SERVICE
Model ARC 5570
Version 8501 557 10005 Page
Whirlpool Europe
Customer Services
ARC 5570
Service Manual
Freestanding Cooling
Combi
ARC 5570
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 20.01.2004 Subject to modification
Document-No.: 4812 731 18724
20.01.2004 / Page 2 ARC 5570 Whirlpool Europe
Doc. No: 4812 731 18724 8501 557 10005 Customer Service
Technical data
Factory Code CB 391 W
Dimensions
Height 203.2 cm
Width 60.0 cm
Depth 62.1 cm
Capacity
Total
gross 350 l
net 332 l
Cooling
gross 242 l
net 240 l
Freezing
gross 108 l
net 92 l
SERVICE
Electrical connection
Voltage 220 - 240 V
Frequency 50 Hz
Power consumption
in 24 hours 0.97 kWh
Freezing capacity
in 24 hours 4.5 kg
Compressor
Type HQM 11 AA
Capacity (CECOMAF) 127 W
Refrigerant
Type R 600 a
Quantity 57 g
Thermostat switching value
Switch on temperature min. + 4.5 ˚C
Switch on temperature max. + 4.5 ˚C
Switch off temperature min. - 19.0 ˚C
Switch off temperature max. - 33.0 ˚C