Whirlpool HOB G16 S, ART 486/A /7-LH INSTRUCTION FOR USE

HOB G16 PRODUCT DESCRIPTION SHEET
HU
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
10.
Electric ignition button
Symbols
Operation of burners
To light one of the burners:
Press the relative knob and turn it anti-clockwise to the large flame setting .
At the same time, press the button with the star . The spark plug gives out a spark that causes the burner to ignite.
Once the burner is lit, keep the knob pressed for about 10 seconds.
If the burner fails to light, repeat the above steps.
Shaded circle
Large flame Maximum opening/ delivery
Small flame
Tap closed
Minimum opening or reduced delivery
Note:
Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The burner safety system serves to prevent the emission of gas if the flame should be extinguished accidentally (draughts, interruptions in gas supply, dousing with liquids, etc.).
5019 619 53321
DIMENSIONS OF COOKTOP AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CAT. II2HS3P/P
Type of gas used Type of
NATURAL GAS (Methane) G20
LIQUID PETROLEUM GAS
(Cylinder) G30 LIQUID
PETROLEUM GAS (Cylinder) G31
NATURAL GAS (Methane) G25.1
Type of gas used Appliance
G20 25 mbar 4 gas 7.30 695 l/h 14.6 G30 30 mbar 4 gas 7.30 531 g/h 14.6 G31 30 mbar 4 gas 6.35 453 g/h 12.7 G25.1 25 mbar 4 gas 7.30 809 l/h 14.6
burner
large medium small
large medium small
large medium small
large medium small
model
Injector m a r k i n g 100/mm
122
90 74
85 65 50
85 65 50
129
99 78
Rated h ea t capacity kW
3.00
1.65
1.00
3.00
1.65
1.00
2.62
1.43
0.87
3.00
1.65
1.00
Total rated heat capacity kW
Rated consumption
286 l/h 157 l/h
95 l/h
218 g/h 120 g/h
73 g/h
187 g/h 102 g/h
62 g/h
332 l/h 183 l/h 111 l/h
Reduced he at capacity kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated consumption
Gas Pressure mbar
min. rat. max.
20 25 33
24 30 36.5
24 30 36.5
20 25 33
Alimentazione elettrica: 230V - 50Hz
Air required for burning
3
m
/h
Loading...