WIKA 532.53+8xx User Manual [en, de, fr]

Operating Instructions Betriebsanleitung Instructions d'utilisation
Pressure gauges Model 5 per directive 94/9/EC (ATEX) with inductive alarm sensors Model 831
Druckmessgeräte Typ 5 nach Richtlinie 94/9/EG (ATEX) mit Induktiv-Grenzsignalgeber Typ 831
Manomètres Type 5 selon directive 94/9/EG (ATEX) avec seuil d'alarme inductif Type 831
II 2 GD c
GB
F
Model 532.53.160 per ATEX with inductive alarm sensors Model 831.12
GB
Operating instructions Model 5 per ATEX with Model 831 Page 1-22
Betriebsanleitung Typ 5 nach ATEX
mit Typ 831 Seite 23-42
Instructions d'utilisation Type 5 selon ATEX
F
avec Type 831 Page 43-49
2 WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
2133086 08/2004 GB/D/F
Contents
Contents
Contents
1. Safety instructions 4
2. Description 4
3. Technical data and use in accordance with intended use 5
4. Alarm contacts 7
5. Commissioning 9
6. Maintenance and servicing / cleaning 9
7. Repairs 9
Enclosure 1: Declaration of conformity for Models 53X with inductive alarm sensors Model 831 10
Enclosure 2: EC-type examination certificate (gases) for slot-type initiators types SJ and SC
(WIKA-Model 831) 11-13
Enclosure 3: EC-type examination certificate (gases) for SN-sensors types NJ and SJ
(WIKA-Model 831-SN / S1N) 14-17
Enclosure 4: EC-type examination certificate (dust) for SN-proximity sensors types CB, CC, ... SJ
(WIKA-Model 831 and 831-SN / S1N) 18-22
GB
2133086 08/2004 GB/D/F
3WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
1. Safety instructions / 2. Description
1. Safety instructions
!
Caution
GB
The appropriate national safety regulations (i.e. VDE 0100 / EN 60 079-14 / EN 837-2) must be observed when installing, putting into operation and running these instruments.
T Do not work on gauge while under voltage
T Serious injuries and/or damage can occur should the appropriate
regulations not be observed
T Only appropriately qualified persons should work on these
instruments
2. Description
T The pressure gauges measure the absolute pressure by means of resilient
diaphragm measuring elements. The reference point is absolute pressure "zero".
T Themeasuring features follow the example of the standards EN 837-3 and
DIN 16 085
The built-in electrical alarm contacts are non-contact slot-type inductive proximity sensors, which are supplied from control units with circuits that are certified to be intrinsically safe. When the adjustable set points are reached, their output circuits will be opened or closed.
T As a standard slot sensors model 831 are used according to EC-type
examination certificate PTB 99 ATEX 2219 X (see enclosure 2) and ZELM 03 ATEX 0128 X (see enclosure 4)
T SN sensors models 831-SN and -S1N according to PTB 00 ATEX 2049 X
(see enclosure 3) and ZELM 03 ATEX 0128 X (see enclosure 4) are special designs with safety features (that are not relevant to explosion protection) for special applications
The connection values of the switches are in accordance with EN 60 947-5-6 ("NAMUR").
4 WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
2133086 08/2004 GB/D/F
3. Technical data and use in accordance with intended use
3. Technical data and use in accordance with intended use
Working pressure
Model 43X.50/30: Steady: full scale value
Fluctuating: 0.9 x full scale value Overpressure safety: see data sheet PM 05.02
Pressure connection
T According to the general technical regulations for pressure gauges,
respectively (i.e. EN 837-2 "Selection and installation recommendations for pressure gauges").
When screw-fitting the gauges the force required for sealing must not be applied through the case or terminal box but, using a suitable tool, only through the spanner flats provided for this purpose at the square of the connector.
Installation with open-end wrench
Temperature effect
GB
When temperature of the pressure element deviates from reference temperature (+20 °C): max. ±0.8 %/10 K of true scale value
IP Ingress protection
IP 54 per EN 60 529 / IEC 60 529 (with liquid filling IP 65)
2133086 08/2004 GB/D/F
5WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
3. Technical data and use in accordance with intended use
Operating Temperature
Ambient: -20 ... +60 °C
Attention: Footnote 1) under table 1 must be absolutely taken into account!
GB
Medium: see table 1 Attention! With gaseous substances the temperature may increase as a result of the compression temperature. In such cases the pressure change rate has to be slowed down resp. the permissible medium temperature has to be reduced.
Table 1: Permissible medium temperature (only mechanical part)
Ignition temperature of Permissible maximum medium temperature the ambient atmosphere (in the pressure system) (temperature class)
> 85 °C (T 6) +70 °C > 100 °C (T 5) +85 °C > 135 °C (T 4) +100 or +120 °C > 200 °C (T 3) +100 or +185 °C > 300 °C (T 2) +100 or +200 °C > 450 °C (T 1) +100 or +200 °C
1) The permissible uppper ambient temperature for the electrical components is determined by the electrical connection values and the ignition temperature of the ambient gases, vapours and dusts. Therefore the maximum permissible ambient temperatures specified in the EC-type examination certificates for slot-type sensors and SN sensors must be observed as well. The lower of these two values is to be considered the maximum permissible ambient temperature!
2) The higher values apply only to special versions with higher permissible media temperatures.
2)
2)
2)
2)
Installation
T In order to ensure that with both models 53X.31 ... 34 pressure can be
safely and reliably vented through the case back, a distance of at least 25 mm has to remain free behind the case!
T In order to avoid any additional heating, the instruments must not be
exposed to direct solar irradiation while in operation!
T With filled versions the ventilating valve at the top of the case must be
opened prior to commissioning!
6 WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
2133086 08/2004 GB/D/F
3. Technical data ... / 4. Alarm contacts
Permissible vibratory stress at the mounting location
T As a matter of principle the instruments should only be mounted at locations
without vibratory stresses
T Where required, a decoupling from the mounting location can be achieved
e.g. by a flexible connecting line from the measuring point to the pressure gauge and mounting via a measuring instrument bracket.
T If this is not possible, the following limits must not be exceeded:
Dry gauges: Frequency range < 150 Hz (Models 532.XX) Acceleration < 0.7 g (7 m/s
2
)
Liquid-filled gauges: Frequency range < 150 Hz (Model 533.XX) Acceleration < 4 g (40 m/s2)
The liquid filling has to be checked on a regular basis. The liquid level must not drop below 75% of the gauge diameter.
4. Alarm contacts
EC-type examination certificates
T Standard version Model 831.XX
PTB 99 ATEX 2219 X (enclosure 2) and ZELM 03 ATEX 0128 X (enclosure 4) Depending on the number of switches and on the case diameter either Model SJ2-N... or Model SJ3.5-...-N... is used.
GB
T Safety pattern version Models 831.XX - SN or - S1N
PTB 00 ATEX 2049 X (enclosure 3) and ZELM 03 ATEX 0128 X (enclosure 4) Depending on the number of switches and on the case diameter either Models SJ 2-SN..., SJ 2-S1N..., SJ 3.5-SN.. or SJ 3.5-S1N... are used.
The built-in sensor type is stated on the product label of the pressure gauge.
Wiring details
T The electrical connections should be made by qualified electricians
T Connection of the switches via screw terminals in the terminal box
2
T Conductor cross section max. 1.5 mm
T The terminal assignment is stated on the connection plate at the
pressure gauge
2133086 08/2004 GB/D/F
7WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
4. Alarm contacts
The permissible limits for Ui, Ii and Pi of the intrinsically safe supply circuits depend on the sensor type. They can be taken from the corresponding EC-type examination certificates. (The sensor type is stated on the connection plate of the pressure gauge.)
GB
Suitable switch amplifiers are e.g.:
Circuit Sensor type Model designation EC-type exami- WIKA-
(s. Ex-certific.) Fa. Pepperl & Fuchs nation certificate Model
Model 1 standard KFD2-SR2-Ex1 PTB 00 ATEX 2080 904.31
Model 2 standard KFA6-SR2-Ex1 PTB 00 ATEX 2081 904.28
standard KFD2-SR2 Ex2 PTB 00 ATEX 2080 904.32
standard KFA6-SR2-Ex2 PTB 00 ATEX 2081 904.29 SN-sensors KFD2-SH-Ex1 PTB 00 ATEX 2042 904.33 SN-sensors KHA6-SH-Ex1 PTB 00 ATEX 2043 904.30
Electromagnetic compatibility
EMC according to EN 60 947-5-2. The instruments are to be protected against strong electromagnetic fields.
To set desired value indicator
The desired value indicators for the alarm contacts are adjustable over the adjustment lock in the window with the aid of adjustment key (included in deli­very; to be found on standard gauges on the outside edge of the junction box).
Desired value
indicators
(red set pointer)
Adjustment lock
Adjustment key removable
The desired value indicators for the alarm contacts are adjustable over the full range of the instrument. Switching points shall be set in the ranges between 10 % und 90 % of the scale, to ensure switching accuracy and long life of the mechanical measuring system.
8 WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
2133086 08/2004 GB/D/F
5. Commissioning ... 7. Repairs
5. Commissioning
During the commissioning process pressure peaks must be absolutely avoided. Open the shut-off valves slowly.
6. Maintenance and servicing / cleaning
The instruments require no maintenance or servicing. The indicator and switching function should be checked once or twice every 12 months. The instrument must be disconnected from the process to check with a pressure testing device.
The instruments should be cleaned with a damp cloth moistened with soap solution. For cleaning inside the instrument the mains power supply should be disconnected by means of the plug box. It must be ensured that all the parts are dry before the power is switched on again.
7. Repairs
Repairs are to be only carried out by the manufacturer or appropriately trained personnel.
For further details see WIKA data sheet AC 08.01 or PM 05.02.
GB
2133086 08/2004 GB/D/F
9WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
Enclosure 1:
y
g
GB
Konformitätserklärung
Richtlinie 94 / 9 / EG (ATEX)
Wir erklären in alle iniger Verantwortung, dass nachstehend genannte Produkte, Absolutdruckmess­geräte mit Plattenfeder, gemäß gültigem Datenblatt mit der Richtlinie übereinstimmen und dem Konformitätsbewertungsverfahren
'Interne Fertigungskontrolle'
unterzogen wurden.
WIKA-Typen / WI KA models
Die Unterlagen werden aufbewahrt unter der Aktennum mer 8000316354 bei der benannten Stelle 0032
TÜV NORD CERT Am TÜV 1
D-30519 Hannover
Die Geräte werd en gekennzeichnet mit
53X.5X / 53X.3X
Declaration of Conformit
Directive 94 / 9 / E C (ATEX)
We declare u nder our so le responsibi lity that th e products mentioned below, absol ute pressure gauges with diaphragm element, accordin g to the current data sheet correspon d with the directive and were subjected to the conformity assessment procedure
'Internal Control of Production'
Datenblätter / data sheets
PM 05.02
The dossier is retained under file nr. 8000316354 at the notified body 0032
TÜV NORD CERT Am TÜV 1
D-30519 Hannover
The gauges are marked with
.
II 2 GD c
Angewandte Normen: EN 13463-1 Gru ndlagen und Anforderungen EN 13463-5 Schutz durch konstruktive Sicher heit "c"
Die eingebauten baumustergeprüft. Die Nummern der Pr üfbeschei­nigungen und die Kennzeichnung
PTB 99 ATEX 2219 X bzw./resp. PTB 00 ATEX 2049 X II 2 G EEx ia IIC T6
Grenzsignalgeber 831
und/and
sind EG-
ZELM 03 ATEX 0128 X II 1 D Ex iaD 20 T...°C
Applied standards: EN 13463-1 Basic method and requirements EN 13463-5 Protection by constructional safety "c"
alarm contacts 831
The built-in Numbers of certificates and marking
are EC-type-certified.
WIKA Alexander Wiegand GmbH & Co. KG
Geschäftsbereich Prozessinstrumentierung / Division Process Instrumentation
Klingenberg, 30.10.2003
Armin Hawlik Werner Hünerth Leiter Logistikzentrum 2 Leiter Qualitätssicherung Mana
er Production and Logistics Quality Assurance Manager
2133086 08/2004 GB/D/F
10 WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
Enclosure 2:
GB
2133086 08/2004 GB/D/F
11WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
Enclosure 2:
GB
12 WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
2133086 08/2004 GB/D/F
Enclosure 2:
GB
2133086 08/2004 GB/D/F
13WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
Enclosure 3:
GB
14 WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
2133086 08/2004 GB/D/F
Enclosure 3:
GB
2133086 08/2004 GB/D/F
15WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
Enclosure 3:
GB
16 WIKA Operating instructions pressure gauges Model 5 with 831 per ATEX
2133086 08/2004 GB/D/F
Loading...
+ 36 hidden pages