FRAMTID HGA5K PRODUCT DESCRIPTION SHEET
FR BE
1. Removable panstand grids
2-5. Medium burners
3. Large burner
4. Small burner
6. Triple crown burner
7. Small burner control knob
8. Large burner control knob
9. Triple crown burner control knob
10. Medium burner control knob
11. Medium burner control knob
Symbols
Operation of burners with safety
device and electric ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame and star
setting .
• At the same time, hold the knob down
until the burner ignites.
• After the burner has ignited, keep the knob
pressed down for about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the
operations described above.
Shaded
circle
Large flame
and star
Small flame
Note:
— Should particular local conditions of
the delivered gas make ignition of the
burner difficult, it is advisable to repeat
the operation with the knob turned to
the small flame setting .
— The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden draught,
an interruption in the gas delivery, boiling
over of liquids, etc.).
— The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
Tap closed
Maximum opening/delivery
and electric ignition
Minimum opening
or reduced delivery
5019 619 01356
HB G31
DIMENSIONS OF COOKING HOB AND
WORKTOP (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 680 mm, the height
“B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the cooktop, the
height “B” must be a minimum of 400 mm.
Before installing a hood above the cooktop please refer to the hood instructions, which
specify the correct distance. In case of installation of an oven under the cooktop, please
refer to the separate oven instructions.
INJECTORS TABLE CATEGORY II2E+3+
132
132
92
87
65
50
92
87
65
50
Nominal
heating
capacity
kW
3.30
3.00
1.65
1.00
3.30
3.00
1.65
1.00
3.30
3.00
1.65
1.00
3.30
3.00
1.65
1.00
Nominal heating
capacity kW
Nominal
consumption
314 l/h
286 l/h
157 l/h
95 l/h
365 l/h
332 l/h
183 l/h
111 l/h
240 g/h
218 g/h
120 g/h
73 g/h
236 g/h
214 g/h
118 g/h
71 g/h
Typ e o f
gas used
NATURAL GAS
(Methane) G20
NATURAL GAS
(Methane) G25
LIQUID
PETROLEUM GAS
(Cylinder) G30
LIQUID
PETROLEUM GAS
(Cylinder) G31
Typ e of g a s u sed
G20 20 mbar 3C - 1 R - 2 SR - 1 AUX 10.60 1009 l/h 9.52
G25 25 mbar 3C - 1 R - 2 SR - 1 AUX 10.60 1174 l/h 8.187
G30 28-30 mbar 3C - 1 R - 2 SR - 1 AUX 10.60 771 g/h 30.94
G31 37 mbar 1 R - 2 SR - 1 AUX 10.60 521 g/h 23.80
Typ e o f
burner
Triple crown
large
medium
small
Triple crown
large
medium
small
Triple crown
large
medium
small
Triple crown
large
medium
small
Appliance
model
Injector
marking
Y 115
H2 98
X 72
Y 115
H2 98
X 72
ELECTRIC SUPPLY: 230 V ~ 50 Hz
NB: To replace the injectors, refer to the “INSTRUCTIONS FOR USE” handbook,
“INSTALLATION” section. In this product, the triple crown burner has only one
injector (D), therefore the instructions given in point 6 do not have to be followed.
Reduced heat
capacity kW
FR BE
1.55
0.80
0.45
0.35
Total nominal
consumption
Gas pressure mbar
min. nom. max.
1.55
0.60
0.35
0.30
1.55
0.60
0.35
0.30
1.55
0.60
0.35
0.30
1.55
0.60
0.35
0.30
Air necessary (m
combustion of 1 m
17 20 25
20 25 30
20 28-30 35
25 37 45
3
) for the
3
of gas
IKEA of Sweden AB
SE - 343 81 Älmhult