WIKA A2G-60 User Manual [en, de, es, fr, it]

Operating instructions Betriebsanleitung Mode d'emploi Manual de instrucciones Manuale d'uso
Duct/immersion temperature sensor model A2G-60
Kanal-/Tauchtemperaturfühler Typ A2G-60
Capteur de température de gaine/à plongeur type A2G-60
Sensor de temperatura de canal / de inmersión modelo A2G-60
Sonda di temperatura per condotti
Duct/immersion temperature sensor model A2G-60
/ i
mmersione modello A2G-60
GB
D
F
E
I
GB
Operating instructions model A2G-60 Page 3 - 12
D
Betriebsanleitung Typ A2G-60 Seite 13 - 22
F
Mode d'emploi type A2G-60 Page 23 - 32
E
Manual de instrucciones modelo A2G-60 Página 33 - 42
I
Instruzioni per l'uso modello A2G-60 Pagina 43 - 52
© 2009 WIKA Alexander Wiegand SE & Co. KG All rights reserved. / Alle Rechte vorbehalten.
®
WIKA
is a registered trademark in various countries.
®
WIKA
ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions! Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen! Zum späteren Gebrauch aufbewahren!
Lire le mode d'emploi avant de commencer toute opération ! A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo! ¡Guardar el manual para una eventual consulta!
Prima di iniziare ad utilizzare lo strumento, leggere il manuale d'uso! Conservare per future consultazioni!
2
WIKA operating instructions air2guide model A2G-60
40202798.02 08/2012 GB/D/F/E/I
Contents
Contents
1. General information 4
2. Safety 5
3. Specications 6
Design and function
4.
5. Transport, packaging and storage 9
6. Commissioning, operation 9
7. Maintenance and cleaning 12
8. Disposal 12
8
GB
40202798.02 08/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-60
3
1. General information
1. General information
The duct/immersion temperature sensor described in the operating instructions has been designed and manufactured using state-of-the­art technology. All components are subject to stringent quality and
GB
environmental criteria during production. Our management systems
are certied to ISO 9001 and ISO 14001.
These operating instructions contain important information on handling the instrument. Working safely requires that all safety instructions and work instructions are observed.
Observe the relevant local accident prevention regulations and general safety regulations for the instrument's range of use.
The operating instructions are part of the product and must be kept in the immediate vicinity of the instrument and readily accessible to skilled personnel at any time.
Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work.
The manufacturer's liability is void in the case of any damage caused by using the product contrary to its intended use, non-compliance
with these operating instructions, assignment of insuciently qualied skilled personnel or unauthorised modications to the
instrument.
The general terms and conditions contained in the sales documenta­tion shall apply.
Subject to technical modications.
Further information:
- Internet address: www.wika.de / www.wika.com www.air2guide.com
- Relevant data sheet: TE 62.90
4
WIKA operating instructions air2guide model A2G-60
40202798.02 08/2012 GB/D/F/E/I
1. General information / 2. Safety
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation which can result in serious injury or death if not avoided.
Information
... points out useful tips, recommendations and information
for ecient and trouble-free operation.
2. Safety
WARNING!
Before installation, commissioning and operation, ensure that the appropriate duct/immersion temperature sensor has been selected in terms of measuring range, design
and specic measuring conditions.
Non-observance can result in serious injury and/or damage to the equipment.
Further important safety instructions can be found in the individual chapters of these operating instructions.
2.1 Intended use
For measuring the temperature of gaseous media in heating, ventilation and air-conditioning systems
Designed for connection to control and display systems
In combination with a stem also suitable for measuring liquid media (e.g. in pipeline systems)
The instrument has been designed and built solely for the intended use described here, and may only be used accordingly.
GB
40202798.02 08/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-60
5
2. Safety / 3. Specications
The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use.
2.2 Personnel qualication
GB
Skilled personnel
Skilled personnel are understood to be personnel who, based on their technical training, knowledge of measurement and control technology
and on their experience and knowledge of country-specic regulations,
current standards and directives, are capable of carrying out the work described and independently recognising potential hazards.
Explanation of symbols
3. Specications
Electrical connection
Connection terminal, 3-pin (3-wire) Cable gland: One-way, M16 for cable with max. D = 8 mm
Power supply
DC 15 ... 24 V / AC 24 V ±10 %
Power consumption
Typically 0.35 W / 0.82 VA
Output
TRV 0 ... 10 V, min. load 5 kΩ (3-wire)
TRA 4 … 20 mA (2-wire)
6
WARNING!
Risk of injury if qualication is insucient!
Improper handling can result in considerable injury and damage to equipment.
The activities described in these operating instructions may only be carried out by skilled personnel who have
the qualications described below.
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant European directives.
WIKA operating instructions air2guide model A2G-60
40202798.02 08/2012 GB/D/F/E/I
3. Specications
Dimensions in mm
Insertion length L
Standard 192 mm
Mounting ange
Material PA6.6, colour black
Max. +130 °C
GB
Ingress protection
IP 65 per EN 60529 / lEC 529
For further specications see WIKA data sheet TE 62.90 and the order
documentation.
40202798.02 08/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-60
7
4. Design and function
4. Design and function
4.1 Description
Design
CE conformity:
GB
2004/108/EG Electromagnetic compatibility (EMC) 2002/95/EC RoHS (restriction of the use of certain hazardous substances in electrical and electronic equipment)
Accuracy @ 21°C
Typically ±1 % of measuring range
Scale ranges
Standard temperature setting: 0 … +50 °C to be set via jumper: -50 … +50 °C, -15 … +35 °C, -10 … +120 °C,
0 … +160 °C, 0 … +250 °C
Permissible temperature
Head temperature
-35 … +90 °C passive (Pt1000 and Ni1000)
-35 … +70 °C active (TRV and TRA)
Sensor sleeve Standard: -50 … +160 °C High temperature version: -50 ... + 260 °C
4.2 Scope of delivery
Cross-check the scope of delivery with the delivery note.
8
WIKA operating instructions air2guide model A2G-60
40202798.02 08/2012 GB/D/F/E/I
5. Transport, packaging ... / 6. Commissioning, operation
5. Transport, packaging and storage
5.1 Transport
Check the duct/immersion temperature sensor for any damage that may have been caused by transport. Obvious damage must be reported immediately.
5.2 Packaging
Do not remove packaging until just before mounting. Keep the packaging as it will provide optimum protection during trans­port (e.g. change in installation site, sending for repair).
5.3 Storage
Permissible conditions at the place of storage
Storage temperature: -20 ... +85 °C Protect the instruments from moisture and dust.
6. Commissioning, operation
Installation and mechanical connection
Protect measuring instruments from contamination, high temperature
changes and vibrations
In order to avoid any additional heating, the instruments must not
be exposed to direct solar irradiation while in operation.
The duct/immersion temperature sensor can be fastened directly
to the ventilation duct using either a mounting ange or screws.
GB
40202798.02 08/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-60
9
6. Commissioning, operation
Electrical connection
Connection diagram (selection) Pt1000/Ni1000 sensor
The instruments are designed to operate with safety extra-low voltage
(SELV). When wiring up the instruments, the technical specications for
GB
those instruments should be followed. Particularly for passive sensors,
e.g. Pt1000, etc., in a 2-wire conguration, the sensor lead resistance
should be taken into account. If necessary, this must be corrected in the connected electronics. Through self-heating, the measurement current
aects the measuring accuracy and should, therefore, not be above
1 mA.
In the case of a sensor with transmitter, as a rule, the transmitter should be operated in the middle of the measuring range, since deviations can occur at the range limits. The ambient temperature of the transmitter electronics should be kept constant. The transmitters must be operated with a constant power supply. The measuring range is altered by changing the positions of the jumper links (see connection diagram). The initial value of the new measuring range is then available after approx. 2 s.
Sensor Sensor Sensor
4-wire
red
red
40202798.02 08/2012 GB/D/F/E/I
white
2-wire 3-wire
10
white
brown
WIKA operating instructions air2guide model A2G-60
brown
green
white
white
6. Commissioning, operation
Scale range adjustment for a TRV sensor
Scale range adjustment
-50 ... +50 °C
-10 ... +120 °C
0 ... +50 °C
0 ... +160 °C
0 ... +250 °C
-15 ... +35 °C
Offset adjustment
Terminals
Screw terminals, max. 1,5 mm²
Cable entry
Single, M20 for cable of max. D = 8 mm Double, M20 for 2 cables of max. D = 7 mm
GB
40202798.02 08/2012 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-60
11
7. Maintenance and cleaning / 8. Disposal
7. Maintenance and cleaning
The duct/immersion temperature sensor is maintenance-free and oers
long service life provided it is handled and operated properly.
GB
Clean the instruments with a moist cloth (soap water).
Repairs must only be carried out by the manufacturer or appropriately
qualied skilled personnel.
8. Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an environmentally compatible way and in accordance with the country-
specic waste disposal regulations.
12
WIKA operating instructions air2guide model A2G-60
40202798.02 08/2012 GB/D/F/E/I
Inhalt
Inhalt
1. Allgemeines 14
2. Sicherheit 15
3. Technische Daten 16
Aufbau und Funktion
4.
5. Transport, Verpackung und Lagerung 19
6. Inbetriebnahme, Betrieb 19
7. Wartung und Reinigung 22
8. Entsorgung 22
18
D
40202798.02 08/2012 GB/D/F/E/I
WIKA Betriebsanleitung air2guide Typ A2G-60
13
1. Allgemeines
1. Allgemeines
Der in der Betriebsanleitung beschriebene Kanal-/Tauchtempe-
raturfühler wird nach dem aktuellen Stand der Technik konstruiert
und gefertigt. Alle Komponenten unterliegen während der Fertigung
strengen Qualitäts- und Umweltkriterien. Unsere Managementsy-
steme sind nach ISO 9001 und ISO 14001 zertiziert.
D
Diese Betriebsanleitung gibt wichtige Hinweise zum Umgang mit
dem Gerät. Voraussetzung für sicheres Arbeiten ist die Einhaltung
aller angegebenen Sicherheitshinweise und Handlungsanwei-
sungen.
Die für den Einsatzbereich des Gerätes geltenden örtlichen Unfall-
verhütungsvorschriften und allgemeinen Sicherheitsbestimmungen
einhalten.
Die Betriebsanleitung ist Produktbestandteil und muss in unmittel-
barer Nähe des Gerätes für das Fachpersonal jederzeit zugänglich
aufbewahrt werden.
Das Fachpersonal muss die Betriebsanleitung vor Beginn aller
Arbeiten sorgfältig durchgelesen und verstanden haben.
Die Haftung des Herstellers erlischt bei Schäden durch bestim-
mungswidrige Verwendung, Nichtbeachten dieser Betriebsanleitung,
Einsatz ungenügend qualizierten Fachpersonals sowie eigenmäch-
tiger Veränderung am Gerät.
Es gelten die allgemeinen Geschäftsbedingungen in den Verkaufs-
unterlagen.
Technische Änderungen vorbehalten.
Weitere Informationen:
- Internet-Adresse: www.wika.de / www.wika.com www.air2guide.com
- zugehöriges Datenblatt: TE 62.90
14
WIKA Betriebsanleitung air2guide Typ A2G-60
40202798.02 08/2012 GB/D/F/E/I
1. Allgemeines / 2. Sicherheit
Symbolerklärung
WARNUNG!
… weist auf eine möglicherweise gefährliche Situation hin, die zum Tod oder zu schweren Verletzungen führen kann, wenn sie nicht gemieden wird.
Information
… hebt nützliche Tipps und Empfehlungen sowie Infor-
mationen für einen ezienten und störungsfreien Betrieb
hervor.
2. Sicherheit
WARNUNG!
Vor Montage, Inbetriebnahme und Betrieb sicherstellen, dass der richtige Kanal-/Tauchtemperaturfühler hinsichtlich Messbereich, Ausführung und spezischen Messbedin­gungen ausgewählt wurde. Bei Nichtbeachten können schwere Körperverletzungen und/oder Sachschäden auftreten.
Weitere wichtige Sicherheitshinweise benden sich in den
einzelnen Kapiteln dieser Betriebsanleitung.
2.1 Bestimmungsgemäße Verwendung
Zur Temperaturmessung in gasförmigen Medien von Heizungs-, Lüftungs- und Klimaanlagen
Ausgelegt zur Aufschaltung an Regler- und Anzeigesystemen
In Verbindung mit einer Tauchhülse auch zur Messung in
üssigen Medien (z. B. Rohrleitungssysteme) geeignet
Das Gerät ist ausschließlich für den hier beschriebenen bestimmungs­gemäßen Verwendungszweck konzipiert und konstruiert und darf nur dementsprechend verwendet werden.
40202798.02 08/2012 GB/D/F/E/I
WIKA Betriebsanleitung air2guide Typ A2G-60
D
15
2. Sicherheit / 3. Technische Daten
Ansprüche jeglicher Art aufgrund von nicht bestimmungsgemäßer Verwendung sind ausgeschlossen.
2.2 Personalqualikation
WARNUNG!
Verletzungsgefahr bei unzureichender Qualikation!
D
Fachpersonal
Das Fachpersonal ist aufgrund seiner fachlichen Ausbildung, seiner Kenntnisse der Mess- und Regelungstechnik und seiner Erfahrungen
sowie Kenntnis der landesspezischen Vorschriften, geltenden Normen
und Richtlinien in der Lage, die beschriebenen Arbeiten auszuführen und mögliche Gefahren selbstständig zu erkennen.
Symbolerklärung
3. Technische Daten
Elektrischer Anschluss
Anschlussklemme, 3-polig (3-Leiter) Kabelverschraubung: Einfach, M16 für Kabel mit max. D = 8 mm
Hilfsenergie
DC 15 ... 24 V / AC 24 V ±10 %
Leistungsaufnahme
Typ. 0,35 W / 0,82 VA
Ausgang
TRV 0 … 10 V, min. Belastung 5 kΩ (3-Leiter)
TRA 4 … 20 mA (2-Leiter)
16
Unsachgemäßer Umgang kann zu erheblichen Personen­und Sachschäden führen.
Die in dieser Betriebsanleitung beschriebenen Tätigkeiten nur durch Fachpersonal nachfolgend
beschriebener Qualikation durchführen lassen.
CE, Communauté Européenne
Geräte mit dieser Kennzeichnung stimmen überein mit den
zutreenden europäischen Richtlinien.
WIKA Betriebsanleitung air2guide Typ A2G-60
40202798.02 08/2012 GB/D/F/E/I
Loading...
+ 36 hidden pages