S E R V I C E |
Whirlpool Europe |
AWZ 121 |
Customer Services |
Service Manual
Tumble dryer
Air Vent
AWZ 121
Model |
AWZ 121 |
|
Version |
8575 121 10010 |
Page |
|
Technical data |
2 - 3 |
|
Spare part list |
4 |
|
Exploded view |
5 |
|
Wiring diagram |
6 |
|
Circuit diagram |
7 |
|
Program diagram |
8 |
This documentation is only intended for qualified technicians who are aware of the respec-
tive safety regulations. |
|
Date: 12.11.1998 |
Subject to modification |
Document-No.: 4812 713 11552 |
|
12.11.1998 / Page 2 |
AWZ 121 |
Whirlpool Europe |
|
S E R V I C E |
Doc. No: 4812 713 11552 |
8575 121 10010 |
Customer Service |
||
|
|
|
|
|
Technical data
Dimensions
Height |
85.0 |
cm |
Width |
59.5 |
cm |
Depth |
56.0 |
cm |
Weight |
|
|
Gross weight |
33 |
kg |
Net weight |
31 |
kg |
Surroundings temperature |
|
|
Max.room temperature |
35 |
˚C |
Min. room temperature |
5 |
˚C |
Humidity |
|
|
Max. relative humidity |
95 |
% |
Power connection |
|
|
Voltage |
230 |
V |
Frequency |
50 |
Hz |
Connected load |
2.8 |
kW |
Fuse |
16 |
A |
Drum data |
|
|
Volume |
104 |
l |
Drum speed (empty) |
56 ± 3 |
rpm |
Airflow |
120 - 160 |
m3 /h |
Maximum loading capacity |
|
|
Cotton |
5 |
kg |
Easy care |
2.5 |
kg |
Exhaust hose |
|
|
Inner diameter |
10 |
cm |
Maximum allowable |
4 |
m |
(with 2 bows) |
|
|
Electrical components |
|
|
Heating |
|
|
Type |
Aluminium mass |
|
|
heating |
|
Nominal voltage |
230 |
V +6%/-15% |
Nominal power |
2500 |
W ± 5% |
Resistor R 20 |
19.5 - 23 |
Ω |
Thermostats
Safety thermostat (in heater) TL
Switching point off |
270± 10 ˚C |
Fluff thermostat (in heater) TH 1.2 |
|
Switching point on |
195 ± 7.5 ˚C |
Switching point off |
220 ± 7.5 ˚C |
Exhausting thermostat (in bottom) TH 1.1
Switching point on |
45 ± |
5 |
˚C |
Switching point off |
60 ± |
4 |
˚C |
Caution:
If one of the thermostats is defective, the whole heating element has to be changed for safety reason !
Therefore, the thermostats are not available as separate spare parts !
Timer |
|
|
Type |
Electromechanical |
|
|
Timer, Eaton |
|
|
EC 4605 |
|
Nominal voltage |
230 |
V |
Frequency |
50 |
Hz |
Number of steps |
60 |
|
Stop |
01 |
|
Heating |
02 - 53 |
(138 min.) |
Cool down |
54 - 55 |
(6 min.) |
Anticreasing |
56 - 59 |
(12 min.) |
Stop |
60 |
|
Ambient temperature |
up to 70 |
˚C |
Storage temperature |
up to 85 |
˚C |
Mainand blower motor |
|
|
Type |
1-phase asynchronous |
|
Nominal voltage |
230 |
V |
Frequency |
50 |
Hz |
Power consumption |
295 |
W ± 7% |
Resistances of coils |
|
|
Main coil (2-3) |
24.7 |
Ω ± 7% |
Auxiliary coil (2-1) |
25.6 |
Ω ± 7% |
Rated speed with 5 kg laundry |
|
|
and 100 % rest humidity |
2730 |
rpm |
Capacitor |
10 μF ± 10% / 400V |
S E R V I C E
Technical data
Whirlpool Europe |
AWZ 121 |
12.11.1998 / Page 3 |
Customer Service |
8575 121 10010 |
Doc. No: 4812 713 11552 |
|
|
|
Push buttons |
|
|
Gentle switch |
SG |
|
Nominal voltage |
230 V |
|
Nominal current |
16 |
A |
Start / door switch |
|
|
Start switch |
SST |
|
Nominal voltage |
230 |
V |
Nominal current |
16 |
A |
Door switch |
SD |
|
Nominal voltage |
230 |
V |
Nominal current |
16 |
A |
Radio interference filter |
|
|
Type |
ISKRA KPB 7325 |
|
Nominal voltage |
max. 275 V |
|
Nominal capacity |
0.1 μF X1+ 2 x 0.022 μF Y2 + 1MΩ |
|
Buzzer |
|
|
Nominal voltage |
230 |
V |
Resistance of coil |
7 |