Korthållsmodem
Short Haul Modem
Kurzstreckenmodem
INSTALLATIONSANVISNING
INSTALLATION MANUAL
INSTALLATIONS ANLEITUNG
6019-2001
www.westermo.se
MA-19
©
Westermo Teleindustri AB • 1998 • REV. A
Galvanic
Isolation
Transient
Protection
Balanced
TransmissionCEApproved
8 6019-2001
Specifications
Transmission Asynchronous Full/half duplex or simplex
Interface 1 EIA RS-232-C/CCITTV.24, V.28
25-pin D-sub, female DCE
Interface 2 10 mA tri-state balanced current loop 5-position
detachable screw-terminal mounted on the
rack’s back board
Transmission rate 0-38,4 kbit/s
Indicators Power, TD, RD, RTS, DCD
Isolation Complete galvanic insulation with opto-coupler (data)
and transformer (supply)
Isolation voltage 1500 V
Power supply External through PS-02 mounted in rack (RV-01)
±20 V DC ±20%
Power consumption +20V 60 mA, -20V 40 mA
Temperature range 5-50°C
Humidity 0-95% RH, non-condensing
Dimension 100x100 mm
Weight 0.1 kg
Mounting In rack, takes one card-slot in RV-01
96019-2001
F2
F1
S1
Switch settings
The MA-19 can through different switch settings be adapted to a variety of operating conditions. The switches are located on the circuit board and have the following functions:
S1 1-6 Selection of signal activating trans-
mitter (carrier)
S1 7-9 Selection of signal controlling CTS
F1/F2 Fuse 100mA Fast
Transmitter
(carrier) activated by
Factory settings
Always active
S1
ON
123456789
AUX
S1
ON
123456789
SRS
S1
ON
123456789
RFR
S1
ON
123456789
RTS
S1
ON
123456789
DTR
S1
ON
123456789
DTR and AUX
S1
ON
123456789
DTR and SRS
S1
ON
123456789
DTR and RFR
S1
ON
123456789
DTR and RTS
S1
ON
123456789
CTS
controlled by
RTS
S1
ON
123456789
RTS
S1
ON
123456789
Always high
S1
ON
123456789
DCD
S1
ON
123456789