Whirlpool AKF 616 IX, AKF 619 IX, AKF 615 IX, AKF 618 IX INSTRUCTION FOR USE

Whirlpool AKF 616 IX, AKF 619 IX, AKF 615 IX, AKF 618 IX INSTRUCTION FOR USE

AKF 618 / AKF 619 PRODUCT DESCRIPTION SHEET

IT

1. Removable grids

2-5. Medium burners

3. Large burner

4. Auxiliary burner

6. Triple crown burner

7. Front left burner control knob

8. Rear left burner control knob

9. Central burner control knob

10. Rear right burner control knob

11. Front right burner control knob

Symbols

Shaded

Tap closed

circle

 

Large flame

Maximumopening/delivery

and star

and electric ignition

Small flame

Minimum opening or

reduced delivery

 

Operation of burners with safety device and electric ignition

To light one o the burners:

Press the relative knob and turn it anti-

clockwise to the large flame and star setting .

At the same time, hold the knob down until the burner ignites.

After the burner has ignited, keep the knob pressed for about 10 seconds.

Release the knob.

If the burner does not ignite, repeat the operation.

Note:

Should particular local conditions of the delivered gas make ignition of the burner difficult, it is advisable to repeat the operation

with the knob turned to the small flame setting .

The burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of a sudden draught, an interruption in the gas delivery, boiling over of liquids, etc.).

The separator panel, positioned beneath the cooktop at a minimum distance of 20 mm, must be sealed.

Insert a wooden panel at least 20 mm thick under the hob, at a distance of at least 15 mm from the cooking hob bottom.

5019 519 66008

DIMENSIONS OF COOKING HOB AND WORKTOP (mm)

NOTES: If the distance “A” between the wall cabinets is between 600 mm and 680 mm, the height “B” must be at least 520 mm.

If the distance “A” between the wall cabinets is greater than the width of the hob, the height “B” must be a minimum of 400 mm.

Before installing a hood above the hob please refer to the hood instructions, which specify the correct distance.

INJECTORS TABLE

 

 

 

 

 

 

 

CATEGORY II2H3+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas used

Type of

Injector

 

Rated heat

Rated

Reduced

 

 

Gas pressure mbar

 

 

burner

marking

 

capacity

consumption

heat

 

 

 

 

 

 

 

 

 

 

100/mm

 

kW

 

 

 

capacity

 

min.

rat.

 

max.

 

 

 

 

 

 

 

 

 

 

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

triple crown

141

 

3.50

 

333 l/h

1.50

 

 

 

 

 

 

rapid

129

 

3.00

 

286 l/h

0.80

 

17

20

 

25

(Methane)

G20

semi-rapid

101

 

1.75

 

167 l/h

0.50

 

 

 

 

 

 

 

 

 

 

 

 

auxiliary

77

 

1.00

 

95 l/h

0.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID

 

triple crown

94

 

3.50

 

254 g/h

1.50

 

 

 

 

 

 

 

rapid

87

 

3.00

 

218 g/h

0.80

 

 

 

 

 

 

PETROLEUM GAS

 

 

 

20

28-30

 

35

semi-rapid

66

 

1.75

 

127 g/h

0.50

 

 

(Cylinder)

G30

 

 

 

 

 

 

 

 

auxiliary

50

 

1.00

 

73 g/h

0.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID

 

triple crown

94

 

3.50

 

254 g/h

1.50

 

 

 

 

 

 

 

rapid

87

 

3.00

 

218 g/h

0.80

 

 

 

 

 

 

PETROLEUM GAS

 

 

 

25

37

 

45

semi-rapid

66

 

1.75

 

127 g/h

0.50

 

 

(Cylinder)

G31

 

 

 

 

 

 

 

 

auxiliary

50

 

1.00

 

73 g/h

0.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas

 

 

Appliance model

Total rated heat

 

Total rated

 

 

Air necessary (m3)

used

 

 

 

 

capacity

 

consumption

 

 

for the combustion

 

 

 

 

 

kW

 

 

 

 

 

of 1 m3 of gas

 

G20 20 mbar

 

 

5 gas

 

11

 

 

1048

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G30 28-30 mbar

 

5 gas

 

11

 

 

799

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G31 37 mbar

 

 

5 gas

 

11

 

 

799

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC SUPPLY: 230 V ~ 50 Hz