HOB 454 PRODUCT DESCRIPTION SHEET
NL
1. Removable panstand grids
2-3. Medium burners
4. Large burner
5. Small burner
Symbols
Shaded
circle
Large
flame
Small
flame
Tap closed
Maximum opening/
delivery
Minimum opening
or reduced delivery
The control knobs for the burners and the
electric ignition button are on the control
panel on the oven.
Operation of burners
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame setting .
• Simultaneously, hold a flame to the
relevant burner until it lights.
5019 619 61151
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: in case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY I2L
Type of gas
used
NATURAL GAS
(Methane) G 25
Type of gas
used
G 25 25 mbar 4 gas 7.80 863 l/h 15.6
Type of
burner
large
medium
small
Appliance
model
Injector
marking
129
108
78
Rated
heat
capacity
Pcs-kW
3.00
1.90
1.00
Total rated heat
capacity
Pcs-kW
Rated
consumption
332 l/h
210 l/h
111 l/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
0.60
0.35
0.35
min. rat. max.
20 25 30
Air required
for burning
3
m
Gas pressure
/h