Westinghouse P5RF Technical Literature

TECHNICAL SPECIFICATIONS
P5RF Series Rev "A"
Single Packaged Air Conditioner Single Phase
15 SEER, 12 EER, R-410A 2 thru 5 Ton Units
Cooling: 24,000 to 57,500 Btuh
The P5 Series single packaged air conditioners are high efficiency self contained cooling and heating units that can be installed on a slab. Units are ETL and ETLc listed.
FEATURES and BENEFITS
• State-of-the-art Copeland Ultra-Tech II Scroll compressor: Provides two stage heat/cool.
• R-410A Refrigerant: Environmentally friendly.
• Designed using galvanized steel: With a polyester
urethane coat finish. The 950 hour salt spray finish resists corrosion 50% better than comparable units.
• Both indoor and outdoor coils: Are designed to optimize heat transfer, minimize size and cost, and increase durability and reliability.
• The service valves are easily accessible: And simplify servicing of the refrigeration system.
• Wire guard coated with Earth Friendly Epoxy and mesh hail guard that will never rust: Protects the coil
from being damaged by balls, lawnmowers, hail, etc.
• Designed to make servicing easier: For the contractor, access panels are provided to all major components.
• 0" clearance: To combustibles on duct side of the unit allows for installations in tight areas.
• Easy access: To evaporator for cleaning and general maintenance.
• Drain trap: Design optimizes drain-age capabilities.
• Easy to install: Electric heat strip provides up to 20 kw
of heat output.
• Compact footprint and profile: Make the P5 Series easy to install and transport.
• High and Low Pressure Switches: Added compressor protection.
• Compressor sound blanket: Is standard.
• Energy efficient: Brushless DC (ECM) blower motor.
• Quiet operation and low vibration swept-wing for
blade combined with custome V enturi condenser fan.
• Protected distributor tubes Both indoor and outdoor coils include very high abrasive resistant fiberglass sleeves to prevent leaks from the tubing rubbing together.
L
W
MODEL IDENTIFICATION CODE
P 5 R F - X 24 K A
Application
P = Air Conditioning Packaged Unit
Generation 1, 5, Etc.
Round Duct
DIMENSIONS
D = 13 SEER F = 15 SEER
Nominal Capacity
x 1000 Btu
X = TXV
Revision
Electrical Code
K = 208/230-60-1
Top View
Model No.
P5RF-
X24KA 49 35 30.2 35.02 2.48 X36KA 49 35 30.2 35.02 2.48 X48KA 49 35 38.2 35.02 2.48 X60KA 63 35 38.2 35.02 2.48
(L) (W) (H)
Length Width Height A B
Model No.
P5RF-
Return
Diameter (in)
Supply
Diameter (in)
X24KA 14 12 X36KA 14 12 X48KA 14 12 X60KA 14 12
2
18.01
Electric Heater Power Supply Power Supply
Low Voltage Supply
Control Access
Panel
Blower Access Panel
H
17.86
15.36
10.10
3/4" NPT Drain Connection
1"
12.13
1.38
3.2
3.2 5.29
DIMENSIONS Continued
9.15
9.04
17.50
14" diameter Return Duct Opening
12" diameter Supply Duct Opening
3.0
5.5
1"
3.15
A
B
Side View
Back (Duct) View
3
Loading...