Whirlpool FGP335BL2 User Manual

Page 1

A WARNING

ALL RANGES CAN
TIP
INJURY TO PERSONS
COULD RESULT
INSTALL ANTI-TIP
DEVICE PACKED
SEE INSTALLATION INSTRUCTIONS

Installation Instructions

IMPORTANT: Read and save
these instructions
IMPORTANT: Irrstaller: Leave Installation Instructions and
anti-tip bracket template with the homeowner,
Homeowner; Keep Installation Instructions
and anti-tip bracket template for future reference.
Save Installation Instructions for local
electrical inspector's use.
30" Freestanding
Gas
Range
h
Page 2

Before you start...

Proper installation is your responsibility. A qualified technician must install this range. Make sure you have everything necessary
for correct installation. It is the responsibility of the installer to comply with the installation clearances specified on the serial/rating plate. The serial/rating plate is located under the maintop.
Note: 30" min. when bottom of wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered with not less than No.28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.
36" min. clearance between the top
of the cooking platform and the bottom of an unprotected wood or metal cabinet.
Shaded area is recommended area for 120v outlet on rear wall and area for through-the-wall connection of gas pipe and shutoff valve.
Electrical and gas dimensions
Center of range.
Grounded electrical outlet
is required. See Electrical requirements.
ALL OPENINGS IN THE WALL OR FLOOR WHERE THE
RANGE IS TO BE INSTALLED
MUST BE SEALED.
Important; Observe all governing codes and
ordinances.
Check location where range will be
installed. The range should be located away from strong draft areas, such as windows, doors and strong heating vents or fans. The range should be located for convenient use in the kitchen. Recessed installations must provide complete enclosure of the sides and rear of range.
Proper gas
supply connection
must be available. See Gas supply requirements.
that are shown
must be used. Given
dimensions provide 0" clearance.
Both anti-tip brackets MUST be installed. Brackets attach to floor at back ot range to hold both rear leveling legs. For detailed instructions, see Panels B and C.
Cabinet
opening
dimensions
Recommended area for through-the-floor connection of pipe and shutoff valve.
Center of
range.
Mobile Home Installation
The installation of this range must conform to the Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD Part 280) or when such standard is not applicable, the Standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups), ANSI Z225.1-NFPA 501 A, — latest edition, or with local codes.
When this range is installed in a mobile home, it must be secured to the floor. Any method of securing the range is adequate as long as it conforms to the standards listed above.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
Batterymarch Park Quincy, Massachusetts 02269
** American Gas Association
1515 Wilson Boulevard
Arlington, Virginia 22209
WARNING: If the information in this manuai is not foiiowed exactiy, a fire or expiosion may resuit causing property damage, personai injury or death.
Do Not store or use
asoline or other
?
fl<
ammabie vapors and
iiquids in the vicinity of this or any other appiiance.
■ WHAT TO DO iF YOU SMELL
GAS
• Do Not try to iight any
appiiance.
• Do Not touch any eiectrical switch; Do Not use any phone in your buiiding.
• immediateiy coil your gas suppiier from a neighbor’s phone. Foiiow the gas suppiier’s instructions.
• if you cannot reach your gas suppiier, caii the fire department.
instaiiation and service must be performed by a quaiified instaiier, service agency or the gas
supplier.
A WARNING
Fire Hazard
Do Not obstruct the flow of combustion and ventilation air.
Personal Injury Hazard
To eliminate the risk of bums or fire, avoid installing cabinet storage above the cooking surface. If cabinets are already installed, reduce the hazard of reaching over a heated cooking surface by installing a range hood. The range hood should extend a minimum of 5 inches out from the bottom front of the cabinets.
Reaching over a heated cooking surface could result in a serious burn.
Electrical Shock Hazard
It is the custonner’s responsibility:
• To contact a qualifié electrical
installer.
• To assure that the electrical installation is adequate and in conformance with Notional Electrical Code, ANSI/NFPA 70 — latest edition*, and all local codes and ordinances.
Failure to do so could result in electrical shock or other personal injury.
A CAUTION
Property Damage
• Contact a qualified floor covering installer to check that the floor covering can withstand heat at least 90”F above room temperature.
• Use an insulated pad or 1/4" plywood under range if installing range over carpeting.
Failure to do so may result in damage to floor covering.
Tools and materials needed for installation:
• gas line shutoff valve
• L.P.-resistant pipe-
joint compound
• A.G.A. design-
certified flexible metal
connector (4-5 feet)
• flare union adapter for connection to pressure regulator (1/2" NPTx 1^" or 3/4" I.D.)
hammer
adjustable wrench
• electric drill
wood floor:
3/16" drill bit
concrete/ceramic floor:
3/16" carbide­tipped masonry drill bit
flat-blade screwdriver or 5/16-inch nut driver

Parts supplied for installation:

2 anti-tip brackets
4 screws
Panel A
Page 3

Gas supply requirements

Observe all governing codes
and ordinances
Testing at 1/2 psI (gauge)
The range must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 /2 psig (3.5 kPa).
Adjust leveling .
legs so there is at least
1 /8 inch between bottom of range and ' leveling legs.
i
1/8" min.
rr-n
T

A WARNING

Fire Hazard
• Range must be connected to a
regulated gas supply.
• L.P. gas supply must Not exceed a pressure of 14" water column. This must be checked by a qualified technician before Installing the range.
• Do Not use an open flame to test for leaks from gas connections.
• New, A.G.A. design-certified, flexible
gas line should be used when codes
permit.
Failure to follow these Instructions could result In a fire, explosion or personal Injury.
This installation must conform with
local codes and ordinances. In the absence of local codes, installations must conform with American Nationai Standard,
Nationai Fuei Gas Code ANSI Z223.1 — latest edition.**
B
seriai/rating piate are for elevations up to
2.000 feet. For eievations above 2,000 feet, ratings are reduced at a rate of 4% for each
1.000 feet above sea levei.
A.G.A. for NATURAL and L.P. gases with
appropriate conversion. The seriai/rating plate located under the cooktop has information for the type of gas that can be used. If this information does not agree with the type of gas available, check with the local gas supplier. See Panel C and back
cover for gas conversion instructions.
pipe to the range location. A smaller size pipe on long runs may result in insufficient gas supply. Pipe-joint compounds made for use with L.P. gas must be used. With L.P. gas, piping or tubing size can be 1 /2" minimum. L.P. gas suppliers usually determine the size and materials used on the system.
codes permit, a new A.G.A.design-certitied, 4 - 5 foot long, 1 /2" or 3/4" I.D., flexible metal
appliance connector is recommended for connecting this range to the gas supply line.
Do Not kink or damage the flexible tubing
when moving the range. A 1 /2-inch male pipe thread is needed for connection to pressure regulator female pipe threads.
MB to range
■ ■ The supply line shall be equipped with an approved shutoff valve. This valve should be located in the same room as the range and should be in a location that allows ease of opening and closing. Do Not block access to shutoff valve.
line, a combination of pipe fittings must be used to obtain an in-line connection to the range. All strains must be removed from the
supply and fuel lines so range will be level and in line.
Input ratings shown on the
This range is design-certified by
Provide a gas supply line of 3/4" rigid
If local
shutoff valve “open” position
to gas supply
If rigid pipe is used as a gas supply
H The inlet pressure must be a
minimum of 1 inch above the set pressure of the regulator, a maximum of 14 inches total inlet pressure.
Set Pressure: Natural Gas 4 Inches L.P. Gas 10 Inches
I Line pressure testing:
Testing above 1/2 psi (gauge)
The range and its individual shutoff valve
must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than
1/2 psig (3.5 kPa).

Electrical

Requirements

A WARNING

Electrical Shock Hazard
• Electrical ground Is required on this
appliance.
• Do Not ground to a gas pipe.
• Do Not modify the power supply cord plug. If It does not fit the outlet, have a proper outlet Installed by a qualified electrician.
• Do Not have a fuse In the neutral or grounding circuit. A fuse In the neutral or grounding circuit could result In an electrical shock.
• Do Not use an extension cord with this appliance.
• Check with a qualified electrician If you are In doubt as to whether the appliance Is properly grounded.
Failure to follow these Instructions could result In a fire, electrical shock or other personal Injury.
If codes permit and a separate grounding wire is used, it is recommended that a qualified
electrician determine that the
grounding path is adequate.
A 12CFvolt, 60-Hz, AC-only, 15-ampere, fused elecfricai supply is required. A time-deiay fuse or circuit breaker is recommended, it is recommended that a separate circuit serving oniy this appliance be provided.
Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are necessary. In addition to checking that the outlet provides 120-volt power and is correctly grounded, the outlet must be checked by a qualified electrician to see if it is wired with correct polarity.
The wiring diagram is found on a separate sheet in the literature package. The wiring diagram can also be found on the back of the range.

Recommended grounding method

For personal safety, this appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong, grounding­type wall receptacle, grounded in accordance with the National Electrical Code, ANSI/NFPA 70 — latest edition* and all local codes and ordinances. (See Figure
1.) If a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded, 3-prong wall receptacle installed by a qualified electrician.
3-prong grounding plug
■ 3-prong grounding-type
power supply cord
grounding prong
wall receptacle

Now start...

With range in kitchen.
I
protective film from range. Keep cardboard shipping base under range. Remove oven racks and shipping materials from inside oven.
■ Remove shipping materials, tape and
A
WARNING
Personal Injury Hazard
• To reduce the risk of tipping of the appliance, the appliance must be secured by properly Installed floor­mounted antl-tip brackets supplied with the range.
• Save these Installation Instructions. If range Is moved to a new location, the antl-tip brackets must be removed and reinstalled In the new location.
Electrical Shock Hazard
• Take special care when drilling holes Into the floor. Electrical wires or plumbing may be located beneath floor.
• Locate the electrical circuits that could be affected by the Installation of these brackets and turn off power to these circuits.
Failure to follow these Instructions may result In electrical shock or other personal Injury.
positioned exactly where the back and sides
of range wiii be iocated when instaiied.
if instaiiing range in a mobiie home, you MUST secure range to floor. Any method of securing range is adequate as iong as it conforms to the standards iisted in the Mobiie
Flome instaiiation instructions, Panei A.
"T ■ Use a pencii to mark the mounting screw hole iocations on the floor. Remove template.
A
CAUTION
Property Damage
• Contact a qualified Installer for the best procedure to drill mounting holes
through your type of floor covering.
• Before moving range across floor,
check that range Is on shipping base, or slide range onto cardboard or hardboard.
Failure to follow these Instructions may result In damage to floor covering.
^3 ■ To mount antl-tip bracket to wood floor, driii a
3/16" hoie, 1/2" deep, at each mounting screw location.
To mount antl-tip bracket to concrete or ceramic floor, use
a masonry drill bit to drill a 3/16" hole, 1 /2" deep, at each mounting screw location.
Panel B
Page 4
16. 19.
Numbers correspond to steps.
■ Place anti-tip
bracket on floor with turned-
up flange facing the front.
Line up holes in anti-tip bracket with holes drilled in floor. Use screws to attach bracket to floor. Repeat
turned-up flange
■ ■ Remove shipping base, cardboard or hardboard from under range. Remove storage
drawer. Carefully move range into position. Grasp rear of range and carefully try to tip
range forward. If range tips forward, leveling legs are NOT properly engaged in anti-tip
brackets. Remove and reposition braokets so leveling legs will fit properly under end flanges of brackets.
Place rack in
8
oven. Place level on rack, first side to side; then front to back to check that range is
level. If range is not level, adjust legs up or
down. If needed, pull range forward until rear leveling legs can be adjusted. Push
range back into position and check that
range is level.
Note: Oven must be level for satisfactory
baking conditions.
with right anti-tip bracket.

A WARNING

Fire Hazard
Do Not make connection too tight. The regulator Is die cast.
Overtightening may crack the regulator, resulting In a gas leak and possible fire or explosion.
All connections must be wrench­tightened.
manual shutoff
flexible connector
pressure regulator
■ Pull range forward to make gas connections. Assemble the flexible connector from the gas supply pipe to the pressure regulator, located on the lower right hand side on the back of the range, in this order: shutoff valve, 1 /2" flare union adapter, flexible connector, t /2" flare union adapter. Seal all openings in floor or wall wherever range is installed.
10
for use with Natural and L.P. gas to seal all gas connections. If flexible connectors are used, be certain connector is not kinked.
11b Open the shutoff valve in the gas supply line. Wait a few minutes for gas to move through the gas line.
1/2" flare union adapters
Use pipe-joint compound made
valve

A WARNING

Fire Hazard
Do Not use an open flame to test for leaks from gas connections.
Checking for leaks with a flame may result In a fire or explosion.
12
to test all gas connections for leaks. Bubbles around connections wiii indicate a leak. If a leak appears, shut off gas valve controls and adjust connections. Then check connections again. NEVER TEST FOR GAS
LEAKS WITH A MATCH OR OTHER FLAME.
Clean all detergent solution from range.
■ B Plug power supply cord into
grounded outlet.
Id
■ B Move range into final
position. Grasp rear of range and carefully try to tip range forward to check that both rear leveling legs are engaged in anti-tip brackets.
15
Electronic Ignition System — initial lighting and gas flame adjustments.
When the cooktop control knob is turned to
"LITE" position, the system creates a spark to light the burner. This sparking continues until the control knob is turned to the desired setting. When the oven control is turned to the desired setting, a glow bar heats up bright orange and Ignites the gas. No sparking occurs and the glow bar remains on while the burner operates.
16
operation of the cooktop
burners. Push in and turn
each control knob to "LITE"
position. The flame should light
within 4 seconds.
the “LITE” position after burner lights.
17
control knob to "HI" position. Check each cooktop burner for proper flame. The small inner cone should have a very distinct blue flame approximately 1 /2" long. The outer cone Is not as distinct as the inner cone.
18.
need adjusting for proper flame, remove burner grates and carefully liff up the maintop. Adjust the air shutter to the widest opening that will produce a sharp blue flame that does not lift or blow off of the burner. Repeat as necessary with each burner.
19
the control knob to the "LITE" position and then to the "LO" position. The low flame should be a minimum, steady, blue flame. To adjust the burner, remove the control knob and turn the adjustment screw in the center of the valve
stem. Check the adjustment by turning the control knob from "HI" to "LO" several times. The burner is properly adjusted when the low flame remains steady and the burner does not go out. Check each burner.
20.
oven screws at rear of oven bottom. Pull oven bottom rear up and remove front of oven bottom from oven front. Remove oven bottom. Remove burner baffle.
Check the operation of the oven burner.
Push in and turn temperature control knob counterclockwise to 300°F.
The oven burner should light In 50 - 60 seconds. This delay Is normal. The oven safety valve
requires a certain time before it will open and allow gas to flow.
• Do Not Insert any object Into the
• Do Not clean the area.
Failure to follow these Instructions could result In product damage.
B Use a brush and liquid detergent
Turn power supply on to range.
Check the
Do Not leave the knob In
After burner lights, turn
If burners
Push in and turn
Remove oven rack. Remove
A
openings of the protective shield that surrounds the Ignitor.
CAUTION
Product Damage
___________
21
for proper flame. This flame should
have a 1" long inner cone of bluish-
green, with an outer mantle of dark
blue, and should be clean and soft in character. No yellow tips, blowing or lifting of flame should occur.
22
needs to be adjusted,
locate the air shutter near
the center rear of the
oven burner. Loosen the
lock screw and adjust
the air shutter until the
proper flame appears.
Tighten screw.
Check the oven burner
If oven flame
orifice
hood
23. Replace the oven burner baffle,
oven bottom, oven racks and broiler drawer.
To get the most efficient use from your new range, read your Use and Care Guide. Keep instaiiotion
instructions and Guide close to the
range for easy reference.

Gas conversion

The serial rating plate, located under the
maintop, specifies the type of gas this range was set to use. Conversion should be done by a qualified installer.
Natural to L.P. gas
Aa Convert the pressure regulator. Do Not
remove the pressure regulator.
cap
1. Unscrew the cap from the pressure
regulator. Be sure spring stays in place.
2. Turn the cap over so the hollow end faces outward.
3. Replace the cap of the regulator. The letters L.P. should be visible on exposed end of the cap.
Convert surface burner valves.
B.
cooktop (shown in raised
position)
4 surface
burner
hoods
hood
NAT. GAS
increases gas
increases (lame size
(preset at factory for
rratural gas)
1. Lift and lock cooktop in up position.
2. Use 1 /2' wrench to turn hood clockwise until snug (approximately 2-1/2 turns).
Do Not overtighten.
W ■ Convert oven burner.
1. Remove oven bottom hold-down screws at rear of oven bottom. Pull up at rear, and remove front of oven bottom from oven front frame. Pull the oven bottom straight out of the oven. Remove burner baffle.
2. Use 1 /2" wrench to turn the hood clockwise (approximately 2-1/2 turns), until snug against the pin. Do Not overtighten.
3. Turn thermostat control knob to 300°F. The oven burner flame should be steady and approximately 1" long with no yellow or orange tips.
L.P. GAS
decreases gas decreases flame size
Panel C
Page 5
4. If air shutter needs adjusting, loosen air shutter set screw and adjust to obtain proper flame. This will normally be completely open for L.P. gas. Tighten air shutter set screw.
5. Replace oven baffle and oven bottom.
L.P. to Natural gas
Converting to natural gas should be done by
a qualified Installer.
Use a wrench to remove cap from pressure
regulator. Turn cap over so that the "Nat." side is up and replace cap and gasket on regulator.
Cooktop orifice hoods and oven orifice hood need to be loosened 2 to 2-1/2 turns counterclockwise to allow for proper gas flow. The flame adjustment for cooktop burners and oven burner would be the same as described in the installation steps (see Panel C). ■
Part No. 316002955/4372193 Rev, B

If range does not operate...

• Check that the circuit breaker is not tripped or the house fuse blown,
• Check that the power supply cord is plugged into wall receptacle.
• Check that the gas supply is turned on.
NOTE: Refer to Use and Care Guide for operating instructions and cleaning instructions.

For cleaning and maintenance...

If removing the range is necessary for
cleaning or maintenance, shut off gas supply to the range. Disconnect the gas and electric supply.
If the gas or electrical supply is inaccessible,
lift the range slightly at the front and pull the range out away from the wall. Pull the range out only as far as necessary to disconnect the gas and electric supply lines.
Remove the range to complete cleaning or maintenance.
Move range back into operating position.
Level the range. Connect gas line to range and check for leaks. Plug electric power supply cord into outlet. Make sure that rear legs are engaged in anti-tip bracket.

A WARNING

Personal Injury Hazard/Product Damage
Do Not step, lean or sit on the range or the door or drawers of the range.
Failure to follow this Instruction could result In personal Injury and/or product damage.
Benton Harbor, Michigan 49022

If yoti need assistance...

Check your Use and Care Guide for a toll
free number to call or call the dealer from whom you purchased this appliance. The dealer is listed in the Yellow Pages of your phone directory under “Appliances —
Household — Major — Service & Repair." When you call, you will need the range
model number and serial number. Both numbers can be found on the serial/rating plate located under the maintop.
Printed on recycled paper. 10% post consumer waste/
0
50% recovered materials.
Printed in U.S.A.
Loading...