Whirlpool WFW9640X Product Dimensions

Front-Loading Automatic Washer
30
" min.
(762 mm)
30
" min.
(762 mm)
28
" min.
(710 mm)
27
"
(686 mm)
52
1
/2"
(1335 mm)
32
1
/2"
(820 mm)
38
1
/4"
(970 mm)
27
"
(686 mm)
1
"
(25 mm)
1
"
(25 mm)
39
" min.
(990 mm)
48 in.2 *
(310 cm2)
3"* (76 mm)
3"* (76 mm)
1"* (25 mm)
24 in.
2
*
(155 cm2)
6"* (152 mm)
76"
(1930 mm)
27"
(686 mm)
1"
(25 mm)
1"
(25 mm)
5½"**
(140 mm)
311/2
"
(800 mm)
1
"
(25 mm)
4
"
(102 mm)
1
"
(25 mm)
9
"
(229 mm)
7
"
(178 mm)
7
"
(178 mm)
27
"
(686 mm)
3
"
(76 mm)
3
"
(76 mm)
34
" min.
(864 mm)
48 in.2 *
(310 cm
2
)
24 in.
2
*
(155 cm
2
)
1
"
(25 mm)
4
"
(102 mm)
311/2
"
(800 mm)
1
"
(25 mm)
27
"
(686 mm)
1
"
(25 mm)
1
"
(25 mm)
4
"
(102 mm)
18
" min
(457 mm)
31½"
(800 mm)
PRODUCT MODEL NUMBERS WFW9640X
Electrical: A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit serving only this appliance be provided.
Drain System Options
Standpipe drain system - wall or oor (views A & B)
The standpipe drain requires a minimum diameter standpipe of 2" (50 mm). The minimum carry-away capacity can be no less than 17 gal. (64 L) per minute. The top of the standpipe must be at least 30" (762 mm) high and no higher than 96" (2.4 m) from the bottom of the washer.
A B
OVERALL DIMENSIONS
Washer dimensions
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable.
Custom undercounter installation-washer only
Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 30" (762 mm) above the oor.
Floor drain system (view D)
The oor drain system requires a siphon break that may be purchased separately. See “Tools and Parts.” The siphon break must be a minimum of 28" (710 mm) from the bottom of the washer. Additional hoses might be needed.
C
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
A. Side view - closet or conned area B. Closet door with vents
For cabinet installation, with a door, the minimum ventilation openings in the top are required.
A. Recessed area B. Side view - closet or conned area
D
* Required spacing
** For venting out the side, 1" (25 mm) spacing is allowed.
Ref. 461970256991
03/2011