AKM 350/01 PRODUCT DESCRIPTION SHEET
NL
1. Removable panstand grids
2. Large burner 3-4. Medium burners
5. Small burner
6. Medium burner control knob
7. Large burner control knob
8. Medium burner control knob
9. Small burner control knob
Symbols
Shaded circle Tap closed Large flame
and star
Small flame
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-clockwise to the large flame and star setting .
Release the knob.
If the burner does not ignite, repeat the operation described above.
5019 319 61521
Note — Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance “A“ between the wall cabinets is between 600 mm and 680 mm,
the height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is greater than the width of the Cooktop, the height “B” must be a minimum of 400 mm. In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY I2L
Type of gas used
NATURAL GAS (Methane) G 25
Type of gas used
G 25 25 mbar
Type of burner
large medium small
Appliance model
4 gas 7.80 863 l/h 15.6
Injector marking
129 108
78
Rated heat capacity Pcs-kW
3.00
1.90
1.00
Total rated heat capacity Pcs-kW
Rated consumption
332 l/h 210 l/h 111 l/h
Reduced heat capacity Pcs-kW
0.60
0.35
0.35
Total rated consumption
Gas pressure
min. rat. max.
20 25 30
Air required for burning
3
m
/h