Westermo MX-69 User Manual

Page 1
2 x 4-kanalers fiberoptisk multiplexer
för rackmontering
2 x 4-channel fibre optic multiplexer
for rack mounting
2 x 4-Kanal Glasfaser Multiplexer
für Rackmontage
INSTALLATIONSANVISNING
INSTALLATIONS ANLEITUNG
6119-2001
www.westermo.se
MX-69 ST
©
Westermo Teleindustri AB • 1999 • REV.A
Galvanic
Isolation
CE
Approved
Page 2
4 6119-2001
Connection
Specifications MX-69
Transmission Asynchronous/synchronous full/half duplex or simplex
Interface 1 EIA RS-232-C/CCITT V.24 25 pole D-sub connector female
Interface 2 820nm fibre optic cable with ST connectors.
(See table of power budget)
Isolation 1000V
Power supply 15–25V DC
Power consumption 15V/200mA, 25V/120mA (PS-02) 3VA
Data rate Up to 38 400 bit/s arbitrary and independent
for each channel
Temp. range 5–50°C ambient temperature 0–95% RH
without condensation
Mounting In rack RV-01, occupies one slot
Mounting
The MX-69 is designed for mounting in Westermo’s rack RV-01 and is powered by the power supply PS-02. Other Westermo products can be mounted in the same rack provided that less than maximum of MX-69 are mounted. In case more than 6 pcs MX-69 are used in one rack two PS-02 are needed.
A maximum of 12 pcs MX-69 can be mounted in one RV-01.
The eight channels can be used to transmit any signal in the RS-232 interface.
Interface 2
Connection channel 1–4
Rx
Tx
Rx
Tx
Power supply
Connection channel 5–8
Page 3
56119-2001
Tx
Rx
Interface 1
The signal ground (SG) is connected to pin: 4, 7, 10, 13, 14, 17, 20, 23
Channel 1–4
Rx
Tx
Channel 5–8
Channel 1–4
Channel 5–8
Rx
Tx
Tx
Rx
MX-69 2 x MX-61
Line connection
Direction Pin Description
In 2 TxD channel 1 Out 15 RxD channel 1 In 3 TxD channel 2 Out 16 RxD channel 2 In 5 TxD channel 3 Out 18 RxD channel 3 In 6 TxD channel 4 Out 19 RxD channel 4 In 8 TxD channel 5 Out 21 RxD channel 5 In 9 TxD channel 6 Out 22 RxD channel 6 In 11 TxD channel 7 Out 24 RxD channel 7 In 12 TxD channel 8 Out 25 RxD channel 8
Power budget
Fibre (820nm) Power budget
50/125 mm 3.7 dB 62,5/125 mm 7.5 dB 200 mm PCS 18 dB
Attenuation in fibre cable
The values below can differ depending on quality and manufacturer of the fibre-optic cable.
Typical attenuation in connectors
0.2–0.4 dB
Typical attenuation in splice
Svetsad 0.1 dB Mekanisk 0.2 dB
Fibre Attenuation at 820nm
50/125 µm 3.0 dB/km
62.5/125 µm 3.5 dB/km
Page 4
8 6119-2001
Hints
Some hints on set-up of the MX-69.
1. Check the cable between your RS-232 interface and the RS-232 on the MX-69. The RS-232 interface on the MX-69 is configured as DCE (Data Communication Equipment). See suggestions on page 9 of cable configuration to connect eight RS-232 equipments to a MX-69.
How to check whether the equipment is DTE or DCE:
Power up the unknown equipment and ensure that nothing is plugged into the RS-232
interface. Using a multi-meter, first measure the voltage on pin 2 of the connector (male or female) with reference to ground on pin 7 (25 pole connector) or on pin 5 (9 pole connector, PC standard). Then measure the voltage on pin 3 in the same way. The pin with the most negative voltage will be output pin and will identify the device as DCE or DTE.
25 pole connector RS-232-C
If the most negative voltage is on pin 2: the device is DTE.
If the most negative voltage is on pin 3: the device is DCE.
9 pole connector, PC standard
If the most negative voltage is on pin 3: the device is DTE.
If the most negative voltage is on pin 2: the device is DCE.
Page 5
96119-2001
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
DTE
25-pos.
DTE
9-pos.
DCE 25-pos.
MUX 1 Channel 1
MUX 1 Channel 3
MUX 1 Channel 4
MUX 2 Channel 1
MUX 2 Channel 2
MUX 2 Channel 3
MUX 2 Channel 4
MUX 1 Channel 1
MUX 1 Channel 2
MUX 1 Channel 3
MUX 1 Channel 4
MUX 2 Channel 1
MUX 2 Channel 2
MUX 2 Channel 3
MUX 2 Channel 4
DCE 25-pos.
3
5
2
3
5
2
3
5
2
3
5
2
3
5
2
3
5
2
3
5
2
3
5
2
2
7
3
2
7
3
2
7
3
2
7
3
2
7
3
2
7
3
2
7
3
2
7
3
MUX 1 Channel 2
Page 6
Block diagram
2 3 5 6
15 16 18 19
8
9 11 12
21 22 24 25
4
7 10 13 14 17 20 23
DCE Socket
DEMUX 1
Channel 1-4
MUX 1
Channel 1-4
SG
RX
TX
DEMUX 2
Channel 5-8
MUX 2
Channel 5-8
RX
TX
6119-2001 01.99 TunaTryck AB, Eskilstuna, Sweden
Westermo Teleindustri AB • S-640 40 Stora Sundby, Sweden
Phone +46 16 612 00 Fax +46 16 611 80
E-mail: info@westermo.se • Westermo Web site: www.westermo.se
Westermo Teleindustri AB have distributors in several countries,
contact us for further information.
Westermo Data Communications GmbH Bruchsaler Straße 18, 68753 Waghäusel Tel.: +49(0)7254-95400-0 • Fax.:+49(0)7254-95400-9 E-Mail: westermo.germany@t-online.de
Westermo Data Communications Ltd Solent Business Centre • Millbrook Road West Millbrook, Southampton • SO15 0HW Phone: +44(0)1703-704 611 • Fax.:+44(0)1703 702 682 E-Mail: sales@westermo.co.uk
Subsidiaries
Loading...