Whirlpool HB G11 S INSTRUCTION FOR USE

FRAMTID HGA4K PRODUCT DESCRIPTION SHEET
DE GB FR NL BE
1. Removable panstand grids 2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
10. Electric ignition button
Symbols
Shaded circle Tap closed
Large flame
Small flame
Maximum opening/
delivery
Minimum opening or reduced delivery
Operation of burners
To light one of the burners:
Press the relative knob and turn it anti-clockwise to the large flame setting .
At the same time, press the button with the star . The spark plug gives out a spark that causes the burner to ignite.
Once the burner is lit, keep the knob pressed for about 10 seconds.
If the burner fails to light, repeat the above steps.
5019 619 01342
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The burner safety system serves to prevent the
emission of gas if the flame should be extinguished accidentally (draughts, interruptions in gas supply, dousing with liquids, etc.).
For BELGIUM: replace the gas fitting with the one supplied (this job must be done by a qualified technician).
HB G11
DIMENSIONS OF COOKTOP AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used
NATURAL GAS
(Methane) G20
NATURAL GAS
(Groningue) G25
LIQUID PETROLEUM GAS
(Cylinder) G30
LIQUID PETROLEUM GAS
(Cylinder) G31
Type of gas used
G20 20 mbar 4 gas 7.30 695 l/h 9.52
G25 25 mbar 4 gas 7.30 809 l/h 8.187
G30 28-30 mbar 4 gas 7.30 531 g/h 30.94
G31 37 mbar 4 gas 7.30 521 g/h 23.80
Typ e o f burner
large medium small
large medium small
large medium small
large medium small
Model configuration
Injector marking
115
Y H2
98
72
X
Y
115
H2
98
X
72
87 65 50
87 65 50
Nominal heating capacity kWTotal nominal
Nominal heating capacity kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Nominal consumption
286 l/h 157 l/h
95 l/h
332 l/h 183 l/h 111 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
consumption
Reduc ed heat capacity kW
FR BE
0.80
0.60
0.45
0.35
0.35
0.30
0.60
0.60
0.35
0.35
0.30
0.30
0.60
0.60
0.35
0.35
0.30
0.30
0.60
0.60
0.35
0.35
0.30
0.30
Air necessary ( m3) for the combustion of 1 m3 of gas
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Gas pressure
(mbar)
min. nom. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
IKEA of Sweden AB SE - 343 81 Älmhult
Loading...