wieNET UMS 8
wieNET UMS 8
Industrial Ethernet Switch
8-port, unmanaged
83.040.0001.0
8 Port Ethernet Switch
Auto negotiation
Auto sensing
Auto crossing ( Auto-MDI(X) )
Redundant power supply possible
Supply voltage range 9 V . . . 48 V DC
Dimension diagram wieNET UMS 8
Technical Data
wieNET UMS 8 Order No. 83.040.0001.0
Eth
Ethernet
ernet
EthEth
erneternet
Ethernet ports 8 x 10/100Base-TX
Ethernet transfer rate 10/100 Mbps
Ethernet connectors 8 x RJ45
Auto negotiation yes
Auto sensing yes
Auto crossing ( Auto-MDI(X) ) yes
Communication Full duplex / half duplex
Ethernet standard IEEE 802.3 / 802.3u / 802.3x
Ethernet cable length (Twisted Pair) 100 m max.
Switching mode Store-and-forward switching mode
Topology Line, star, mesh
Power supply
Power supply
Power supplyPower supply
Redundant power supply yes (P1, P2)
Supply voltage 9 . . . 48 V DC
Connectors 1x 5 pin terminal block
Power consumption 5.5 W max.
Input current (at 24 V DC) 200 mA
Input current max. 350 mA
Ambient conditions
Ambient conditions
Ambient conditionsAmbient conditions
Operating ambient temperature -10 ° C . . . +70 °C
Humidity in operation 5 . . . 95 %RH (non-condensing)
Storage temperature -40 ºC . . . +85 °C
Mounting on DIN rail 35 mm (EN60715)
Degree of protection IP40
MTBF (hours) 568,842 h
Dimensions
Dimensions
DimensionsDimensions
W x H x D (see Dimension diagram) 45 mm x 90 mm x 80 mm
Wieland Electric GmbH, Brennerstr. 10–14, D - 96052 Bamberg Type: wieNET UMS 8
www.wieland-electric.com Rev.: 03/2010 – Page 1 of 2
wieNET UMS 8
wieNET UMS 8wieNET UMS 8
wieNET UMS 8
Technical Data
wieNET UMS 8 Order No. 83.040.0001.0
Weight
Weight approx. 270 g
WeightWeight
Housing material
Housing material Aluminum
Housing materialHousing material
Shock and Vibration
Shock and Vibration
Shock and VibrationShock and Vibration
Shock
Vibration IEC60068-2-64 & ISTA Test Procedure 2A
Free fall ISTA Test Procedure 2A
Connectors cross section
Connectors cross section
Connectors cross sectionConnectors cross section
min. solid / stranded 0.2 mm² (AWG28)
max. solid / stranded 1.5 mm² (AWG12)
Strip length 7 mm
Torque
Approvals and Standards
Approvals and Standards
Approvals and StandardsApprovals and Standards
EMC
Safety cULus (UL 60950-1; CSA C22.2 No. 60950-1)
Display Elements
Display Elements
Display ElementsDisplay Elements
P1, P2 LED, green Power input state:
RJ45-LED LED green:
Terminal connections
Terminal connections
Terminal connectionsTerminal connections
1 . . . 8 (Ethernet ports) 8 x Ethernet (RJ45)
P1, P2
(Redundant power supply)
IEC60068-2-27 30g, 11 ms duration, 18
shocks (3 shocks for each axis)
0.6 Nm max.
Emission: EN55022, EN61000-3-2, EN610003-3, FCC Part 15 Class A, ICES-003 Class A,
ANSI C63.4
Immunity: EN61000-4-2, EN6000-4-3,
EN61000-4-4, EN61000-4-5, EN61000-4-6,
EN6000-4-8, EN61000-4-11
green = power connected
off = power off or not plugged
off: link broken or no cable plugged
blink: data transfer
LED yellow:
off: 10 M bit rate active
on: 100 M bit rate active
F.G. Frame Ground
V+ Supply voltage,
positive terminal (9 V . . . 48 V DC)
V- Supply voltage,
negative terminal (0 V)
Wieland Electric GmbH, Brennerstr. 10–14, D - 96052 Bamberg Type: wieNET UMS 8
www.wieland-electric.com Rev.: 03/2010 – Page 2 of 2
wieNET UMS 8
wieNET UMS 8wieNET UMS 8