PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
VENTING REQUIREMENTS
RH2330XJ
RH2336XJ
RH2630XJ
Electrical: 120-volt, 60-Hz, AC-only, 15-amp. electrical
supply. Use copper wire only. A time-delay fuse or circuit
breaker and separate circuit is recommended.
®
Range Hood – 24" (58cm), 30" (76.2 cm), 36" (91.4 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10112419
02-13-08
23-7/8" (60.6 cm) – 24" (61.0 cm) model
29-7/8" (75.9 cm) – 30" (76.2 cm) model
35-7/8" (91.1 cm) – 36" (91.4 cm) model
7-1/2"
(19.1 cm)
2"
(5.1 cm)
1-1/2"
(3.8 cm)
1"
(2.5 cm)
1-1/2"
(3.8 cm)
6"
(15.2 cm)
9"
(22.9 cm)
12"
(30.5 cm)
3/4"
(1.9 cm)
3/8"
(9.5 mm)
17-1/2"
(44.5 cm)
3-1/4" x 10" (8.3 x 25.4 cm) vent system
3-1/4" x 10" (8.3 x 25.4 cm) vent system
Maximum length = 35 ft. (10.7 m)
1 - 90° elbow = 5 ft. (1.5 m)
8 ft. (2.4 m) straight = 8 ft. (2.4 m)
1 - wall cap = 0 ft. (0 m)
Length of 3-1/4" x
10" (8.3 x 25.4 cm) system = 13 ft. (3.9 m)
Note: Flexible vent is not recommended
3-1/4" x 10"
(8.3 x 25.4 cm)
90° elbow =
5 ft. (1.5 m)
3-1/4" x 10"
(8.3 x 25.4 cm)
flat elbow =
12 ft. (3.7 m)
3-1/4" x 10"
(8.3 x 25.4 cm)
wall cap =
0 ft. (0 m)
2 ft.
(0.6 m)
6 ft. ( 1.8 m)
wall cap
3-1/4" x 10"
(8.3 x 25.4 cm)
elbow
Maximum length = 35 ft. (10.7 m)
1 - 90° elbows = 5 ft.
(1.5 m)
8 ft. (2.4 m) straight = 8 ft.
(2.4 m)
1 - wall cap = 0 ft.
(0 m)
Length of 7"
(17.8 cm) system = 13 ft.
(3.9 m)
Note: Flexible vent is not recommended
6"
(15.2 cm) v
ent system
3-1/4" x 10"
(8.3 x 25.4 cm) to
6" (15.2 cm) =
4.5 ft. (1.4 m)
90° elbow =
5 ft. (1.5 m)
45° elbow =
2.5 ft. (0.8 m)
3-1/4" x 10"
(8.3 x 25.4 cm)
to 6" (15.2 cm)
90° elbow =
5 ft. (1.5 m)
6" (15.2 cm)
wall cap =
0 ft. (0 m)
elbow
wall
cap
6 ft. (1.8 m)
2 ft.
(0.6 m)
6"
(15.2 cm) v
ent system
36" (91.4 cm)
base cabinet
height
24" (61.0 cm ) min.
30" (76.2 cm)
suggested max.
bottom of hood to
cooking surface
13" (33 cm)
cabinet depth
18" (45.7 cm) min.
24" (61 cm)
suggested max.
bottom of cabinet
to cooking
surface
24" (61.0 cm) or
30" (76.2 cm) or
36" (91.4 cm)
min. cabinet
opening width
CABINET OPENING DIMENSIONS
Roof Venting Wall Venting
A
B
C
A. 6" (15.2 cm) round vent or a
(8.3 x 25.4 cm) vent through roof
B. Round vent: use 6" (15.2 cm) round
damper (purchased separately)
C. 18" (45.7 cm) to 24" (61.0 cm)
above cooking surface
D. Roof cap
D
3¹⁄₄" x 10"
A
B
C
A. 6" (15.2 cm) round vent or a
(8.3 x 25.4 cm) vent through wall
B. 3¹⁄₄" x 10" (8.3 x 25.4 cm) vent
through the wall
C. 18" (45.7 cm) to 24" (61.0 cm)
above cooking surface
D. Wall cap
3¹⁄₄"