Whirlpool ARC 5580 Service Manual

SERVICE
Model ARC 5580 Version 8501 558 10005 Page
Whirlpool Europe Customer Services
ARC 5580
Service Manual
Freestanding Cooling Combi ARC 5580
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respec­tive safety regulations. Date: 29.03.2004 (Mod. 01) Subject to modification Document-No.: 4812 731 18815
28.01.2004 / Page 2 ARC 5580 Whirlpool Europe Doc. No: 4812 731 18815 8501 558 10005 Customer Service
Technical data
SERVICE
Factory Code CB 392 W
Dimensions
Height 203.2 cm Width 60.0 cm Depth 62.1 cm
Capacity
Total
gross 350 l net 332 l
Cooling
gross 242 l net 240 l
Freezing
gross 108 l net 92 l
Electrical connection
Voltage 220 - 240 V Frequency 50 Hz
Power consumption
in 24 hours 0.97 kWh
Freezing capacity
Compressor (cooling)
Type TLES 5 KK2 Capacity (CECOMAF) 57 W
Compressor (freezing)
Type HLY 90 AA Capacity (CECOMAF) 109 W
Refrigerant (cooling)
Type R 600 a Quantity 23 g
Refrigerant (freezing)
Type R 600 a Quantity 37 g
Thermostat switching value (cooling)
Switch on temperature min. + 3.5 ˚C Switch on temperature max. + 3.5 ˚C Switch off temperature min. - 8.0 ˚C Switch off temperature max. - 26.0 ˚C
in 24 hours 10 kg
Thermostat switching value (freezing)
Switch on temperature min. - 14.5 ˚C Switch on temperature max. - 21.5 ˚C Switch off temperature min. - 25.0 ˚C Switch off temperature max. - 32.0 ˚C