30" (76.2 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
7
/8" (70.8 cm) max. depth
WFG540H0A
WFG720H0A
WFG710H0A
WFG540H0E
WFG714HLA
WFG715H0E
Type of Gas
Natural Gas:
• This range is factory set for use with Natural gas. See “Gas
Conversions” section. The model/serial rating plate is located on the
A
oven frame behind the top right side of the oven door has information
on the types of gas that can be used. If the types of gas listed do not
include the type of gas available, check with the local gas supplier.
LP gas conversion:
F
B
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different gas
without consulting the serving gas supplier. See “Gas Conversions”
E
D
section.
Gas Supply Line
• Provide a gas supply line if 3/4" (1.9 cm) rigid pipe to the range
location. A smaller pipe on longer runs may result in insuffient
gas supply. With LP gas, piping or tubing size can be 1/2" (1.3 cm)
minimum. Usually, LP gas suppliers deteremine the size and materials
used in the system. NOTE: Pipe-joint compounds that resist the
action of LP gas must be used. Do not use TEFLON tape.
IMPORTANT: Range must be level after installation. Follow
the instructions in the “Level Range” section. Using the cooktop
as a reference for leveling the range is not recommended.
* Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
** Front of door and drawer may extend further forward
depending on styling.
Electrical
Flexible metal appliance connector:
• If local codes permit, a new CSA design-certified, 4 to 5 ft (122
to 152.4 cm) long, 1/2" (1.3 cm)
or 3/4" (1.9 cm) I.D., flexible metal
appliance connector may be used for
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is
required. A time-delay fuse or circuit breaker is also recommended.
It is recommended that a separate circuit serving only this range be
provided.
connecting range to the gas supply line.
• A 1/2" (1.3 cm) male pipe thread is needed for connection to the
female pipe threads of the inlet to the appliance pressure regulator.
• Do not kink or damage the flexible metal tubing when moving the
range.
Rigid pipe connection:
The rigid pipe connection requires a combination
of pipe fittings to obtain an in-line connection to
the range. The rigid pipe must be level with the
range connection. All strains must be removed
from the supply and fuel lines so range will be level and in line.
• Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This
valve should be located in the same room but external to the range
opening, such as an adjacent cabinet. It should be in a location that
allows ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the range.
CABINET OPENING DIMENSIONS
B
C
D
†®
TEFLON is a registered trademark of E.I. Du Point De Nemours and Company.
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm)
countertop height.
IMPORTANT: If installing a range hood or microwave hood combination
above the range, following the range hood or microwave hoods
combination instructions for dimensional clearances above
the cooktop surface.
A freestanding range may be installed next to combustible walls with
zero clearance.
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet
is covered by not less than 1/4" (0.64 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
A. 18" (45.7 cm) upper side cabinet to countertop
B. 13" (33 cm) max. upper cabinet depth
C. 30" (76.2 cm) min. opening width
A
K
F
J
Because Whirlpool Corporation includes a continues commitment to improve our products,
we reserve the right to change materials and specifications without notice.
E
L
G
H
I
M
D. For minimum clearance to top of cooktop, see NOTE *.
E. 301/8" (76.5 cm) min. opening width
F. The shaded areas are recommended for installation of rigid gas pipe.
G. 11" (27.6 cm)
H. 17" (43.2 cm)
I. 2" (5.1 cm)
J. 41/2" (11.4)
K. 3" (7.6 cm) min. clearance from both sides of range to side wall or
other combustible material.
L. Grounded outlet
M. Cabinet door or hinges should not extend into the cutout.
Dimensions are for planning purposes only. For complete details, see
Installation Instructions packed with product. Specifications subject
to change without notice.
A. 27
with handle
B. 36" (91.4 cm) cooktop
height (max.) with leveling
legs screwed all the way in*
C. 467/8" (119.1 cm) overall
height (max.) with leveling
legs screwed all the way in*
D. 297/8" (75.9 cm) width
C
E. 257/16" (64.3 cm) depth.
Back of range to front
of cooktop**
F. Model/serial rating plate
(located on the oven frame
behind the top right side of
the oven door)
A. Gas supply line
B. Shutoff valve “open” position
C. To range
0553363B