Whirlpool HB G21 S INSTRUCTION FOR USE

FRAMTID HGA4K PRODUCT DESCRIPTION SHEET
FR BE
1. Removable panstand grids
2. Large burner 3-4. Medium burners
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
Symbols
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame and star setting .
At the same time, keep the knob pressed against the control panel until the burners ignites.
After the burner has ignited, keep the knob pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Shaded circle
Large flame and star
Small flame
Tap closed
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The safety device of the burner shuts off
the gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc.).
5019 619 01349
HB G21
DIMENSIONS OF COOKING HOB AND
WORKTOP (mm)
Note: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Reduc ed heat capacity kW
FR BE
0.80
0.60
0.45
0.35
0.35
0.30
0.60
0.60
0.35
0.35
0.30
0.30
0.60
0.60
0.35
0.35
0.30
0.30
0.60
0.60
0.35
0.35
0.30
0.30
Air required for burning m
98
72
98
72
Nominal heating capacity kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Nominal consumption
286 l/h 157 l/h
95 l/h
332 l/h 183 l/h 111 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
consumption
Type of gas used
NATURAL GAS
(Methane) G20
NATURAL GAS
(Groningue) G25
LIQUID PETROLEUM GAS
(Cylinder) G30
LIQUID PETROLEUM GAS
(Cylinder) G31
Type of gas used
G20 20 mbar 4 gas 7.30 695 l/h 9.52
G25 25 mbar 4 gas 7.30 809 l/h 8.187
G30 28-30 mbar 4 gas 7.30 531 g/h 30.94
G31 37 mbar 4 gas 7.30 521 g/h 23.80
Typ e o f burner
large medium small
large medium small
large medium small
large medium small
Model configuration
Injector marking
Y 115
H2
X
Y 115
H2
X
87 65 50
87 65 50
Nominal heating capacity kWTotal nominal
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Gas pressure
(mbar)
min. nom. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
3
/h