HOB 220 DE AT PRODUCT DESCRIPTION SHEET
Operation of burners with safety device and electric ignition
To light one of the burners:
•Press the relative knob and turn it anticlockwise to the large flame setting .
•At the same time, press the button with the
star .
The spark plug gives out a spark that causes the burner to ignite.
•Once the burner is lit, keep the knob pressed for about 10 seconds.
•Release the knob.
If the burner does not ignite, repeat the operation.
1.Removable panstand grids
2-3. Medium burners
4.Large burner
5.Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
10. Electric ignition button
Symbols
Shaded
Tap closed
circle
Large flame |
Maximum opening/delivery |
Small flame
Minimum opening or reduced delivery
Note:
-Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation
with the knob turned to the small flame setting .
-The burner safety system serves to prevent the emission of gas if the flame should be extinguished accidentally (draughts, interruptions in gas supply, dousing with liquids, etc.).
For Austria only:
ÖVGW Directives G 1 and G 2 and local building regulations must be complied with.
5019 619 61711
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
|
|
|
|
|
|
|
|
(DE) CATEGORY II2ELL3B/P |
||||||
INJECTORS TABLE |
|
|
|
|
|
(AT) CATEGORY II2H3B/P |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|||
Type of gas used |
Type of |
Injector |
|
Rated |
Rated |
Reduced |
|
Gas pressure |
||||||
|
|
burner |
marking |
|
heat |
consumption |
heat |
|
|
|
|
|
||
|
|
|
|
|
capacity |
|
|
|
capacity |
|
min. |
rat. |
|
max. |
|
|
|
|
|
Pcs-kW |
|
|
|
Pcs-kW |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
large |
128 |
|
3.00 |
286 l/h |
0.60 |
|
|
|
|
|
|||
medium |
94 |
|
1.65 |
157 l/h |
0.35 |
17 |
20 |
|
25 |
|||||
(Methane) |
G 20 |
|
|
|||||||||||
small |
76 |
|
1.00 |
|
95 l/h |
0.30 |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
large |
138 |
|
3.00 |
332 l/h |
0.60 |
|
|
|
|
|
|||
medium |
106 |
|
1.65 |
183 l/h |
0.35 |
18 |
20 |
|
25 |
|||||
(Methane)* G 25 |
|
|
||||||||||||
small |
83 |
|
1.00 |
111 l/h |
0.30 |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUID |
|
large |
79 |
|
3.00 |
218 g/h |
0.85 |
|
|
|
|
|
||
PETROLEUM GAS |
medium |
58 |
|
1.65 |
120 g/h |
0.52 |
42.5 |
50 |
|
57.5 |
||||
(Cylinder) |
G 30 |
small |
46 |
|
1.00 |
|
73 g/h |
0.46 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUID |
|
large |
79 |
|
2.62 |
187 g/h |
0.85 |
|
|
|
|
|
||
PETROLEUM GAS |
medium |
58 |
|
1.43 |
102 g/h |
0.52 |
42.5 |
50 |
|
57.5 |
||||
(Cylinder) |
G 31 |
small |
46 |
|
0.87 |
|
62 g/h |
0.46 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
||||||||
Type of gas used |
Appliance model |
Total rated heat |
|
Total rated |
|
Air required for |
||||||||
|
|
|
|
capacity Pcs-kW |
|
consumption |
|
burning m3/h |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
G 20 20 mbar |
4G |
|
7.30 |
|
|
695 l/h |
|
|
14.6 |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
G 25 20 mbar |
4G |
|
7.30 |
|
|
809 l/h |
|
|
14.6 |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
G 30 50 mbar |
4G |
|
7.30 |
|
|
531 g/h |
|
|
14.6 |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
G 31 50 mbar |
4G |
|
6.35 |
|
|
453 g/h |
|
|
12.7 |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
* Not supplied in Austria