Whirlpool RH4830, RH4836 User Manual

0 (0)
Installation Instructions and
Use and Care Guide
IMPORTANT: Read and save
these instructions.
IMPORTANT:
Installer: Leave Installation Instructions with the homeowner.
Save Installation Instructions for local electrical inspector's use.
628013A/9763369
RH4830 Series RH4836 Series
www.whirlpool.com
Quick Reference
Table of Contents:
Pages
Before you start Electrical requirements Product dimensions Venting requirements Installation steps Use and Care Information Warranty Requesting Assistance
or Service
2
2
3
3 - 4
4 - 6
7 - 8
8
9- 10
30" (76.2 cm) and 36" (91.4 cm) Convertible Range Hood
2
Before you start...
Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the clearances specified.
Check the location where the range hood will be installed. The location should be away from strong draft areas, such as windows, doors, and strong heating vents.
Mobile home installation
The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the Standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local codes.
Important: Observe all governing codes and ordinances.
This is the safety alert symbol. This symbol alerts you to
potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING”. These words mean:
You can be killed or seriously injured if you don’t follow instructions.
DANGER
WARNING
Your safety and the safety of
others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
You can be killed or seriously injured if you don’t immediately
follow
instructions.
Tools and materials needed for installation:
WARNING — TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable Codes and Standards, including Fire Rated Construction. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
WARNING — To reduce the risk of fire, use only metal ductwork.
This unit must be grounded.
• flat blade screwdriver
• pliers
• drill
• ruler
• 1-1/4" (3.0 cm) drill bit
• 1/8" (or 3 mm) drill bit for pilot holes
• pencil
Parts supplied:
• aluminum mesh filter
• baffle plate (vented installations)
• 3-1/4" x 10" (8.3 x 25.4 cm) damper/vent connector
• parts bag
• 7" (17.8 cm) round adapter
• compass or 8" (20.3 cm) circle template
• metal snips
• keyhole saw
• saber saw
• duct tape
• 7" (17.8 cm) round damper if using 7" (17.8 cm) round vent system
Electrical requirements
Important: Observe all governing codes and ordinances.
It is the customer’s responsibility:
• To contact a qualified electrical installer.
• To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.
A separate ground wire must be used. It is recommended that a qualified electrician determine that the ground path is adequate.
A 120-volt, 60-Hz, AC-only, fused electrical system is required. A separate 15-amp circuit is recommended.
Do not ground to a gas pipe. Check with a qualified electrician if
you are not sure range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPORTANT: Save Installation Instructions for electrical inspector’s use.
The range hood must be connected with copper wire only.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed copper cable. A U.L.- or C.S.A.-listed strain relief must be provided at each end of the power supply cable. Wire sizes (COPPER WIRE ONLY) and connections must conform with the rating of the appliance as specified on the model/serial rating plate.
This hood is factory set for vented installations. For non-vented
installations, purchase Filter Kit No. 4396388 from your dealer.
Cabinets with recessed bottoms:
• 2, 2" (5.8 cm) wide filler strips. Length and thickness determined by recess dimensions.
• 4 wood screws or flat head machine screws with washers and nuts to attach filler strips.
For vented installations, you also need:
3
Product dimensions
Venting requirements
29-7/8" (75.9 cm) model: RH4830 35-7/8" (91.1 cm) model: RH4836
7-1/2"
(19.1 cm)
1-1/2"
(3.8 cm)
1/2"
(12.7 mm)
1"
(2.5 cm)
6"
(15.2 cm)
9"
(22.9 cm)
12"
(30.5 cm)
3/4"
(1.9 cm)
2"
(5.1 cm)
17-1/2"
(43.2 cm)
Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code Part 1 and C22.2 No. 0-M91 - latest edition** and all local codes and ordinances.
A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply cable (at the range hood and at the junction box).
In U.S. only: For power cord connected installations, a U.L.­listed range hood cord-connection kit MUST be used. Cord kit has not been evaluated for use in Canada.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
One Batterymarch Park Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575
Venting system must terminate to the outside.
Do not terminate the vent in an attic or other enclosed space.
Do not use four-inch (10.2 cm) laundry-type wall caps.
Do not use plastic vent. Vent system needed for installation
is not included.
Determine which outside venting method needs to be used. It is recommended that the vent system be installed before installing the hood.
NOTE: If a non-vented (recirculating) installation is desired, follow instructions on Page 5.
The length of the vent system and number of elbows should be kept to a minimum to provide efficient performance. The size of the vent system should be uniform. Do Not install two elbows together. Use duct tape to seal all joints in the vent system. Vent system can terminate either through the roof or wall. Use caulking to seal exterior wall or roof opening around exhaust hood. For the most efficient and quiet operation, it is recommended that the range be vented vertically through the
Figure 1
7" (17.8 cm) round or 3-1/4" x 10" (8.3 x 25.4 cm) through roof
roof cap
24" (61.0 cm) to 30" (76.2 cm) above cooking surface
Round vent: Use 7" (17.8 cm) round damper (purchased separately)
Vertical roof venting
wall cap
3-1/4" x 10"
(8.3 x 25.4 cm)
through the wall
Horizontal wall venting
7" (17.8 cm) round or 3-1/4" x 10" (8.3 x 25.4 cm) through the wall
24" (61.0 cm) to 30" (76.2 cm) above cooking surface
Figure 2
Recommended vent length
Use 3-1/4" x 10" (8.3 x 25.4 cm) with a maximum length of 50 ft (15.2 m) or 7" (17.8 cm) round vent with a maximum length of 60 ft (27.9 m) for vent system. For best performance, use no more than three 90° elbows. To calculate the length of system you need, add the equivalent feet (meters) for each vent piece used in the system. See the examples on the next page.
roof through 7" (17.8 cm) round vent system.
Figures 1 and 2 show common venting methods and what types of materials are needed.
1/2"
(12.7 mm)
Now start...
With range hood in kitchen.
Prepare hood location
4
3-1/4" x 10" (8.3 x 25.4 cm) vent system
Recommended standard fittings
Maximum length = 50 ft. (15.2 m)
1 - 90° elbow = 5 ft. (1.5 m) 8 ft. (2.4 m) straight = 8 ft. (2.4 m) 1 - wall cap = 0 ft. (0 m) Length of 3-1/4" x 10" (8.3 x 25.4 cm) system = 13 ft. (3.9 m)
3-1/4" x 10" (8.3 x 25.4 cm) 90° elbow = 5 ft. (1.5 m)
3-1/4" x 10" (8.3 x 25.4 cm) flat elbow = 12 ft. (3.7 m)
3-1/4" x 10" (8.3 x 25.4 cm) wall cap =
0 ft. (0 m)
2 ft. (0.6 m)
6 ft. ( 1.8 m)
wall cap
3-1/4" x 10" (8.3 x 25.4 cm) elbow
7" (17.8 cm) vent system
90° elbow
wall cap
Maximum length = 60 ft. (27.9 m)
1 - 90° elbows = 5 ft.
(1.5 m)
1 - wall cap = 0 ft.
(0 m)
8 ft. (2.4 m) straight = 8 ft.
(2.4 m) Length of 7" (17.8 cm) system = 13 ft.
(3.9 m)
Recommended standard fittings
6 ft. (1.8 m)
2 ft. (0.6 m)
3-1/4" x 10" (8.3 x 25.4 cm) to 7" (17.8 cm) =
4.5 ft. (1.4 m)
90° elbow = 5 ft. (1.5 m)
45° elbow =
2.5 ft. (0.8 m)
3-1/4" x 10" (8.3 x 25.4 cm) to 7" (17.8 cm) 90° elbow = 5 ft. (1.5 m)
7" (17.8 cm) wall cap = 0 ft. (0 m)
Slide cardboard or hardboard under range before moving range across floor to prevent damaging floor covering.
Cover countertop, cooktop or set-in range with a thick, protective covering to prevent damaging them.
1.
Disconnect and move freestanding range from cabinet opening to provide easier access to upper cabinet and rear wall. Put a thick, protective covering over cooktop, set-in range or countertop to protect from damage or dirt.
2.
Determine which venting method (roof or wall venting or non-venting) you need to use. This range hood is shipped for non­vented installation.
3.
If cabinet has recessed bottom, add wood filler strips on each side. Locate screws to attach filler strips in locations shown.
wood filler strips (recessed cabinet bottoms only)
cabinet bottom
wall
3"
(7.6 cm)
3"
(7.6 cm)
Prepare and install the hood
3-1/4" x 10" (8.3 x 25.4 cm)
RECTANGULAR VERTICAL
vent system
5
4.
From the diagrams below, select the diagram for your installation.
Vented installations: Cut the vent system and electrical wiring access holes as required. Either wiring hole can be used.
Non-vented installations: Cut only the one 1-1/4" (3.2 cm) dia. wiring access hole required. If wiring through the top, use location shown in VERTICAL vent systems. If wiring through the back, use location shown in HORIZONTAL vent system.
5.
Remove terminal box cover. Depending on your installation, remove either back or top wiring knockout.
6.
Remove the rectangular damper/vent connector from under the left side of hood. Set connector and screws aside for use if connecting to a rectangular vent system.
For vented installations, go to Step 7a.
For non-vented installations, go to Step 7e.
1-1/2" (3.8 cm)
5-1/2" (14 cm)
centerline
wall
5-1/4" (13.3 cm)
7-1/2" (19.1 cm)
Insert damper/vent connection through wall cutout and into vent
2" (5.1 cm)
1-1/4" (3.2 cm) dia. hole
3-1/4" x 10" (8.3 x 25.4 cm)
HORIZONTAL
vent system
1/8" (3.2 mm)
3-3/4" (9.5 cm)
centerline
cabinet
front
5-1/4" (13.3 cm)
7-1/2" (19.1 cm)
3/4" (1.9 cm)
1-1/4" (3.2 cm) dia. hole
7" (17.8 cm)
ROUND VERTICAL
vent system
5"
(12.7 cm)
centerline
wall
7-1/2" (19.1 cm)
2" (5.1 cm)
1-1/4" (3.2 cm) dia. hole
8" (20.3 cm) dia. hole
Excessive Weight Hazard
Use two or more people to move and install range hood.
Failure to do so can result in back or other injury.
WARNING
terminal box cover
7a.
For vented installations:
Insert the baffle plate into slot behind grille. The locator bumps should be at the top as shown.
Remove either top or rear rectangular vent knockout. If using round vent, remove both top rectangular and semi-circular knockouts.
7b.
Vertical rectangular vent: Attach the damper/vent connection with two screws as shown.
7d.
Vertical round vent: Fasten the round adapter to the hood with two screws as shown. Install round damper (purchased separately).
7e.
For non-vented
installations:
Check that the baffle plate has not been installed in slot behind grille. If it has, remove the baffle plate
7c.
Horizontal rectangular
vent: Attach damper/vent connection to back of hood and insert through the wall cutout and into the horizontal vent.
Note: If the wall cap is directly behind the vent connector, the dampers in the wall connector and cap MUST NOT interfere with each other. Remove the vent connector damper if they interfere.
bumps
baffle plate
6
Make electrical connection
Electrical Shock Hazard
Disconnect power before making electrical connections.
Connect ground wire to green ground screw in terminal box.
Failure to do so can result in death or electrical shock.
WARNING
15.
Depress both sides of the light lens until tabs disengage from slots in hood and remove lens.
Install two 40 watt (maximum) type A-15 appliance bulbs.
Reinstall light lens. Depress both sides of lens, insert tabs into slots and release.
16.
For non-vented installations: Grasp tab at front
center of filter. Push toward back to release filter from spring clips at front. Pull down then froward to remove aluminum mesh filter.
Install non-vented filter (purchased separately) by inserting into channel at back of compartment. Grasp tab and pull forward so that filter snaps under spring clips at front.
14.
Direct wiring:
Connect the white and black wires of the power supply cable to the white and black leads in the hood with twist-on connectors.
Connect the power supply ground wire to the green ground screw inside the terminal box.
Use caulking to seal wire opening. Replace terminal box cover.
Using a U.L.-listed power supply cord-connection kit (U.S. only):
Follow Power Cord Kit instructions for connecting wiring.
To get the most efficient
use from your new range
hood, read the “Use and
Care Information” section.
Keep your Whirlpool
Installation Instructions and
Use and Care Guide close
to range hood for easy
reference.
white
green ground
screw
ground wire
black
8.
Lift the range hood up under cabinet and determine final position. Mark on the underside of cabinet the location of the four keyhole mounting slots. Set range hood aside on a protected surface.
keyhole slot
front of hood
9.
Use 1/8" (or 3 mm) drill bit and drill 4 pilot holes as shown.
drill pilot hole
10. Remove the 4 hood
mounting screws from the parts bag and install
in pilot holes. Leave screw heads away from shim strips about 1/4" (6.4 cm)
11. If using direct wiring, make
sure power is disconnected, and pull about 12" (30 cm) of wire through wall or cabinet and into opening.
12. Lift range hood into final
position, feeding electrical wire through wiring opening. Position the range hood so that the large end of the keyhole slots are over the screws. Then push the hood toward the wall so that the screws are in the neck of the slots. Tighten mounting screws to cabinet, making sure mounting screws are in narrow neck of slots. Make sure that damper blade, if used, rotates up and down freely.
13. Connect ventwork to hood.
Seal joints with duct tape to make the secure and air tight.
Note: Damper/vent connector and round vent plate can be installed up to 1/2" (12.7 mm) on either side of hood center if ventwork is off-center. In extreme off-center
1/4"
(6.4 mm)
installations, one end of the vent connector may need to be trimmed to clear the electrical strain relief.