Whirlpool RB275PXV1 Installation Instructions Manual

ELECTRIC BUILT-IN
(STARTING WITH 1982 MODELS)
Part No. 311509 Rev. B
l-1/4” MIN.
L
HOLE IN 0’ SUPPORT S FOR CABLI
JUNCTION BOX:
SEE NOTE 1
*FOR A 36” OPEN TOP OVEN
DOOR HEIGHT
**2B-l/2” MINIMUM
IF 2&5/B” IS AVAILABLE THE CUTOUT SHOULD BE MADE 2&5/0”
FIGURE 1 - Rough-In Dimensions
1. CARPENTRY
Refer to Figure 1 for the dimensions of the oven and the space necessary to receive the oven. The oven support surface may be solid plywood or similar material but the contact surface must be level from side to side and from front to rear. This surface is 2%” below the open door height.
NOTE 1: The oven support surface must be flush with the bottom of the cabinet cut out.
WARNING: TO AVOID DAMAGE TO CABINET AND/OR POOR BAKE PERFORMANCE, DO NOT BLOCK OVEN VENT.
EN
RFACE
3” MAX.
NOTE: Wire sizes and connections must conform with the fuse size and rate of the appliance in accordance with the National Electrical Code and local codes and ordinances. Do not use an extension cord.
B. The appliance should be connected to the fused discon-
nect (or circuit breaker) box through flexible armored or non-metallic sheathed cable. The flexible armored cable extending from the appliance should be connected directly to the junction box. The junction box should be located as shown in Figure 1 so that as much slack as possible remains in the cable between the box and the appliance so that it can be moved if servicing is ever necessary.
C. A suitable strain relief must be provided to attach the
flexible armored cable to the junction box.
2. ELECTRICAL REQUIREMENTS
D. Electrical Connection.
IMPORTANT: OBSERVE AU GOVERNING CODES
AND ORDINANCES
SAVE THESE INSTRUCTIONS FOR THE LOCAL
ELECTRICAL INSPECTOR’S USE
A. A three-wire or four-wire single phase 120/240 volt 60Hz
AC only electrical supply (or threewire or four-wire 1201206 volt if specified on nameplate) is required on a separate circuit fused on both sides of the line (time-delay fuse or circuit breaker is recommended). Do NOT fuse neutral. The fuse size must not exceed the circuit rating of the appliance specified on the nameplate.
It is the personal responsibility and obligation of the customer to contact a qualified installer to assure that the electrical installation is adequate and is in conformance with the National Electrical Code and local code
ordinances.
Electrical ground is required on this appliance. This appliance is equipped with copper lead wires. If the connection is made to aluminum house wiring, use only special connectors which are approved for joining copper and aluminum wires, in accordance with the National Electrical Code and local codes and ordinances.
This appliance is manufactured with a white neutral power supply wire and a frame-connected green ground wire.