HB 463 B PRODUCT DESCRIPTION SHEET
IT ES PT GB
1.
Removable panstand grids
2-3-5.
Medium burners
4.
Large burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Medium burner control knob
Symbols
Operation of burners with electric
ignition
To light one of the burners:
• Press the relative knob and turn it anti-clockwise to
the large flame and star setting .
• At the same time, keep the knob pressed against the
control panel until the burner ignites.
• After the burner has ignited, keep knob pressed for
about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note
- Should particular local conditions of the delivered
gas make the ignition of the burner difficult, it is
advisable to repeat the operation with the knob
turned to the small flame setting .
Shaded
circle
Large
flame
Small
flame
Important
Improper use of the grids can result in damage to
the hob: do not position the grids upside down or
slide them across the hob.
Do not use:
- cast iron griddles or terracotta pots and pans
- heat diffusers such as metal mesh, or any other
types
- two burners simultaneously for one receptacle
(e.g. fish kettle).
UK: replace the gas fitting with the one
supplied (this job must be done by a qualified
technician).
Tap clos e d
Maximum opening/delivery
and electric ignition
Minimum opening or
reduced delivery
5019 619 01046
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II 2H 3+
Type o f g as
used
NATURAL GAS
(Methane) G20
LIQUID
PETROLEUM GAS
(Cylinder) G30
LIQUID
PETROLEUM GAS
(Cylinder) G31
Type o f g a s
used
G20 20 mbar 4 gas 7.95 757 l/h 15.9
G30 28-30 mbar 4 gas 7.95 578 g/h 15.9
G31 37 mbar 4 gas 7.95 568 g/h 15.9
Typ e o f
burner
large
medium
large
medium
large
medium
Appliance
model
Injector
marking
100/mm
128
94
85
65
85
65
Rated heat
capacity
kW
3.00
1.65
3.00
1.65
3.00
1.65
Total rated
heat capacity
kW
Rated
consumption
286 l/h
157 l/h
218 g/h
120 g/h
214 g/h
118 g/h
Total rated
consumption
Reduced heat
capacity
kW
0.60
0.35
0.60
0.35
0.60
0.35
ELECTRIC SUPPLY: 230 V - 50 Hz
Gas pressure mbar
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required
for burning
3
m
/h