Whirlpool S 5505 WS, S 4505/1 WS, TGV 3411 SW, S 4505/2 WS, TGV 3411-1 SW INSTRUCTION FOR USE

4gb61231.fm5 Page 1 Friday, September 14, 2001 10:48 AM
TGV 3411 PRODUCT DESCRIPTION SHEET
BE
1.
Removable panstand grids
2.
Large burner
3-4-5.
Medium burners
6.
Large burner control knob
7.
Medium burner control knob
8.
Medium burner control knob
9.
Small burner control knob
Symbols
Shaded circle Tap closed
Large flame and star
Small flame Minimum opening or
Maximum opening/delivery and electric ignition
reduced delivery
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-clockwise to the large flame and star setting .
After the burner has ignited, keep the knob pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Notes:
Should particular local conditions of the delivered
gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The safety device of the burner shuts off the gas
supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc,).
5019 419 61231
Important
Improper use of the grids can result in damage to the hob: do not position the grids upside down or slide them across the hob.
Do not use: — Cast iron griddles or terracotta pots and pans. — Heat diffusers such as metal mesh, or any other
types.
Two burners simultaneously for one receptacle
(e.g. fish kettle).
Telescopic knobs
A particular mechanism makes it possible to raise the knobs about 1 cm, in order to clean the surface under them. After cleaning, put the knobs back in their original position.
Note:
Peel the plastic film off the metal knob insert.
4gb61231.fm5 Page 2 Friday, September 14, 2001 10:48 AM
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE:
If the distance “A“ between the wall cabinets is between 600 mm and 680 mm, the height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm. In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS (Methane) G 20 NATURAL GAS (Groningue)G 25 LIQUIFIED PETROLEUM GAS (Cylinder) G 30 LIQUIFIED PETROLEUM GAS (Cylinder) G 31
Type of gas used
G 20 20 mbar 4 gas 7.95 757 l/h 15.9 G 25 25 mbar 4 gas 7.37 818 l/h 14.7 G 30 28-30 mbar 4 gas 7.95 578 g/h 15.9 G 31 37 mbar 4 gas 7.95 568 g/h 15.9
Type of burner
large medium
large medium
large medium
large medium
Appliance model
Injector marking
128
94
128
94
85653.00
85653.00
Rated heat capacity Pcs-kW
3.00
1.65
2.78
1.53
1.65
1.65
Total rated heat capacity Pcs-kW
Rated consumption
286 l/h 157 l/h
308 l/h 170 l/h
218 g/h 120 g/h
214 g/h 118 g/h
Total rated consumption
Reduced heat capacity Pcs-kW
0.60
0.35
0.60
0.35
0.60
0.35
0.60
0.35
Gas pressure
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Air required for burning m
3
/h
Loading...