Whirlpool WED85HEFBL, YWED85HEFC, WED92HEFC, WED85HEFW, WED77HEFW Dimension Guide

...
Electric Dryer
PRODUCT MODEL NUMBERS
WED7505F, WED75HEF, WED7740F, WED77HEF, WED8540F, WED85HEF, WED90HEF, WED92HEF
Dryer Dimensions
Front view:
383/4" Min.
39" Max.
Side view:
27"
Installation spacing for recessed area or closet installation
All dimensions show recommended and minimum spacing allowed.
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door,
oor moldings, and dryer venting.
■ Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
■ For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
■ Companion appliance spacing should also be considered.
Recommended installation clearances (dryer only):
3"
18" min.
(457 mm)
(76 mm)
48 in.2 min.
(310 cm
2
)
Back view:
NOTE: Most
installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”
(18 mm)
*Approx. measurement.
3
/4"*
Power supply
cord/cable
Water inlet
Vent
(Steam models
only)
3
14
/8"
61/2"
1
3
/2"*
(89 mm)
1
6
/8"*
29
7
/8"*
3"
24 in.2 min.
(155 cm2)
0" - 5"*
(0" - 127 mm)
0"–5"*
(0 mm–127 mm)
1"*
(25 mm)
1"
(25 mm)
(76 mm)
*0" (0 mm) spacing is allowed for straight-back venting only. For steam models only, inlet hose must not be kinked.
Minimum installation clearances (dryer only):
Front Sides Rear Top Recessed NA 0" (0 mm) 0" (0 mm)** 0" (0 mm) Closet NA 0" (0 mm) 0" (0 mm)** 0" (0 mm) Under
NA 1” (25 mm) 0” (0 mm)** 0” (0 mm)
Counter
**0" (0 mm) spacing is allowed for straight-back venting only.
Custom under counter installation:
W10868947A
10/2016
ELECTRICAL REQUIREMENTS
To supply the required 3- or 4-wire, single phase, 120/240 volt, 60 Hz, AC only electrical supply (or 3- or 4-wire, 120/208 volt electrical
supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.Do not use an extension cord.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or exible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
WARNING: To reduce the risk of re, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances. Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or exible metal vent shall be used for exhausting.
■ Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
■ Do not use plastic or metal foil vent.
Exhaust hoods:
Recommended Styles:
Louvered Hood
Acceptable Style:
Box Hood
The “Vent System Charts” provide venting requirements that will help achieve best drying performance.
Standard Vent System Chart
Number of 90° elbows
0
1
2
3
4
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Angled
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Long Vent System Chart
Number of 90° elbows
0
1
2
3
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Angled
hoods
160 ft. (48.8 m)
150 ft. (45.7 m)
140 ft. (42.7 m)
130 ft. (39.6 m)
Angled Hood
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and turns.
■ When using elbows or making turns, allow as much room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
Determine vent length and elbows needed for best drying performance:
■ Use the following “Vent System Charts” to determine type
of vent material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied in “Vent System Charts.”
Exhaust systems longer than those specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
4
To determine if your model has a long vent system, refer to the type code located on the serial number plate in the inner door well. Example: An electric model would be DALV (Long Vent) – ELE – XXXXXXX-XXX.
NOTE: For long vent systems, use of box/louvered hoods will improve venting, regardless of length.
The dryer must be connected to the cold water faucet using new inlet hoses (not supplied). Do not use old hoses.
Rigid metal
120 ft. (36.6 m)