Whirlpool CAW21D2A1 Installation & Operation Manual

BEFORE YOU USE YOUR AIR CONDITIONER
Copy your Model and Serial Numbers here.. .
When you need service or call with a question, have this information ready:
Complete Model and Serial Numbers. To find Model and Serial Numbers remove the front panel (see pages 15-16). The numbers are located either on a plate attached to the lower front of the unit or on a label attached to the evaporator coil cover near the top of the unit.
SERIAL LABEL
SERIAL PLATE
L. Purchase date from sales slip.
Copy this information in the spaces below.
Keep this book, your warranty and sales slip
together in a handy place.
Model Number Serial Number Purchase Date Service Company and Telephone Number
It is your responsibility to make sure that your air conditioner:
l Has been properly installed. l Is the right size for the area you want
to cool.
l Is properly connected to electricity. l Is properly electrically grounded. l Is properly used only for the job it was
intended to do.
l Is not used by children or anyone not
able to operate it properly.
l Is properly maintained. l Also, remove energy label and buy guide.
Use damp cloth to take off any glue residue. Do not use a sharp instrument or any harsh or abrasive cleaners.
Energy Saving Tips
l Improve home insulation (seal doors,
windows, and close fireplace flue).
l Close blinds or drapes on sunny side of
house; add window awnings.
l Keep air filter clean. Don’t block air flow
with drapes or furniture.
l Ventilate attic (high temperature levels
add to normal cooling load).
l Try not to use heat producing appliances
during the hottest part of the day. Turn
lights,
radios,
televisions,
and
other
appliances off when not needed.
0 Keep heat registers and cool air returns
closed or blocked off so cooled air won’t escape.
l Use a vent fan in areas where cooking,
laundry, or bathing is done to pull out
extra heat and moisture near its source.
Contents
page
Before You Use Your Air Conditioner . . 2 Energy Tips
........................
2
Electrical Requirements
...............
3
Installation Instructions
...............
7 How to Start and
Use Your Air Conditioner . . . . . . . . . . 14
page
Cleaning and Caring for Your Air Conditioner
....................
16
Cooling Load Guide
.................
18
Self-Service Checklist
................
19
Service Information
.................
19
01986 Whirlpool Corporation
2
Electrical Requirements
For Your Air Conditioner
BELOW ARE ELECTRICAL PLUGVARIATIONS.CHOOSE THE ONE WHICH MATCHES THE AMPERE RATING OF YOUR UNIT. THE NUMBER OF AMPERES IS PRINTED ON THE SERIAL PLATE, ATTACHED TO THE FRONT OF THE
UNIT,
BEHIND THE FRONT PANEL (SEE PAGE 2).
Chart-A
PLUG TYPE
3-PRONG
GROUNDING PLUG
POWER SUPPLY
3-‘PRONG
GROUNDING
TYPE WALL
RECEPTACLE
CORD
SEE ELECTRICAL
REQUIREMENTS
A
n
For 115 volt models
with
serial
plate
amperes of 7.6 through
12.0
D
B
D
For 230 volt and 230/ 208 volt models with serial plate amperes up
-through 12.0
CE
Ir 230 volt and
Fo
2301
208 volt models with
serial
plate
amperes
up through 16.0
D
For 230 volt and 230/
208 volt models with serial plate amperes up through 24.0
A
n
ELECTRICAL REQUIREMENTS
For 115 volt models with serial plate amperes of
7.6 through 12.0 OBSERVE ALL LOCAL GOVERNING CODES
AND ORDINANCES
Do not, under any circumstances, remove the
power supply cord ground prong,
RECEPTACLE WIRING
RECEPTACLE WIRING should be at least as large as 14 gauge. Use copper wire only. It is the personal responsibility and obligation of the customer to provide proper and adequate receptacle wiring installed by a qualified electri­cian. OBSERVE NATIONAL ELECTRICAL CODE AND ALL LOCAL GOVERNING CODES AND ORDINANCES.
Electrical Requirements
A 115 volt (103.5 min., 126.5 max.) 60 hertz AC only, 15 ampere fused electrical supply is required (time delay fuse or time delay circuit breaker re­quired). It is recommended that a separate circuit, serving only this appliance, be provided. Do not use an extension cord.
Electrical Connection
Electrical Ground is Required on this Appliance RECOMMENDED GROUNDING METHOD
For your personal safety, this appliance must be grounded. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the
cord must be plugged into a mating 3-prong grounding type wall receptacle, grounded in accordance with the National Electrical Code and local codes and ordinances. If a mating wall
receptacle
is not available, it is the personal
responsibility and obligation of the customer to
have a properly grounded 3-prong wall receptacle installed by a qualified electrician. See Figure 1 on page 4..
Figure 1
3-PRONG
GROUNDING PLUG
‘ACLE
POWER-SUPPLY CORD
ALTERNATE GROUNDING METHOD
If changing and properly grounding the wall receptacle is impossible and where local codes permit (consult your electrical inspector), a temporary adapter may be plugged into the existing 2-prong wall receptacie to mate with the 3-prong power supply cord. See Figure 2. THIS,
HOWEVER, IS NOT RECOMMENDED.
If this is done, you must connect the grounded eyelet on the adapter to the wall receptacle
cover plate screw and from this same screw, you
must connect a separate copper ground wire
(~14 minimum) to a grounded cold water pipe.’
See Figure 2. Do not ground to a gas supply
pipe. Do not connect to electrical supply until
appliance is permanently grounded.
Figure 2
\
ELECTRICALLY / a
GROUNDED METAL
1’ -co\i
GROUND ASSEMBLY
(ATTACH TO GROUNDED.
3-PRONG GROUNDING
PLUG
WhLL RECEPTACLE
POWER SUPPLY CORD
*Cold water pipe must have metal continuity to
electrical ground and not be interrupted by
plastic, rubber or other electrically insulating connectors (including water meter or pump) without adding a jumper wire at these con­nections.
ELECTRICAL REQUIREMENTS
For 230 volt and 230/208 volt models with serial plate amperes up through 12.0
Refer to Chart B for specific wiring and receptacle information to be used.
OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES.
Do not, under any circumstances, remove the power supply cord ground plug.
ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE.
A three-wire, single-phase 60 hertz AC only electrical supply is required.
A separate electrical supply is required on a separately fused circuit. Do not fuse ground­neutral.
See Chart B for receptacle voltage require­ments,
proper fuse size, wire and wiring connections which must conform with rating of the appliance. Do not use an extension cord.
Chart-B
PLUG AND
RECEPTACLE
DATA
RECEPTACLE
VOLTAGE
(60 HERTZ
AC IN ALL
INSTANCES)
SERIAL PLATE
AMPERES
AECEPTACLE
MODEL WITH
SERIAL PLATE
OF 230 VOLTS
(207 MIN.253
MAX.)
UP
through
MODEL WITH
12.0
SERIAL PLATE
OF 230/209
VOLTS
(197.6 MIN-
253 MAX.)
I
RATING IN
I
SEE BELOW
AMPS
I
RECEPTACLE WIRING
RECEPTACLE WIRING should be at least as large as size shown on electrical Chart B. Use copper wire only. It is the personal responsibility and obligation of the customer to provide proper and adequate receptacle wiring installed by a qualified electrician. OBSERVE NATIONAL
ELECTRICAL CODE AND ALL LOCAL GOVERNING CODES AND ORDINANCES.
RECOMMENDED GROUNDING METHOD
For your personal safety, this appliance must be grounded. This appliance is equipped with a
power supply cord having a 3-prong grounding
plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong
grounding type wall receptacle, grounded in
accordance with the National Electrical Code
and local codes and ordinances. If a mating wall
receptacle is not available, it is the personal
responsibility and obligation of the customer to
have a properly grounded 3-prong wall receptacle
installed by a qualified electrician.
f?
ELECTRICAL
L&7
REQUIREMENTS
For 230 volt and 230/208 volt models with serial
plate amperes up through 16.0
Refer to Chart C for specific wiring and
receptacle information to be used.
OBSERVE ALL LOCAL GOVERNING CODES
AND ORDINANCES.
Do not, under any circumstances, remove the
power supply cord ground plug.
ELECTRICAL GROUND IS REQUIRED ON
THIS APPLIANCE.
A separate electrical supply is required on a separately fused circuit. Do not fuse ground­neutral.
See Chart C for receptacle voltage require­ments, proper fuse size, wire and wiring connections which must conform with rating of the appliance. Do not use an extension cord.
Chart-C
PLUG AND
RECEPTACLE
DATA
SERIAL PLATE
AMPERES
RECEPTACLE
MODEL WITH
SERIAL PLATE
OF 230 VOLTS
(207 MIN,253
MAX.)
I
MoDEL
SERIAL PLATE
OF 2301208
I
VOLTS
(197.6 MN
253 MAX,)
I
UP
through
16.0
USE TIME-DELAY
FUSE
OR TIME
DELAY CIRCUIT
BREAKER
RATING IN
AMPS
MINIMUM
RECEPTACLE
WIRE SIZE
TYPE
OF BRANCH
CIRCUIT
12 GAUGE
I
SINGLE
USE COPPER
OUTLET
WIRE ONLY
ONLY
RECEPTACLE WIRING
RECEPTACLE WIRING should be at least as large as size shown on electrical Chart C. Use copper wire only. It is the personal responsibility and obligation of the customer to provide proper and adequate receptacle wiring installed by aqualified electrician. OBSERVE NATIONAL ELECTRICAL CODE AND ALL LOCAL GOVERNING CODES AND ORDINANCES.
A three-wire, single-phase 60 hertz AC only electrical supply is required.
RECOMMENDED GROUNDING METHOD
Chart-D
For your personal safety, this appliance must be grounded. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the
cord must be plugged into a mating 3-prong
grounding type wall receptacle, grounded in accordance with the National Electrical Code and local codes and ordinances. If a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded 3-prong wall receptacle
installed by a qualified electrician.
ELECTRICAL
REQUIREMENTS
For 230 volt and 230/208 volt models with
serial plate amperes up through 24.0
Refer to Chart D for specific wiring and
receptacle information to be used.
OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES.
Do not, under any circumstances, remove the
power supply cord ground plug.
ELECTRICAL GROUND IS REQUIRED ON
THIS APPLIANCE.
A three-wire, single-phase 60 hertz AC only
electrical supply is required.
A separate electrical supply is required on a separately fused circuit. Do not fuse ground­neutral.
See Chart D for receptacle voltage require-
ments, proper fuse size, wire and wiring connections which must conform with rating of the appliance. Do not use an extension cord.
PLUG AND
RECEPTACLE
DATA
RECEPTACLE
VOLTAGE
(60 HERTZ
AC IN ALL
INSTANCES)
SERIAL PLATE
AMPERES
RECEPTACLE _
MODEL WITH
SERIAL PLATE
OF 230 VOLTS
(207 MIN,253
MAX.)
“P
through
1
MODEL WITH
24.0
SERIAL PLATE
OF 2301209
VOLTS
(197.6 MIN-
253 MAX.)
USE TIME-DELAY
FUSE
OR TIME
DELAY CIRCUIT
BREAKER
RATING IN
AMPS
MINIMUM
RECEPTACLE
WIRE SIZE
SEE BELOW
TYPE
OF BRANCH
CIRCUIT
CART.
TYPE
ONLY
10 GAUGE
USE COPPER
WIRE ONLY
SINGLE
OUTLET
ONLY
RECEPTACLE WIRING
RECEPTACLE WIRING should be at least as
large as size shown on electrical Chart D. Use copper wire only. It is the personal responsibility and obligation of the customer to provide proper and adequate receptacle wiring installed by a qualified electrician.OBSERVE NATIONAL
ELECTRICAL CODE A:\ID ALL LOCAL GOVERNING CODES AND ORDINANCES.
RECOMMENDED GROUNDING METHOD
For your personal safety, this appliance must be grounded. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong grounding type wall receptacle, grounded in accordance with the National Electrical Code and local codes and ordinances. If a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded 3-prong wall receptacle installed by a qualified electrician.
Loading...