AKM 370/01 PRODUCT DESCRIPTION SHEET
RU PL HU SK CZ BU RO
1. Removable panstand grids
2-5. Medium burners
3. Large burner
4. Small burner
6. Double crown burner
7. Small burner control knob
8. Large burner control knob
9. Double crown burner control knob
10. Medium burner control knob
11. Medium burner control knob
Symbols
Operation of burners with safety device
and electric ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame and star
setting .
• At the same time, keep the knob pressed
against the control panel until the burner
ignites.
• After the burner has ignited, keep the knob
pressed for about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note:
— Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
Shaded
circle
Large
flame
and star
Small
flame
— The safety device of the burner shuts off the
gas supply to the burner if its flame goes out
accidentally (because of a sudden gust of
wind, an interruption in the gas delivery, the
overflowing of liquids, etc.).
— The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
Tap closed
Maximum opening/delivery
and electric ignition
Minimum opening
or reduced delivery
USING THE DOUBLE-RING BURNER
When using the double-ring burner, leave the knob
on the maximum setting (large flame ) for at
least five minutes after lighting before selecting a
lower setting.
5019 319 61731
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 680 mm, the
height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the
cooktop, the height “B” must be a minimum of 400 mm.
Before installing a hood above the cooktop please refer to the hood instructions,
which specify the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of
gas used
NATURAL GAS
(Methane) G 20
LIQUID
PETROLEUM GAS
(Cylinder) G 30
LIQUID
PETROLEUM GAS
(Cylinder) G 31
Type of
gas used
Type of
burner
double crown
large
medium
small
double crown
large
medium
small
double crown
large
medium
small
Appliance
model
139
128
94
76
92
85
65
50
92
85
65
50
Rated heat
capacity
Pcs-kW
3.30
3.00
1.65
1.00
3.30
3.00
1.65
1.00
3.30
3.00
1.65
1.00
Injector
marking
Total rated heat
capacity
Pcs-kW
Rated
consumption
314 l/h
286 l/h
157 l/h
95 l/h
240 g/h
218 g/h
120 g/h
73 g/h
236 g/h
214 g/h
118 g/h
71 g/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
1.50
0.60
0.35
0.30
1.50
0.60
0.35
0.30
1.50
0.60
0.35
0.30
G 20 20 mbar 5 gas 10.6 1009 l/h 21.2
G 30 28-30 mbar 5 gas 10.6 771 g/h 21.2
G 31 37 mbar 5 gas 10.6 757 g/h 21.2
Gas pressure
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for
burning
3
m
/h