AKL 704 PRODUCT DESCRIPTION SHEET
NL
1. Removable panstand grids
2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
Symbols
Shaded circle Tap closed
Large flame
Small flame
Maximum opening/
delivery
Minimum opening or
reduced delivery
Operation of burners
with electric ignition
To light one of the burners:
• Press the relative knob and turn it anti-clockwise
to the large flame setting .
• At the same time, approach a flame to the
relative burner until it ignites.
If the burner does not ignite, repeat the operation.
5019 519 01009
DIMENSIONS OF COOKING HOB AND
WORKTOP (mm)
NOTES: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY I2L
Type of gas
used
NATURAL GAS
(Methane) G 25
Type of gas
used
G 25 25 mbar 4 gas 7.30 809 l/h 14.6
Ty p e o f
burner
large
medium
small
Appliance
model
Injector
marking
F3 126
T8 96
F1 72
Rated heat
capacity
kW
3.00
1.65
1.00
Total rated
heat capacity
kW
Rated consumption
332 l/h
183 l/h
111 l/h
To t a l rate d
consumption
Reduced
heat
capacity
kW
0.60
0.35
0.35
ELECTRIC SUPPLY: 230V - 50Hz
Gas pressure mbar
min. rat. max.
20 25 30
Air required
for burning
3
m
/h