S E R V I C E |
Whirlpool Europe |
Customer Services |
AWZ 465-SK
Service-Manual
Tumble Dryer
Air Vent
AWZ 465-SK
Model |
AWZ 465-SK |
|
Version |
8575 465 61000 |
Page |
|
Technical data |
2 |
|
Technical data |
3 |
|
Spare part list |
4 |
|
Exploded view |
5 |
|
Wiring diagram |
6 |
|
Circuit diagram |
7 |
|
Program diagram |
8 |
This documentation is only intended for qualified technicians who are aware of the respec-
tive safety regulations. |
|
Date: 02.08.1995 |
Subject to modification |
Document-No.: 4812 713 10359 |
|
02.08.1995 / Page 2 |
Whirlpool Europe |
|
S E R V I C E |
Doc. No: 4812 713 10359 |
Customer Service |
||
|
|
|
|
Technical data
Dimension |
|
|
Height |
85,0 |
cm |
Width |
59,5 |
cm |
Depth |
60,0 |
cm |
Wight |
|
|
With packing |
41 |
kg |
Without packing |
38 |
kg |
Power connection |
|
|
Voltage |
230 |
V |
Frequency |
50 |
Hz |
Connected load |
2,3 |
kW |
Fuse |
10 |
A |
Drum data |
|
|
Volume |
112 |
l |
Drum speed |
56 3 |
rpm |
Air flow |
|
|
Circulation air flow |
180-190 |
m3/h |
Cooling air flow |
180-185 |
m3/h |
Capacity of laundry |
|
|
programs |
amount of laundry |
|
Cotton |
5,0 |
kg |
Easy care |
2,5 |
kg |
Condenswater evacuation (alternative possible)
Condenswater container |
3,5 |
l |
Direct connection to the drainage |
|
|
1. Possibility: |
Use a commercially |
|
|
availablewater hose |
|
Inner diameter |
8 - 10 |
mm |
Max. allowable length |
2,5 |
m |
Maximum height for |
|
|
drain outlet |
1,0 |
m |
2. Possibility: |
Outlet hose for |
|
|
connect into siphon |
|
Spare part number |
4812 530 28243 |
|
Length of hose |
1,5 |
m |
Electrical components |
|
|
|
Heating |
|
heating register |
|
Rated voltage |
|
230 |
V |
Tolerance voltage |
|
+6 / -15 |
% |
Rated power consumption 20505% |
W |
||
Heating resistance’s |
|
Ω |
|
Connecting points 8 - 9 |
23,35% |
||
Mainand Blower motor |
|
|
|
Type |
1-phase asynchronous motor |
||
Voltage |
|
230 |
V |
Frequency |
|
50 |
Hz |
Power consumption |
2857% |
W |
|
Resistance's of coils |
|
Ω |
|
Main coil (2 -3) |
|
167% |
|
Auxiliary coil (2 - 1) |
|
167% |
Ω |
Rated speed |
|
|
|
With 5 kg laundry and |
|
|
|
100 % rest humidity |
277050 |
UPM |
|
Capacitor |
|
10 |
F |
Condensation pump |
|
|
|
Motor |
|
Synchronous motor |
|
Voltage |
|
220-240 |
V |
Frequency |
|
50 |
Hz |
Power consumption |
~ 142 |
W |
|
Capacity |
|
2,61,1 |
l/min |
Maximum height |
|
|
|
of pump outlet |
|
1,1 |
m |
Push-button switch |
|
|
|
Number of functions |
|
2 |
|
Start switch - SS |
|
Starts the appliance |
|
Gentle - PS 2 |
|
Temperature reduction |
|
Timer |
|
|
|
Number of steps |
|
60 |
|
Maximum drying time |
150 |
min |
|
Maximum heating time |
141 |
min |
|
Cooldown phase |
|
9 |
min |
Anticreasing phase |
|
15 |
min |
Drying time: |
|
|
|
Cotton 5,0 kg |
|
|
|
extra dry |
|
110 - 140 |
min |
cupboard dry |
|
80 - 130 |
min |
iron dry |
|
60 - 100 |
min |
Easy care 2,5 kg |
|
|
|
extra dry |
|
50 - 70 |
min |
cupboard dry |
|
40 - 60 |
min |
iron dry |
|
30 - 50 |
min |
S E R V I C E
Technical data
Whirlpool Europe |
02.08.1995 / Page 3 |
Customer Service |
Doc. No: 4812 713 10359 |
|
|
Thermostats |
|
|
|
Fluff thermostat (in Heater) TH. 1.2 |
|
|
|
Switching point |
123 |
2 |
˚C |
Safety thermostat (in Heater) TH. 1.4 |
|
|
|
Switching point |
150 |
5 |
˚C |
Safety thermostat (in air channel) TH. 1.1 |
|
|
|
Switching point |
85 |
3 |
˚C |
Thermostat (in Heater channel) TH. 1.5 |
|
|
|
Switching point |
125 |
5 |
˚C |
Reset |
manual |
|
All thermostats within the heater are separately not changeable!
Attention:
If the Thermostat TH. 1.5 (manually resetable) has switched off, the heater must be changed for safety reasons!