Westermo Lynx-x10-F2G User Manual

User Guide
6643-2213
WeOS
Lynx
Westermo Teleindustri AB
©
Industrial Ethernet
10-port Switch
www.westermo.com
Safety
Warning
!
Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply. Note that this unit can be connected to two different power sources. When this unit is operated at an ambient temperature above +55°C (+131°F), the External Surface of Equipment may exceed Touch Temperature Limit according to EN/IEC/UL 60950-1. To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
For more information see General safety 100-5001.
Software tools
Related software tools are available in the folder software tools under technical support on the Westermo website.
License Information
This device contains public available software which is under the GPL license. For more information see legal.pdf included with all firmware releases. This product includes software developed by the OpenSSL Project for use in the
OpenSSL Toolkit. http://www.openssl.org
Legal information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
http://www.westermo.com
2
6643-2213
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
Agency approvals and standards compliance
Type Approval / Compliance
EMC EN 61000-6-1, Immunity residential environments
EN 61000-6-2, Immunity industrial environments
EN 61000-6-4, Emission industrial environments
EN 55022 +A1, Emission IT equipment
EN 55024, Immunity IT equipment
FCC part 15 Class A
EN 50121-4, Railway signalling and telecommunications apparatus
IEC 62236-4, Railway signalling and telecommunications apparatus
Safety UL/IEC/EN 60950-1, IT equipment
Marine DNV Standard for Certification no. 2.4
FCC Part 15.105 Notice:
Corrosive environment
Notice:
6643-2213
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This product has been successfully tested in a corrosion test according to IEC 60068-2-60, method 3. This means that the product meets the requirements to be placed in an environment classified as ISA-S71.04 class G3.
Note! If the product is placed in a corrosive environment, it is important that all un-used connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated pins in connectors.
3
Declaration of Conformity
Org.nr/
th
Westermo Teleindustri AB
Declaration of conformity
The manufacturer
Herewith declares that the product(s)
Type of product Model 1
Ethernet switch Lynx L*10-F2G*
is in conformity with the following EC directive(s).
No Short name
2004/108/EC Electromagnetic Compatibility (EMC) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and
References of standards applied for this EC declaration of conformity.
No Title Issue
EN 61000-6-1 Electromagnetic compatibility – Immunity for residential
EN 61000-6-2 Electromagnetic compatibility – Immunity for industrial
EN 61000-6-4 Electromagnetic compatibility – Emission for industrial
EN 55024 Information technology equipment - Immunity 1998
EN 55022 Information technology equipment - Emission 2006
EN 50121-4 Railway applications - Electromagnetic compatibility
The last two digits of the year in which the CE marking was affixed: 13
Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden
electronic equipment (RoHS)
environments
environments
environments
Emission and immunity of the signalling and telecommunications apparatus
2007
2005
2007
+A1:2001 +A2:2003
+A1:2007 2006
Pierre Öberg Technical Manager
Mars 2013
18
1
The first “*” in the model name can be any alphanumeric character, indicating software version. The second “*” in the
model name can be any alphanumeric characters indicating customer specific models, or blank.
Postadress/Postal address
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
Tel.
Telefax
Postgiro
Bankgiro Corp. identity number Registered office
4
6643-2213
Type tests and environmental conditions
Environmental phenomena Basic standard Description Test levels
ESD EN 61000-4-2 Enclosure Contact: ±6 kV
Fast transients EN 61000-4-4 Power port ±2 kV
Surge EN 61000-4-5 Power port L-E: ±0.5 kV, 12 Ω, 9 μF
Power frequency magnetic field EN 61000-4-8 Enclosure 300 A/m; 0, 16.7, 50 Hz Pulsed magnetic field EN 61000-4-9 Enclosure 300 A/m Radiated RF immunity EN 61000-4-3 Enclosure 10 V/m @ (80 – 800) MHz
Conducted RF immunity EN 61000-4-6 Power port 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Radiated RF emission EN 55022 Enclosure Class A
Conducted RF emission EN 55022 Power port Class B
Dielectric strength EN 60950-1 Power port to all
Environmental
Temperatures Operating –40 to +70°C (–40 to +158°F)*
Humidity Operating 5 to 95 % relative humidity
Altitude Operating 2 000 m / 70 kPa Service life Operating 10 year Reliability prediction (MTBF) MIL-HDBK- 217F Operating 630 000 hours Vibration IEC 60068-2-6
Shock IEC 60068-2-27 Operating 30 g, 11 ms
Bump IEC 60068-2-27 Operating 10 g, 11 ms
Packaging
Enclosure EN 60950-1 Zinc Fire enclosure Dimension W x H x D With connectors Weight 0.7 kg Degree of protection EN 60529 Enclosure IP 40 Cooling Convection
** Refer to “Safety” section.
** Might require Ethernet cables to be fastened close to the unit.
FCC Part 15 Class A
(sine)
Signal ports ±2 kV Earth port ±1 kV
Signal ports L-E: ±1 kV, 2 Ω
Signal ports 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz Earth port 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Signal ports Class B
other ports Signal ports to all
other ports
Storage and transport –50 to +85°C (–58 to +185°F)
Storage and transport 5 to 95 % relative humidity
Operating 3 – 13.2 Hz: 1mm
Air: ±8 kV
L-L: ±0.5 kV, 2 Ω, 18 μF L-E: ±2 kV, 42 Ω, 0.5 μF L-L: ±2 kV, 42 Ω, 0.5 μF L-E: ±2 kV, 12 Ω, 9 μF L-L: ±1 kV, 12 Ω, 9 μF
L-E: ±2 kV, 42Ω, 0.5 μF
20 V/m @ (800 – 1000) MHz 10 V/m @ (1400 – 2100) MHz 5 V/m @ (2100 – 2500) MHz 1 V/m @ (2500 – 2700) MHz 1 kHz sine, 80% AM
1.5 kVrms, 50 Hz, 1 min
1.5 kVrms, 50 Hz, 1 min
13.2 – 100 Hz: 0.7 g
100 g, 6 ms**
52.5 x 100 x 101 mm
52.5 x 119 x 101 mm
5.5 – 30 Hz: 1.5 g 30 – 50 Hz: 0.42 mm 50 – 500 Hz: 4.2 g**
6643-2213
5
Loading...