White Rodgers 25M01A-101, 25M01A-100 Brochure

WHITE-RODGERS
25M SERIES GAS CONTROLS
PRODUCT INFORMATION
The 25M series gas control is a compact, multifunctional valve, with a direct-acting regulator ideal for use in pilot valve applications, thru-the wall heaters, RV heaters, gas clothes dryers, hearth prod­ucts, radiant heat systems, water heaters, cooking applications, agricultural heaters/ dryers, or other high-efficiency equipment.
The 25M valve, provided with a straight­in inlet, has various outlet configurations that, when coupled with the various pipe sizes available, make for easy adaptation to a given application.
Optional features, such as the inlet pressure tap, increase the flexibility in adapting this valve.
Available configurations include:
Single Solenoid
(for pilot valve applications)
Dual Solenoid, Valves in Series
(for applications requiring redundancy)
Dual Solenoid, Valves Independent
(for dual burner applications)
Split-Coil (for use with Hot Surface
Ignition systems)
Two-Stage (for applications requiring
both high-fire and low-fire settings)
general specifications
Standard Features
25M 25M
Appliance Manifold
XXCompact Size (3-13/32" x 2-1/2" - 2-19/32") X Split Coil
X Single Solenoid
X Dual Solenoid XXInlet Screen (protected from pipe damage) XXOutlet Screen (protected from pipe damage) XXField Adjustable Regulator XXReplaceable Operating coils without interrupting gas flow XXOutlet Pressure Tap X Ambient Temperature Rating: 32˚ to 155˚F
X Ambient Temperature Rating: 32˚ to 175˚F XXStraight Through Outlet (offset) X .110 x .010 Male Terminals
X 3/16" Male Tab Type Terminals
Optional Features
25M 25M
Appliance Manifold
X Orifice Holder Outlet XXRight/Left Angle Outlets
X Dual Outlets (Right-Angle-Left AND Right-Angle-Right or Straight Through
X Inverted Flare
X British Threads (Rp)
X Inlet Pressure Tap
X Natural to LP Regulator Selector (convertible)
X European Quiet-Type Solenoids
X Encapsulated Leads
X Ground Terminal
X Tamper Evident Regulator Seal
X Low Ambient Temperature Rating (-40˚ to 175˚F)
X High Capacity Model (60 KBTU Natural Gas)
X Two-Stage Operation (Right-Angle-Left or Right-Angle-Right Only)
Regulator Adjustment Range
Natural Gas: 2.8" to 4.0" W.C.
3.5" to 5.4" W.C.
LP Gas: 8.5" to 11.4" W.C.
9.0" to 12.0" W.C.
Conversion Kits
Range of Regulations
Natural Gas: 5,000 to 55,000 BTU/hr
5,000 to 65,000 BTU/hr —
Dual Solenoid Independent
LP Gas: 8,000 to 89,000 BTU/hr
8,000 to 104,000 BTU/hr —
Dual Solenoid Independent
Part Number
From Natural Gas to Regulated LP: F73-1493 Regulates between 9.0" to 12.0" W.C. From LP to Natural Gas: F73-1561 Regulates between 2.8" to 4.0" W.C. From Natural gas to LP: F69-2257 Blocks open the Regulator (Blocking Pin)
2
25M GAS CONTROL
PRODUCT INFORMATION
R-4080
Current Requirements
V oltage Frequency Single Coil Dual Coil, P arallel (total draw)
120 120 240 240
Model # Rated Volts Hertz Operating Mode Comments
25M01A
25M01B
12 24 24 24
120 120 120 120
DC
DC 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
general specifications
OPERA T OR(S) REQUIREMENT (AMPS)
.240 .120 .210 .175 .035 .030 .030 .025
SPLIT -COIL VERSIONS
60 60 50 50
Start Running Start Running
.480 .240 .420 .350 .070 .060 .060 .050
Glo-Bar On, Sensor Closed Glo-Bar Off, Sensor Open Glo-Bar On, Sensor Closed Glo-Bar Off, Sensor Open
SPLIT-COIL DUAL SOLENOID
REDUNDANT
25M01A
1" P.D. Capacity 2" P.D. Capacity Range of Regulation Ambient T emperature
Rating Outlet Pressure
Adjustment Range
Maximum Pressure: 1/2 PSI Agency Approvals: CSA Int’l all models
Pipe Sizes
Inlet: 3/8" or 1/4" NPT or British Threads (Rp)
Straight In
Outlet: 3/8", 1/4", 1/8" NPT or British Threads (Rp)
or Orifice Holder Right Angle Right (RAR), Right Angle Left (RAL), Offset Straight Through, or Right Angle Right and Left (Dual Outlet)
40K 60K
5 to 55K
32˚ to 155˚ F
2.8" to 4.0"
25M02
40K 60K
5 to 55K
32˚ to 175˚ F
2.8" to 4.0"
25M12
40K 60K
5 to 55K
-40˚ to 175˚ F
2.8" to 4.0"
DUAL SOLENOID
INDEPENDENT
25M03 25M13
30K/side*
35K/side+
5 to 65K
32˚ to 175˚ F
3.5" to 5.4"
30K/side*
35K/side+
5 to 65K
-40˚ to 175˚ F
3.5" to 5.4"
SINGLE SOLENOID
25M04
48K 70K
5 to 65K
32˚ to 175˚ F
2.8" to 4.0"
25M14
48K 70K
5 to 65K
-40˚ to 175˚ F
2.8" to 4.0"
* 60K with both solenoids energized
+ 70K with both solenoids energized
HIGH
CAP A CITY
25M72
52K 73K
25 to 85K
-40˚ to 175˚ F
2.8" to 4.0"
25M GAS CONTROL PRODUCT INFORMATION R-4080
3
Loading...
+ 5 hidden pages