Wieland 83.040.0103.0 Data Sheet

wieNET UMS 8-2G
wieNET UMS 8-2G
Industrial Ethernet Switch 10-port, unmanaged
83.040.0103.0
10 Port Gigabit / Fast Ethernet Switch
2 x 1000Mbd + 8 x 10/100Mbd Ports
Auto negotiation
Auto sensing
Auto crossing ( Auto-MDI(X) )
Redundant power supply possible
Supply voltage range 12 V . . . 48 V DC
Relay contact signals redundant supply fault
Dimension diagram wieNET UMS 8-2G
Technical Data
wieNET UMS 8-2G Order No. 83.040.0103.0
Ethernet
Ethernet
EthernetEthernet Gigabit Ethernet ports 2 x 1000Base-TX Ethernet / Fast Ethernet ports 8 x 10/100Base-TX Ethernet transfer rate 10/100 Mbps Ethernet connectors 10 x RJ45 Auto negotiation yes Auto sensing yes Auto crossing (MDI / MDI-X) yes Communication Full duplex / half duplex Ethernet standard IEEE 802.3 / 802.3u / 802.3x Fast Ethernet cable length (Twisted Pair) 100 m max. (Cat. 5 / Cat. 5e UTP) Ethernet cable length 100BASE-TX 100 m max. (Cat. 5 UTP) Ethernet cable length 10BASE-T 100 m max. (Cat. 3, 4, 5) Switching mode Store-and-forward switching mode Topology Line, star, mesh Power supply
Power supply
Power supplyPower supply Redundant power supply yes (P1, P2) Supply voltage range 12 . . . 48 V DC Connectors 1x 7-pin terminal block Power consumption 9.5 W max. Input current (at 24 V DC) 360 mA Input current max. 1.2 A Ambient conditions
Ambient conditions
Ambient conditionsAmbient conditions Operating ambient temperature -40 °C . . . +70 °C Humidity in operation 5 . . . 95 %RH (non-condensing) Storage temperature -40 ºC . . . +85 °C Mounting on DIN rail 35 mm (EN60715) Degree of protection IP40 MTBF (hours) 201,976 h
wieNET UMS 8----2G
wieNET UMS 8wieNET UMS 8
2G
2G2G
wieNET UMS 8-2G
Technical Data
wieNET UMS 8-2G Order No. 83.040.0103.0
Relay contact
Relay contact
Relay contactRelay contact
Current carrying capacity 1 A at 24 V Dimensions
Dimensions
DimensionsDimensions W x H x D (see Dimension diagram) 54 mm x 146 mm x 120 mm Weight
Weight approx. 1,000 g
WeightWeight Housing material
Housing material Aluminum
Housing materialHousing material Shock and Vibration
Shock and Vibration
Shock and VibrationShock and Vibration
Shock
Vibration
Connectors cross section
Connectors cross section
Connectors cross sectionConnectors cross section min. solid / stranded 0.2 mm² (AWG28) max. solid / stranded 1.5 mm² (AWG12) Strip length 7 mm Torque 0.4 Nm max. Approvals and Standards
Approvals and Standards
Approvals and StandardsApprovals and Standards
EMC
Safety cULus (UL 60950-1; CSA C22.2 No. 60950-1) Rail traffic EN50155, EN50121-3-2, EN50121-4 Display Elements
Display Elements
Display ElementsDisplay Elements
PWR1, PWR2 LED, green (Power input state)
Fault LED, red
Power 1 Power 2 PWR1 LED PWR2 LED Fault LED
0 0 off off off 0 1 off green red 1 0 green off red 1 1 green green off
RJ45-LED (Ports 1 . . . 8)
Gigabit LED (Ports 9 . . . 10)
Termin
Terminal connections
al connections
TerminTermin
al connectionsal connections 1 . . . 8 (Ethernet / Fast Ethernet ports) 8 x Ethernet (RJ45) 9 . . . 10 (Gigabit Ethernet ports) 2 x Ethernet (RJ45) PWR1, PWR2 (Redundant power supply)
Relay Relay contact (N.C.)
NC (opens when either PWR1 or PWR2 is missing)
MIL-STD-810F Impact acceleration & pulse duration, 40 g @ 11 ms MIL-STD-810F -
- Packed waveform: x: 2.4 Grms / y: 1.28 Grms / Z: 3.85.Grms
- Operating Random waveform: x: 0.740 Grms / y: 0.204 Grms / Z: 0.104 Grms
Emission: EN55022, EN61000-3-2, EN61000­3-3, FCC Part 15 Class A, ICES-003 Class A, ANSI C63.4 Immunity: EN61000-4-2, EN6000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN6000-4-8, EN61000-4-11
green = power input 1/2 connected and supplied off = power input 1/2 disconnected or unsupplied red = "Power inputs fault": one of the two power inputs is not connected/not supplied. off = both power inputs are connected and supplied (redundant supply)
LED green: off: link broken or no cable plugged blink: data transfer LED yellow: off: 10 M bit rate active on: 100 M bit rate active LED green: green: link up blink: transmitting / receiving data
F.G. Frame Ground V+ Supply voltage, positive terminal (9 V . . . 55 V DC) V- Supply voltage, negative terminal (0 V)
Relay contact is open when both PWR1 and PWR 2 are connected and supplied