HOB 462 PRODUCT DESCRIPTION SHEET
ES IT
1. Removable panstand grids
2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
10. Electric ignition button
Symbols
Operation of burners with
electric ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame setting .
• At the same time, press the button with the
star .
The spark plug gives out a spark that causes
the burner to ignite.
If the burner does not ignite, repeat the
operation.
Shaded
circle
Large flame
Small flame
Tap closed
Maximum opening/
delivery
Minimum opening or
reduced delivery
Note:
- Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
- UK: replace the gas fitting with the one
supplied (this job must be done by a
qualified technician).
5019 619 61161
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES:In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
NATURAL GAS
(Methane) G 20
LIQUID
PETROLEUM GAS
(Cylinder) G 30
LIQUID
PETROLEUM GAS
(Cylinder) G 31
Type of gas
used
G 20 20 mbar 4 gas 7.30 695 l/h 14.6
G 30 28-30 mbar 4 gas 7.30 531 g/h 14.6
G 31 37 mbar 4 gas 7.30 521 g/h 14.6
Type of
burner
large
medium
small
large
medium
small
large
medium
small
Appliance
model
Injector
marking
128
94
76
85
65
50
85
65
50
Rated
heat
capacity
Pcs-kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated
heat capacity
Pcs-kW
Rated
consumption
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required
for burning
3
m
Gas pressure
/h