Whirlpool HOB 200 AN INSTRUCTION FOR USE

HO B 2 0 0 PRODUCT DESCRIPTION SHEET
NL
Removable panstand grids
1.
Medium burners
2-3.
Large burner
4.
Small burner
5.
Medium burner control knob
6.
Medium burner control knob
7.
Large burner control knob
8.
Small burner control knob
9.
Electric ignition button
10.
Symbols
Shaded circle Tap closed Large flame Maximum opening/delivery
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame setting .
At the same time, press the button with the star . The spark plug gives out a spark that causes the burner to ignite.
Once the burner is lit, keep the knob pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operation.
Small flame
Minimum opening or reduced delivery
Note:
Should particular local conditions of the delivered
-
gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The burner safety system serves to prevent
-
the emission of gas if the flame should be extinguished accidentally (draughts, interruptions in gas supply, dousing with liquids, etc.).
5019 619 01004/A
DIMENSIONS OF COOKING HOB AND WORKTOP
(mm)
NOTES: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2L3B/P
Type o f ga s u se d Type o f
NATURAL GAS (Methane) G25
LIQUID PETROLEUM GAS (Butane) G30 (Propane) G31
Type of gas used Appliance model Total rated heat
G25 25 mbar 4 gas 7.3 809 l/h 8,187 G30/G31 30 mbar 4 gas 7.3 531 g/h 30,94
burner
large medium small
large medium small
Injector marking
F3 126
T8 96
F1 72
87 65 50
Rated heat capacity kW
3.00
1.65
1.00
3.00
1.65
1.00
capacity kW
Rated consumption
332 l/h 183 l/h 111 l/h
218 g/h 120 g/h
73 g/h
Total rated consumption
Reduced heat capacity kW
0.60
0.35
0.30
0.60
0.35
0.30
Gas pressure (
min. rat. max.
20 25 30
25 30 35
Air necessary (m for the combustion
of 1 m
ELECTRIC SUPPLY: 230V - 50Hz
3
of gas
mbar)
3
)
Loading...