1. Removable panstand grids
2-3. Medium burners
u
i
o
p
Q
4. Large burner
5. Small burner
6. Double crown burner
7. Medium burner control knob
8. Medium burner control knob
9. Double crown control knob
10. Large burner control knob
11. Small burner control knob
12. Electric ignition button
W
Symbols
Shaded circlexTap closed
Large
flame delivery
Small
flame or reduced delivery
Maximum opening/
À
Minimum opening
À
v
t
i
u
s
å
Operation of burners with safety
device and electric ignition
To light one of the burners:
x Press the relative knob and turn it anti-
clockwise to the large flame setting
x Atthesametime,pressthebuttonwiththe
x Once the burner is lit, keep the knob pressed
x Release the knob.
If the burner does not ignite, repeat the
operations described above.
Note:
− Should particular local conditions of the
.
star
å
The spark plug gives out a spark that causes
the burner to ignite.
for about 10 seconds.
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting
À
.
À
.
− The burner safety system serves to prevent the
emission of gas if the flame should be
extinguished accidentally (draughts, interruptions
in gas supply, dousing with liquids, etc).
− The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
− UK: replace the gas fitting with the one
supplied (this job must be done by a
qualified technician).
USING THE DOUBLE-RING BURNER
When using the double-ring burner, leave the
knob on the maximum setting (large flame
for at least five minutes after lighting before
selecting a lower setting.
À
)
DIMENSIONS OF COOKING HOB AND W ORKTOP
INJECTORS TABLE CATEGORY II2H3+
Type of gas Type of Injector Rated Rated Reduced
used burner marking heat consump- heat
capacity tion capacity
Pcs-kW Pcs-kW min. rat. max.
NATURAL large 128 3,00 286 l/h 0,60
GAS medium 94 1,65 157 l/h 0,35
(Methane) G 20 small 76 1,00 95 l/h 0,30
double crown 139 3,30 314 l/h 1,50
LIQUID large 85 3,00 218 g/h 0,60
PETROLEUM GAS medium 65 1,65 120 g/h 0,35
(Cylinder) G 30 small 50 1,00 73 g/h 0,30
double crown 92 3,30 240 g/h 1,50
LIQUID large 85 3,00 214 g/h 0,60
PETROLEUM GAS medium 65 1,65 118 g/h 0,35
(Cylinder) G 31 small 50 1,00 71 g/h 0,30
double crown 92 3,30 236 g/h 1,50
Gas pressure
17 20 25
20 28-30 35
25 37 45
Type of gas Appliance Total rated Total rated Air required
used model heat capacity consumption for burning
Pcs-kW m
G20 20 mbar 5 gas 10,6 1009 l/h 21,2
G30 28-30 mbar 5 gas 10,6 771 g/h 21,2
G31 37 mbar 5 gas 10,6 757 g/h 21,2
3