Whirlpool AD65USM0, AD65USL1, AD65LEK0, AD60LBK0, AD50USL4 Owner’s Manual

...
Dehumidifier
Use&CareGuide
q
Contents
Safetyinformation..................................
ElectTicalrequirements............................... .3
Installingdehumidifier............................... .4
Operatingdehumidifier............................. .5-6
Removingandemptyingwaterbucket..................... 7
Waterlevelfloatandautomaticshutoff................... .8
Ifyouneedassistanceorservice...................... 10-11
Part No. 1185020 Rev.A
Your safety and the safety of others
are very important•
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
l_ his is the safety alert symbol.This symbol alerts you to potential hazards that can kilt or hurt you
and others.
Atl safety messages will follow the safety alert symbol and either the word "DANGER" or '"WARNING." These words mean:
You can be killed or seriously injured if you don't immediately follow
instructions.
You can be killed or seriously injured if you don't follow instructions.
Atl safety messages will tell you what the potential hazard is, tell you how to
reduce the chance of injury, and tell you what can happen if the instructions
are not followed.
IMPORTANT SAFETY INSTRUCTIONS
WARNING --To reduce the risk of fire, electrical shock, injury or
sickness when using your dehumidifier, follow these basic precautions:
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
-- SAVE THESE INSTRUCTIONS --
It is your responsibility to:
Install the dehumidifier according to the Installation Instructions.
Connect the dehumidifier only to the proper kind of outlet, with the correct electrical supply and ground. See "Electrical requirements;' page 3.
Unplug dehumidifier before servicing.
Do not drink water collected in the
water bucket.
Electrical Shock Hazard
Plug into a grounded 3 prong
outlet.
Do not remove ground prong. Do not use an adapter.
Do not use an extension cord. Failure to follow these
instructions can result in death,
fire, or electrical shock.
Groundinginstruclions:
3,,_ongground-type
o_tlet ".,.,........
3-pr0ng
groundplug
........__d _I I_\/_,,,j_/'_e_;'°li _\/
%
powersupplycord
For your personal safety, this
dehumidifier must be grounded.This dehumidifier is equipped with a power
supply cord having a 3-prong ground plug.
A 115-volt (103.5 min., 126.5 max.), 60-Hz, AC-only, 15- or 20-ampere fused
and properly grounded electrical supply is required. A time-delay fuse or
time-delay circuit breaker is
recommended. Use a separate circuit to connect only the dehumidifier.
To minimize possible shock hazard, the cord must be plugged into a mating
3-prong ground-type outlet, grounded in accordance with local codes and
ordinances. If a mating outlet is not available, it is the personal
responsibility and obligation of the
customer to have the properly grounded outlet installed by a qualified
electrician.
Good air circulation is needed for best performance--allow
at least 12-18 inches (30.5 -
45.7 cm) of air space on all sides of the dehumidifier.
]2.-18"_
(30.5-4-5.7cm)
Keep all outside doors, windows and other
openings closed when operating dehumidifier.
Humid outdoor air will increase dehumidifier workload.
Install dehumidifier on a level floor strong enough to support the dehumidifier with a full bucket of water.
(30.5-45.7cm)
Note: Before turning dehumidifier on,
be sure that:
Dehumidifier is plugged into the wall outlet
Bucket is properly inserted into dehumidifier
Bucket is empty
ControlA
/ J _//_-,_-_"" _'_.-.---_lNtsI_idityrmoovalset
ControlB / E_H I /C_) _ \ palnt(..o_t_moist_o
I 9 ) fromremo)
selectsfanspeed
indicatesthebudletisfull
..."OR
.."" thebudletisnotinposiUon
adjustshumidityremovalset point(amouatofmoisture
removedfromroom)
indicatestheburlierisfull
........ OR
TOTURNDEHUMIDIFIERON:
Turn DRYNESSCONTROL clockwise.
FANSPEED:
(Models with Control B only): This controls fan operation. Use desired setting. HIGH - for faster moisture removal.
LOW - for slower moisture removal.
DRYNESSCONTROL:
This controls the amount of moisture in
the room.Turn control knob clockwise for more drying.Turn control knob
counterclockwise for less drying.Turn control knob to "NORMAL"to maintain
average humidity conditions.
NOTE: For the first few days of use, turn
the DRYNESS CONTROL clockwise to
"DRYEST"to remove extra moisture from
the furnishings as well as the room air.
EMPTY/ADJUSTBUCKETlight:
Ifthis light is on, the dehumidifier is not running. This light indicates that you
need to check:
If the bucket is full, empty bucket and replace.
If the bucket is not in position, remove bucket and replace. Make
sure the bucket fits all the way into the dehumidifier and the light is off,
or dehumidifier will not run.
TOTURNDEHUMIDIFIEROFF:
Turn DRYNESSCONTROL counterclockwise to OFF.
ControlC
.. _ates _ebucketis
OR
_ebucketisnotinpo_,3tion
J
selectsmode
TOTURNDEHUMIDIFIERON:
Pressthe ON/OFFbutton. All lightswill flash once. If the Empty/Adjust Bucket light comes on, the dehumidifier will not
operate. Empty or adjust bucket.
Each time you unplug the dehumidifier or power is interrupted, the control will return to your previous settings.
MODESELECTION
Press MODE button to select fan speed. Choose LOW,HIGH, CONTINUOUS or
AUTO DRY.
If you have selected LOW or HIGH:
Press 4 or I, to set the amount of moisture you want removed. Pressing !_
increases the amount of moisture removed; pressing 4 decreases the
amount of moisture removed.The indicator light will change according to
the number of times you press 4 or I,.
If you have selected CONTINUOUS:
You cannot change the amount of moisture you want removed.
"" adjustshumidityremovalsetpoint
(_nour_ofmois_eremovedfTomroom)
Pressing 4 or !_will not increase or
decrease the amount of moisture
removed. If you have selected AUTO DRY:
Press 4 or I, to set the amount of moisture you want removed. The
dehumidifier will automatically adjust fan speed andlor turn on and offto
maintain your setting.
TOTURNDEHUMIDIFIEROFF:
Pressthe ON/OFF button.The
dehumidifier will retain your last
settings.
EMPTY/ADJUSTBUCKETlight
Ifthis light is on, the dehumidifier is not running. This light indicates that you
need to check
If the bucket is full, empty bucket and replace.
If the bucket is not in position, remove bucket and replace. Make sure the bucket fits all the way into the dehumidifier and the light is off,
or dehumidifier will not run.
Sickness Hazard
Do not drink water collected in
water bucket.
Doing so can result in sickness.
1. Useboth side handles to lift bucket.
Pull bucket forward and remove.
2.Carry bucket to a large sink or tub.
Drainhoseconneclionmethod:
(to drainwaterfrombucketcontinuously)
1. If your dehumidifier does not have a drain hose connector cover, go to
Step 2.
If your dehumidifier has a drain hose connector cover, use a flat-
blade screwdriver to remove cover from drain connector.Turn cover counterclockwise. Discard cover. It
cannot be reused. Go to Step 2.
"" damage
DO NOt
outside or connection
will leak.
center of drain hose connector
2. Drill out only the center of the drain hose connector. Use a minimum I/4"
drill bit.
/
3. Pour water through opening into a sinkor tub.
4. Replace bucket completely and check that EMPTY/ADJUST BUCKET
light is off.
3. Attach a garden hose to drain hose connector.The garden hose should not be longer than 8 feet (2.4 m). Run other end of garden hose into a floor
drain. Check that the hose lies fiat and in the drain.
Tousethebucketwithoutthegardenhose:
Use a garden hose cap to seal the drain hose connector.
Alldehumidifiershaveautomatic shutoffandawaterlevelfloat.Some
dehumidifiersfeatureanadjustable WaterLevelFloat.Thebucketmustbe
Formodelswithadjustable
WaterLevelFloat:
properlyalignedfortheWaterLevel Floattowork.
Formodelswithnon-adjustable
WaterLevelFloat
You can set the adjustable Water Level
Float at the "high" or "low" position. Both settings will turn off the dehumidifier
automatically.
The Water Level Float will shut offthe
dehumidifier automatically.
"High" setting: Water Level Float is
preset to the "high" position--left side of opening.The dehumidifier will shut off automatically when bucket is 3/4
full.
"Low" setting: Slide Water Level Float to
"low" position--right side of opening
-- to make the bucket lighter to carry. The dehumidifier will shut off
automatically when bucket is I/2 full.
Loading...