function. Contact 1-4 makes and can thus be used as an operating contact. The air temperature is measured over the full length of the sensor (capillary tube).
Commissioning
It is recommended to mount the frost protection thermostat on a special plate (slide-in module), directly downstream of the heating coil. The connecting cable must therefore be long enough to enable the plate to be inserted and removed smoothly. For heating coils with a very large
cross section, several frost protection thermostats can be tted and
connected in series. In such cases, the temperature set point is set individually for each frost protection thermostat.
10
WIKA operating instructions air2guide model A2G-65
40338355.02 05/2012 GB/D/F/E/I
7. Options and accessories ... 9. Disposal
7. Options and accessories
Standard accessories
Mounting clamps, 6 pieces for 6 m long capillary tube
2 x grommets DA 20/80/10
Options
Manual resetting
Capillary tube length 1.8 or 6 m
8. Maintenance and cleaning
The frost protection thermostat is maintenance-free and oers long
service life provided it is handled and operated properly.
Clean the instruments with a moist cloth (soap water).
Repairs must only be carried out by the manufacturer or appropriately
qualied skilled personnel.
9. Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an environmentally compatible way and in accordance with the country-
specic waste disposal regulations.
GB
40338355.02 05/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-65
11
GB
12
WIKA operating instructions air2guide model A2G-65
40338355.02 05/2012 GB/D/F/E/I
Inhalt
Inhalt
1. Allgemeines 14
2. Sicherheit 15
3. Technische Daten 16
Aufbau und Funktion
4.
5. Transport, Verpackung und Lagerung 19
6. Inbetriebnahme, Betrieb 19
7. Optionen und Zubehör 21
8. Wartung und Reinigung 21
9. Entsorgung 21
18
D
40338355.02 05/2012 GB/D/F/E/I
WIKA Betriebsanleitung air2guide Typ A2G-65
13
1. Allgemeines
1. Allgemeines
Der in der Betriebsanleitung beschriebene Frostschutzthermostat wird nach den neuesten Erkenntnissen konstruiert und gefertigt. Alle Komponenten unterliegen während der Fertigung strengen Qualitäts- und Umweltkriterien. Unsere Managementsysteme sind
nach ISO 9001 und ISO 14001 zertiziert.
D
Diese Betriebsanleitung gibt wichtige Hinweise zum Umgang mit dem Gerät. Voraussetzung für sicheres Arbeiten ist die Einhaltung aller angegebenen Sicherheitshinweise und Handlungsanwei­sungen.
Die für den Einsatzbereich des Gerätes geltenden örtlichen Unfall­verhütungsvorschriften und allgemeinen Sicherheitsbestimmungen einhalten.
Die Betriebsanleitung ist Produktbestandteil und muss in unmittel­barer Nähe des Gerätes für das Fachpersonal jederzeit zugänglich aufbewahrt werden.
Das Fachpersonal muss die Betriebsanleitung vor Beginn aller Arbeiten sorgfältig durchgelesen und verstanden haben.
Die Haftung des Herstellers erlischt bei Schäden durch bestim­mungswidrige Verwendung, Nichtbeachten dieser Betriebsanleitung, Einsatz ungenügend qualizierten Fachpersonals sowie eigenmäch­tiger Veränderung am Gerät.
Es gelten die allgemeinen Geschäftsbedingungen in den Verkaufs­unterlagen.
Technische Änderungen vorbehalten.
Weitere Informationen:
- Internet-Adresse: www.wika.de / www.wika.com www.air2guide.com
- zugehöriges Datenblatt: TE 62.92
14
WIKA Betriebsanleitung air2guide Typ A2G-65
40338355.02 05/2012 GB/D/F/E/I
1. Allgemeines / 2. Sicherheit
Symbolerklärung
WARNUNG!
… weist auf eine möglicherweise gefährliche Situation hin, die zum Tod oder zu schweren Verletzungen führen kann, wenn sie nicht gemieden wird.
Information
… hebt nützliche Tipps und Empfehlungen sowie Infor-
mationen für einen ezienten und störungsfreien Betrieb
hervor.
2. Sicherheit
WARNUNG!
Vor Montage, Inbetriebnahme und Betrieb sicherstellen, dass das richtige Frostschutzthermostat hinsichtlich Messbereich, Ausführung und spezischen Messbedin­gungen ausgewählt wurde. Bei Nichtbeachten können schwere Körperverletzungen und/oder Sachschäden auftreten.
Weitere wichtige Sicherheitshinweise benden sich in den
einzelnen Kapiteln dieser Betriebsanleitung.
2.1 Bestimmungsgemäße Verwendung
Dieser Frostschutzthermostat dient zur luftseitigen Temperaturüberwa­chung und Verhinderung von Frostschäden von Wasser-Lufterwärmern in Lüftungs- und Klimaanlagen
D
Das Gerät ist ausschließlich für den hier beschriebenen bestimmungs­gemäßen Verwendungszweck konzipiert und konstruiert und darf nur dementsprechend verwendet werden.
Ansprüche jeglicher Art aufgrund von nicht bestimmungsgemäßer Verwendung sind ausgeschlossen.
40338355.02 05/2012 GB/D/F/E/I
WIKA Betriebsanleitung air2guide Typ A2G-65
15
2. Sicherheit / 3. Technische Daten
2.2 Personalqualikation
WARNUNG!
Verletzungsgefahr bei unzureichender Qualikation!
Unsachgemäßer Umgang kann zu erheblichen Personen­und Sachschäden führen.
D
Die in dieser Betriebsanleitung beschriebenen Tätig­keiten nur durch Fachpersonal nachfolgend beschrie-
bener Qualikation durchführen lassen.
Fachpersonal
Das Fachpersonal ist aufgrund seiner fachlichen Ausbildung, seiner Kenntnisse der Mess- und Regelungstechnik und seiner Erfahrungen
sowie Kenntnis der landesspezischen Vorschriften, geltenden Normen
und Richtlinien in der Lage, die beschriebenen Arbeiten auszuführen und mögliche Gefahren selbstständig zu erkennen.
Symbolerklärung
CE, Communauté Européenne
Geräte mit dieser Kennzeichnung stimmen überein mit den
zutreenden europäischen Richtlinien.
3. Technische Daten
Kapillarrohr
Kupferlegierung Länge 3 m, optional 1,8 oder 6 m
Kapillarrohrfüllung
R 507
Rückstellung
automatisch, optional manuell
16
WIKA Betriebsanleitung air2guide Typ A2G-65
40338355.02 05/2012 GB/D/F/E/I