Top Mount Refrigerator
®
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
LOCATION REQUIREMENTS
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 2316016ER
03-18-09
1
/
2
" (1.3 cm)
2" (5.1 cm)
To ensure proper ventilation for your refrigerator, allow for a 1⁄2" (1.3 cm) space on
each side. Allow 3" (7.5 cm) of space between overhead cabinets and refrigerator
top. Allow at least 1" (2.5 cm) between back of cabinet and the wall. If your
refrigerator has an ice maker, make sure you leave some extra space at the back for
the water line connections.
If you are installing your refrigerator next to a fixed wall, leave 2" (5.1 cm) minimum
on the hinge side (depending on your model) to allow for the door to swing open.
NOTE: Do not install the refrigerator near an oven, radiator, or other heat source, nor
in a location where the temperature will fall below 55°F (13°C).
E
overall
D
top of
cabinet
C
B
not incl.
handle
A
C
D
top of
cabinet
B
A
E
overall
Dimensions “D” and “E” include rollers
extended 3/4" (1.9 cm)
ER6AHKXS
ER8AHKXR
ER8AHMXR
W6RXNGFW
W8RXEGMW
W8RXNGMW
ER8YHMXS
Electrical: A 115-volt, 60-Hz, AC-only, 15or 20-amp fused, grounded electrical supply
is required. It is recommended that a separate
circuit serving only your refrigerator be
provided. Use an outlet that cannot be turned
off by a switch. Do not use an extension cord.
Water: Connect the ice maker to a cold water
line with water pressure between 30 and 120
psi (207 and 827 kPa).
IMPORTANT: The pressure of the water
coming out of a reverse osmosis system
going to the water inlet valve of the
refrigerator needs to be between 30 and 120
psi (207 and 827 kPa).
If a reverse osmosis water filtration system is
connected to your cold water supply, the
water pressure to the system needs to be a
minimum of 40 to 60 psi (276 to 414 kPa).
Model size "A" "B" "C" "D" "E"
14 cu.ft. 31-1/4" 28" 28-1/8" 62-3/8" 63"
W6RXNGFW (79.4 cm) (71.1 cm) (71.4 cm) (158.4 cm) (160 cm)
16 cu.ft. 29" 28" 28-1/8" 65-3/8" 66"
ER6AHKXS (73.7 cm) (71.1 cm) (71.4 cm) (166.1 cm) (167.6 cm)
18 cu.ft. 30-7/8" 28" 28-1/8" 67-3/8" 68"
ER8AHKXR (78.4 cm) (71.1 cm) (71.4 cm) (171.1 cm) (172.7 cm)
ER8AHMXR
ER8YHMXS
18 cu. ft. 29-1/8" 28" 28-1/8" 67-3/8" 68"
W8RX*GMW (74 cm) (71.1 cm) (71.4 cm) (171.1 cm) (172.7 cm)
Depth Cab. Width Door Width Cab. Height Overall Height