Whirlpool APGH1/IX INSTRUCTION FOR USE

APGH1 PRODUCT DESCRIPTION SHEET

GB IE

Operation of burners with electric ignition

To light one of the burners:

Press the relative knob and turn it anticlockwise to the large flame setting .

At the same time, keep the push-button with a star .

The spark plug gives out a spark that causes the burner to ignite.

If the burner does not ignite, press the pushbutton again.

1.Removable panstand grids

2-3. Medium burners

4.Large burner

5.Small burner

6. Medium burner control knob

7. Medium burner control knob

8. Large burner control knob

9. Small burner control knob

10. Electric ignition button

Symbols

Shaded circle

Tap closed

Large flame

Maximum opening/

delivery

 

Small flame

Minimum opening

or reduced delivery

 

Note:

Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the

operation with the knob turned to the small flame setting .

5019 619 61241

Whirlpool APGH1/IX INSTRUCTION FOR USE

DIMENSIONS OF COOKING HOB AND WORKTOP

NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.

INJECTORS TABLE

 

 

 

 

 

 

 

 

CATEGORY II2H3+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas

 

 

Type of

Injector

Rated

 

Rated

 

Reduced

 

Gas pressure

used

 

 

burner

marking

heat

 

consumption

 

heat

 

 

 

 

 

 

 

 

 

 

 

 

capacity

 

 

 

 

 

capacity

min.

 

rat.

 

max.

 

 

 

 

 

 

Pcs-kW

 

 

 

 

 

Pcs-kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

 

large

128

 

3.00

 

 

286 l/h

 

0.60

 

 

 

 

 

 

 

medium

94

 

1.65

 

 

157 l/h

 

0.35

17

 

20

 

25

(Methane)

G 20

 

 

 

 

 

 

 

 

small

76

 

1.00

 

 

95 l/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

 

large

85

 

3.00

 

 

218 l/h

 

0.60

 

 

 

 

 

 

 

medium

65

 

1.65

 

 

120 l/h

 

0.35

20

 

28-30

 

35

(Cylinder)

G 30

 

 

 

 

 

 

 

 

small

50

 

1.00

 

 

73 l/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

 

large

85

 

3.00

 

 

214 l/h

 

0.60

 

 

 

 

 

 

 

medium

65

 

1.65

 

 

118 l/h

 

0.35

25

 

37

 

45

(Cylinder)

G 31

 

 

 

 

 

 

 

 

small

50

 

1.00

 

 

71 l/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas

 

Appliance

 

Total rated

 

 

Total rated

 

Air required

 

used

 

 

model

 

 

heat capacity

 

consumption

 

for burning

 

 

 

 

 

 

 

Pcs-kW

 

 

 

 

 

 

m3/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 20 20 mbar

 

4 gas

 

 

7.30

 

 

 

695 l/h

 

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 30 28-30 mbar

 

4 gas

 

 

7.30

 

 

 

531 g/h

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 31 37 mbar

 

4 gas

 

 

7.30

 

 

 

521 g/h

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loading...