WIKA A2G-55 User Manual [en, de, es, fr, it]

Operating instructions Betriebsanleitung Mode d'emploi Manual de instrucciones Instruzioni per l'uso
ECO dierential pressure transmitter model A2G-55
Transmetteur de pression diérentielle ECO, type A2G-55
Transmisor de presión diferencial ECO modelo A2G-55
Trasmettitore di pressione dierenziale ECO modello A2G-55
ECO dierential pressure transmitter air2guide E, model A2G-55
GB
D
F
E
I
GB
Operating instructions model A2G-55 Page 3 - 8
D
Betriebsanleitung Typ A2G-55 Seite 9 - 14
F
Mode d'emploi type A2G-55 Page 15 - 20
E
Manual de instrucciones modelo A2G-55 Página 21 - 26
I
Instruzioni per l'uso modello A2G-55 Pagina 27 - 32
2
WIKA operating instructions air2guide model A2G-55
40317650.01 09/2010 GB/D/F/E/I
Contents
Contents
1. General information 4
2. Safety 4
3. Description 4
Specications and intended use
4.
5. Installation 6
6. Commissioning / Electrical connections 6
7. Storage 7
8. Maintenance and cleaning 7
9. Repairs 7
10. Disposal 7
11. Dimensions 8
Warning!
This symbol warns you against actions that can cause injury to people or damage to the instrument.
GB
5
40317650.01 09/2010 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-55
3
1. General information / 2. Safety / 3. Description
1. General information
Please keep these operating instructions in a place where they will be
easily accessible and visible to all users. The information contained in
these installation and operating instructions has been compiled with
GB
care and is, to the best of our knowledge, accurate and correct. For additional information relating to your specic application please refer to:
Ocial website at www.air2guide.com
The appropriate data sheet
2. Safety
WARNING!
Electrical devices may only be installed and mounted by a
qualied electrician.
The modules may not be used in connection with devices
that directly or indirectly aect human health or safety or that
could endanger humans, animals or material assets.
Serious injuries and/or damage can occur should the appropriate regulations not be observed.
Only qualied personnel, who are familiar with the relevant country­specic regulations, should install and commission this ECO dier-
ential pressure transmitter.
3. Description
These operating instructions apply to the following model:
ECO dierential pressure transmitter
model A2G-55, data sheet SP 69.05
4
WIKA operating instructions air2guide model A2G-55
40317650.01 09/2010 GB/D/F/E/I
4. Specications and intended use
4. Specications and intended use
Accuracy
Linearisation error: ±1.0 % FS Measuring accuracy at 0 … +50 °C: ±3.0 % FS at -10 … +50 °C: ±5.0 % FS Typical overall error: ±2.0 % FS
Measuring ranges
0 … 250 Pa, 0 … 500 Pa, 0 … 750 Pa, 0 … 1000 Pa, 0 … 1250 Pa, 0 … 2500 Pa, 0 … 3750 Pa, 0 … 5000 Pa
Maximum pressure
0 … 250 to 0 … 750 Pa: 5 kPa 0 … 1000 to 0 … 5000 Pa: 5 x FS
Burst pressure
0 … 250 to 0 … 750 Pa: 10 kPa 0 … 1000 to 0 … 5000 Pa: 10 x FS
Operating temperature
Storage: -20 … +85 °C Operation: -10 … +50 °C
Ingress protection
IP 65 per EN 60529 / lEC 529
GB
Standards
CE conformity: 89/336/EEC Electromagnetic Compatibility 2002/95/EG RoHS (restriction of the use of certain hazardous
substances in electrical and electronic equipment)
40317650.01 09/2010 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-55
5
5. Installation / 6. Commissioning / Electrical connections
5. Installation
Protect measuring instruments from contamination, high tempera-
ture changes and vibrations
GB
In order to avoid any additional heating, the instruments must not be
exposed to direct solar irradiation while in operation.
The dierential pressure transmitter must be screw-tted on a suitable vertical surface. The instrument has to be mounted horizon-
tally using the enclosed mounting screws.
6. Commissioning / Electrical connections
Output signal
DC 0 … 10 V, 3-wire
optionally 4 … 20 mA, 2-wire
Supply voltage
DC 13 ... 32 V
Electrical connection
PG-gland M16
Screw terminals max. 1.5 mm²
Connection diagram
Output signal 4 … 20 mA, 2-wireOutput signal DC 0 … 10 V, 3-wire
Uv Out Gnd
6
Uv Out Gnd
Legend
Pin 1: Power supply (+) Pin 2: Output signal Pin 3: Ground
WIKA operating instructions air2guide model A2G-55
Loop
Legend
Pin 1: Loop + Pin 3: Loop -
40317650.01 09/2010 GB/D/F/E/I
7. Storage / 8. Maintenance and cleaning ... 10. Disposal
7. Storage
To protect the dierential pressure transmitters from mechanical
damage keep them in the original packaging until installation.
Storage temperature range: -20 ... +85 °C
Protect pressure measuring instruments from moisture and dust.
8. Maintenance and cleaning
Clean the instruments with a moist cloth (soap water).
9. Repairs
Repairs must only be carried out by the manufacturer or appropriately qualied personnel. For further specications see WIKA data sheet
SP 69.05.
10. Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an
environmentally compatible way and in accordance with the country-
specic waste disposal regulations.
GB
40317650.01 09/2010 GB/D/F/E/I
WIKA operating instructions air2guide model A2G-55
7
12. Dimensions in mm
12. Dimensions in mm
GB
8
WIKA operating instructions air2guide model A2G-55
40317650.01 09/2010 GB/D/F/E/I
Inhalt
Inhalt
1. Allgemeines 10
2. Sicherheit 10
3. Beschreibung 10
Technische Daten und bestimmungsgemäße
4. Verwendung
5. Installation 12
6. Inbetriebnahme / Elektrische Anschlüsse 12
7. Lagerung 13
8. Wartung und Reinigung 13
9. Reparaturen 13
10. Entsorgung 13
11. Abmessungen 14
Warnung!
Dieses Symbol warnt Sie vor Handlungen, die Schäden an Personen oder am Gerät verursachen können.
11
D
40317650.01 09/2010 GB/D/F/E/I
WIKA Betriebsanleitung air2guide Typ A2G-55
9
1. Allgemeines / 2. Sicherheitshinweise / 3. Beschreibung
1. Allgemeines
Bewahren Sie die Betriebsanleitung an einem für alle Benutzer zugäng­lichen Ort auf. Die nachfolgenden Einbau- und Betriebshinweise haben wir nach bestem Wissen und Gewissen zusammengestellt. Sollten Sie Hinweise für Ihre spezielle Anwendung vermissen, können Sie weitere Informationen nden:
D
Über unsere Homepage www.air2guide.com
Die Bezeichnung des zugehörenden Datenblattes
2. Sicherheit
WARNUNG!
Einbau und Montage elektrischer Geräte dürfen nur durch eine Elektrofachkraft erfolgen.
Die Module dürfen nicht in Verbindung mit Geräten benutzt
werden, die direkt oder indirekt menschlichen, gesund­heits- oder lebenssichernden Zwecken dienen oder durch
deren Betrieb Gefahren für Menschen, Tiere oder Sachwerte
entstehen können.
Bei Nichtbeachten der entsprechenden Vorschriften können Körper­verletzungen und/oder Sachschäden auftreten.
Montieren und nehmen Sie den ECO-Dierenzdrucktransmitter nur in Betrieb, wenn Sie mit den zutreenden landesspezischen Richtli­nien vertraut sind und die entsprechende Qualikation besitzen.
3. Beschreibung
Diese Betriebsanleitung ist gültig für den Typ:
ECO-Dierenzdrucktransmitter
Typ A2G-55, Datenblatt SP 69.05
10
WIKA Betriebsanleitung air2guide Typ A2G-55
40317650.01 09/2010 GB/D/F/E/I
4. Technische Daten und bestimmungsgemäße Verwendung
4. Technische Daten und bestimmungsgemäße Verwendung
Genauigkeit
Linearitätsfehler: ±1,0 % FS Messgenauigkeit bei 0 … +50 °C: ±3,0 % FS bei -10 … +50 °C: ±5,0 % FS Typischer Gesamtfehler: ±2,0 % FS
Messbereiche
0 … 250 Pa, 0 … 500 Pa, 0 … 750 Pa, 0 … 1000 Pa, 0 … 1250 Pa, 0 … 2500 Pa, 0 … 3750 Pa, 0 … 5000 Pa
Maximaler Druck
0 … 250 bis 0 … 750 Pa: 5 kPa 0 … 1000 bis 0 … 5000 Pa: 5 x FS
Berstdruck
0 … 250 bis 0 … 750 Pa: 10 kPa 0 … 1000 bis 0 … 5000 Pa: 10 x FS
Zulässige Temperatur
Lagerung: -20 … +85 °C Betrieb: -10 … +50 °C
Schutzart
IP 65 nach EN 60529 / lEC 529
D
Normen und Standards
CE-Konformität: 89/336/EWG Elektromagnetische Verträglichkeit 2002/95/EG RoHS (Beschränkung der Verwendung bestimmter gefähr­licher Stoe in Elektro- und Elektronikgeräten)
40317650.01 09/2010 GB/D/F/E/I
WIKA Betriebsanleitung air2guide Typ A2G-55
11
Loading...
+ 25 hidden pages