Whirlpool DS603, DS603I Installation [RUS]

0 (0)

INSTALLATION INSTRUCTIONS

FOR PREFINISHED & INTEGRATED (SINGLE & DOUBLE) MODELS

(NOTE: FOR INTEGRA TED PANEL PREPARATION INSTRUCTIONS REFER T O SUPPLIED SHEET P/N 526610)

DOUBLE MODELS

SINGLE MODELS

P/N 526609C (page 1 of 8)

DA

MODELS

DD603 Pref nished

DD603I Integrated

MODELS

DS603 Pref nished

DS603I Integrated

NOTE TO THE INSTALLER

1.Read these Instructions completely and carefully.

2.Installation of this requires basic mechanical and electrical skills.

3.Be sure to leave these Instructions with the Customer.

4.At the completion of the installation, the Installer must perform Final Check List as per Section 11 of these Installation Instructions.

5.Remove all packaging materials supplied with the .

Before installing the , remove the house fuse or open the circuit breaker. Ensure all water connections are turned OFF. It is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Regulations.

NOTE TO THE CONSUMER

Keep these Installation Instructions with your User Guide for future reference. must be securely anchored before it is operated.

The MUST be installed to allow for future removal from the enclosure if service is required. The installer is responsible for the installation. Improper installation is not covered under the Warranty.

BEFORE YOU START - DOUBLE & SINGLE MODELS

PARTS SUPPLIED

DOUBLE MODELS (INTEGRATED & PREFINISHED)

INSTALLATION KIT P/N 526677

ADDITIONAL TOE KICK KIT SUPPLIED WITH

PREFINISHED MODELS

White Pref nished Toe Kick Kit P/N 526680 or Black Pref nished Toe Kick Kit P/N 526681

SINGLE MODELS (INTEGRATED & PREFINISHED)

INSTALLATION KIT P/N 526677

TOOLS NEEDED

Drill & No.2 Phillips Bit

Wooden Chopping Board

Tape Measure

No.2 Phillips Screwdriver

Spirit Level

Flat Screwdriver

Safety Glasses

Adjustable Wrench or M5 Socket

Utility Knife

50mm Hole Saw

Pencil

Side Cutting Pliers

Sandpaper

 

INSTALLATION PREPARATION

ELECTRICAL PREPARATION

A)The switched power outlet for the appliance should be installed in a cabinet or on a wall adjacent to

the under bench space in which the appliance is to be installed. Note: The power outlet must be accessible after installation.

B)The power outlet should be positioned between 150mm and 450mm from the cavity.

PLUMBING & DRAINAGE PREPARATION

A)A readily accessible valve must be installed in the water supply pipe.

B)If the supply pressure exceeds 960kPa, then a pressure limiting valve must be used.

C)Review Plumbing Options on pages 3-4. Choose a method that best suits your needs.

D)A Drain Hose extension Kit P/N 525798 will extend the drain hose(s) by 3.6m. The kit is available from the nearest Fisher & Paykel Authorized Service Agent.

CAVITY PREPARATION

A)If installing mutiple products side by side a minimum

2.5mm clearance must be maintained around the 's.

B)On corner installations, ensure that there is a gap

between the adjacent cabinetry (e.g.door knobs) and the sides of the open . A 12.7mm minimum gap is recommended.

C)Where the is installed under a bench

top, it is recommended that bare wood surrounding the is sealed with an oil based paint or polyurethane to prevent possible steam damage.

D)Ensure the cavity sides are plumb (vertical) as this will assist with leveling the .

E)Ensure the cavity provides suff cient material to secure the using the mounting tabs (refer to step 1, page 5). If there is nothing to screw to, add something. See page 3 or 4 for screw locations.

F)The services hole MUST be immediately adjacent to the

rear lower corner of the cabinetry. If not, the hoses will prevent the being pushed back into the cavity all the way. The hole can be located on either side depending on the location of the services.

P/N 526609C (page 2 of 8)

ELECTRICAL INFORMATION

POWER SUPPLY CORD

A)Care should be taken when the appliance is installed

or removed, to reduce the likelihood of damage to the power supply cord.

B)If the power supply cord is damaged, it must be replaced by the Manufacturer, Service Agent or a similarly qualif ed person, in order to avoid a hazard.

EARTHING INSTRUCTIONS

A)This appliance must be earthed. In the event of malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current.

Improper connection of the equipment-earthing conductor can result in a risk of electric shock. Check with a qualif ed electrician or service representative if you are in doubt as to whether the appliance is properly earthed.

B)This appliance is equipped with a power supply cord having an equipment-earthing conductor and a earthing plug. The power supply plug must be plugged into an appropriate outlet that is installed and earthed in accordance with all local Codes and Regulations.

Do not modify the power supply plug provided with the appliance - if it will not f t the outlet, have a proper outlet installed by a qualif ed electrician. Do not use an extension

Whirlpool DS603, DS603I Installation

DOUBLE MODEL

SERVICE'S SPECIFICATION

THE CAVITY

*

*For an Integrated

the product depth is specif ed

with an 18mm Integrated Door Panel thickness.

Water Connection

 

Recommended COLD

 

(Maximum 60°C)

 

3/4 " BSP (GB20)

 

to suit f at washer.

 

Water Pressure

 

Maximum 960kPa (139 p.s.i.)

 

Minimum Dynamic 30kPa (4.3 p.s.i.)

Drain Connection

 

Drain Hose Joiner to suit

 

19mm + 2mm waste tee.

 

Electrical Connection

NOTE: All depth measurements are taken from the front face of

230-240 VAC power outlet

the adjacent cabinetry.

9Amps Minimum.

 

Toe Kick Depth

Ensure the edges of the services hole are smooth or covered.

Prefinished

50-65mm.

 

Integrated

 

67mm less the Toe Kick Panel thickness (Minimum Panel thickness

using the supplied screws is 9mm).

Length of Services

 

Drain hose - 2250mm

 

Inlet hose - 1750mm

 

Power supply cord - 1965mm

 

NOTE: Services approximately exit product

189mm from left; 550mm from front;

793mm from top.

 

P/N 526609C (page 3 of 8)

PLUMBING OPTIONS

Option 1 and Standpipe 38mm with Air Gap.

NOTE: Pref nished Model is shown. There is no variation in plumbing between Pref nished products and Integrated products. Option 1 and 2 are the preferred options.