Westermo Lynx-x08-F2G-S2-EX User Manual

User Guide
6643-22701
WeOS
Lynx DSS
Westermo Teleindustri AB
©
Industrial Ethernet
8-port Device Server Switch
www.westermo.com
Safety
Warning
!
Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply. Note that this unit can be connected to two different power sources. When this unit is operated at an ambient temperature above +55°C (+131°F), the External Surface of Equipment may exceed Touch Temperature Limit according to EN/IEC/UL 60950-1. To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
For more information see General safety 100-5001.
Software tools
Related software tools are available in the folder software tools under technical support on the Westermo website.
License Information
This device contains public available software which is under the GPL license. For more information see legal.pdf included with all firmware releases. This product includes software developed by the OpenSSL Project for use in the
OpenSSL Toolkit. http://www.openssl.org
Legal information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
http://www.westermo.com
2
6643-22701
ATEX certification
ATEX certification number
Baseefa12ATEX0119X
Standards
EN 60079-0:2012, EN 60079-15:2010, EN 60079-28:2007
Certification code
Ex nA [op is T4] IIC T3 Gc (–40°C Ta +70°C)
ATEX code
II 3G
Specific Conditions of Use
The equipment must be installed in an area of not more than pollution degree 2 in accordance with IEC/EN 60664-1, and in an enclosure that provides a minimum degree of protection of at least IP54 and complies with the relevant requirements of EN 60079-0 and EN 60079-15.
All external connections to the equipment and, where applicable, the SFP modules must not be inserted or removed unless either the area in which the equipment is installed is known to be non-hazardous, or the circuits connected have been de-energized.
The network cables once installed must be properly fixated by the use of cable ties or similar to reduce the risk of accidently withdrawing the plugs.
Equipment input parameters
Power Connector: +DC1, +DC2 & –COM Working Voltage Range = 24 V to 48 VDC. I/O Connector: ‘Status +’ & ‘Status –’ and ‘Digital in +’ and ‘Digital in –’ Maximum I/P Voltage = 60 VDC.
6643-22701
3
SFP option approved transceivers
SFP Transceivers, 100 Mbit
1100-0131 MLC2, Multimode, LC-Connector, 2 km, 1310 nm
1100-0132 SLC20, Singlemode, LC-Connector, 20 km, 1310 nm
1100-0133 SLC40, Singlemode, LC-Connector, 40 km, 1310 nm
1100-0134 SLC80, Singlemode, LC-Connector, 80 km, 1550 nm
1100-0140 SLC120, Singlemode, LC-Connector, 120 km, 1550 nm
BiDi Transceivers, 100 Mbit
1100-0145 SLC15-BiDi-A, Singlemode, BiDi, 20 km, 1310 nm TX, 1550 nm RX
1100-0146 SLC15-BiDi-B, Singlemode, BiDi, 20 km, 1550 nm TX, 1310 nm RX
1100-0152 MLC2-BiDi-A, Multimode, BiDi, 2 km, 1310 nm TX, 1550 nm RX
1100-0153 MLC2-BiDi-B, Multimode, BiDi, 2 km, 1550 nm TX, 1310 nm RX
SFP Transceivers, 1 Gbit
1100-0144 GMLC550-SX, Multimode, LC-Connector, 550 m, 850 nm, SX
1100-0147 GMLC2-SX+, Multimode, LC-Connector, 2 km, 1310 nm, SX+
1100-0141 GSLC10-LX, Singlemode, LC-Connector, 10 km, 1310 nm, LX
1100-0142 GSLC50-XD, Singlemode, LC-Connector, 50 km, 1550 nm, XD
1100-0143 GSLC80-ZX, Singlemode, LC-Connector, 80 km, 1550 nm, ZX
1100-0171 GSLC110-EZX, Singlemode, LC-Connector, 110 km, 1550 nm, EZX
BiDi Transceiver, 1 Gbit
1100-0156 GSLC20-BiDi-A, Singlemode, BiDi, 20 km, 1310 nm TX, 1490 nm RX
1100-0157 GSLC20-BiDi-B, Singlemode, BiDi, 20 km, 1490 nm TX, 1310 nm RX
Copper Transceiver, 1 Gbit
1100-0148 GC100, Copper, RJ45, 100 m, 1000BaseT
4
6643-22701
ATEX-Zertifizierung
ATEX-Zulassungsnummer
Baseefa12ATEX0119X
Standards
EN 60079-0:2012, EN 60079-15:2010, EN 60079-28:2007
Zertifizierungscode
Ex nA [op ist T4] IIC T3 Gc (–40 °C Ta +70 °C)
ATEX-Code
II 3G
Spezifische Einsatzbedingungen
Die Geräte müssen in einem Bereich welcher einem maximalen Verschmutzungsgrad der Stufe 2 gemäß IEC/EN 60664-1 entspricht und in einem Gehäuse, das einen Schutzgrad von mindestens IP54 bietet und die relevanten Anforderungen von N 60079-0 und EN 60079-15 erfüllt, installiert werden.
Alle äußeren Anschlüsse des Gerätes und auch die SFP-Module dürfen nur dann verbunden oder getrennt werden, wenn entweder der Bereich, in dem das Gerät installiert ist, nachweislich ungefährlich ist, oder die verbundenen Stromkreise spannungsfrei sind.
Die Netzwerkkabel müssen nach der Installation mithilfe von Kabelbindern oder ähnlichem Material ordnungsgemäß befestigt werden, um ein versehentliches Abziehen der Stecker zu verhindern.
Eingangsparameter der Geräte
Stromversorgung: +DC1, +DC2 & –COM Betriebsspannungsbereich = 24 V to 48 VDC. I/O-Anschluss: ‘Status +’ & ‘Status –’ und ‘Digital in +’ und ‘Digital in –’ Maximale I/P-Spannung = 60 VDC.
6643-22701
5
Für SFP-Option zugelassene Transceiver
SFP-Transceiver, 100 Mbit
1100-0131 MLC2, Multimode, LC-Anschluss, 2 km, 1310 nm
1100-0132 SLC20, Singlemode, LC-Anschluss, 20 km, 1310 nm
1100-0133 SLC40, Singlemode, LC-Anschluss, 40 km, 1310 nm
1100-0134 SLC80, Singlemode, LC-Anschluss, 80 km, 1550 nm
1100-0140 SLC120, Singlemode, LC-Anschluss, 120 km, 1550 nm
BiDi-Transceiver, 100 Mbit
1100-0145 SLC15-BiDi-A, Singlemode, BiDi, 20 km, 1310 nm TX, 1550 nm RX
1100-0146 SLC15-BiDi-B, Singlemode, BiDi, 20 km, 1550 nm TX, 1310 nm RX
1100-0152 MLC2-BiDi-A, Multimode, BiDi, 2 km, 1310 nm TX, 1550 nm RX
1100-0153 MLC2-BiDi-B, Multimode, BiDi, 2 km, 1550 nm TX, 1310 nm RX
SFP-Transceiver, 1 Gbit
1100-0144 GMLC550-SX, Multimode, LC-Anschluss, 550 m, 850 nm, SX
1100-0147 GMLC2-SX+, Multimode, LC-Anschluss, 2 km, 1310 nm, SX+
1100-0141 GSLC10-LX, Singlemode, LC-Anschluss, 10 km, 1310 nm, LX
1100-0142 GSLC50-XD, Singlemode, LC-Anschluss, 50 km, 1550 nm, XD
1100-0143 GSLC80-ZX, Singlemode, LC-Anschluss, 80 km, 1550 nm, ZX
1100-0171 GSLC110-EZX, Singlemode, LC-Anschluss, 110 km, 1550 nm, EZX
BiDi-Transceiver, 1 Gbit
1100-0156 GSLC20-BiDi-A, Singlemode, BiDi, 20 km, 1310 nm TX, 1490 nm RX
1100-0157 GSLC20-BiDi-B, Singlemode, BiDi, 20 km, 1490 nm TX, 1310 nm RX
Kupfer-Transceiver, 1 Gbit
1100-0148 GC100, Kupfer, RJ45, 100 m, 1000BaseT
6
6643-22701
Certification ATEX
Numéro de certification ATEX
Baseefa12ATEX0119X
Normes
EN 60079-0:2012, EN 60079-15:2010, EN 60079-28:2007
Code de certification
Ex nA [op is T4] IIC T3 Gc (–40°C Ta +70°C)
Code ATEX
II 3G
Conditions spéciales d'utilisation
L'équipement doit être installé dans une zone où le degré de pollution ne dépasse pas le degré 2 conformément à l'IEC/EN 60664-1, et dans un boîtier qui fournit un niveau de protection au moins égal à IP54 et conforme aux exigences applicables à EN 60079-0 et EN 60079-15
Toutes les connexions externes à l'équipement et, le cas échéant, les modules SFP ne doivent pas être insérés ou retirés sauf si la zone dans laquelle l'équipement est installé est reconnue comme non dangereuse, ou si les circuits raccordés sont hors-tension.
Une fois les câbles réseau installés, ils doivent être correctement fixé grâce à des attaches de câbles ou autre élément semblable afin de réduire le risque de débranchement accidentel.
Paramètres d'entrée des équipements
Connecteur d'alimentation : +DC1, +DC2 & –COM Double entrée d'alimentation 24 V à 48 VCC Connecteur E/S : « Statut + » et « Statut – » et « Entrée digitale + » et « Entrée digitale – » Tension maximale I/P = 60 VCC.
6643-22701
7
Transmetteurs optionnels SFP certifiés
Transmetteurs SFP, 100 Mbit
1100-0131 MLC2, multimode, connecteur LC, 2 km, 1310 nm
1100-0132 SLC20, monomode, connecteur LC, 20 km, 1310 nm
1100-0133 SLC40, monomode, connecteur LC, 40 km, 1310 nm
1100-0134 SLC80, monomode, connecteur LC, 80 km, 1550 nm
1100-0140 SLC120, monomode, connecteur LC, 120 km, 1550 nm
Transmetteurs Bi-Di, 100 Mbit
1100-0145 SLC15 Bi-Di A, monomode, Bi-Di, 20 km, 1310 nm TX, 1550 nm, RX
1100-0146 SLC15-Bi-Di-B, monomode, Bi-Di, 20 km, 1550 nm TX, 1310 nm RX
1100-0152 MLC2-BiDi-A, multimode, Bi-Di, 2 km, 1310 nm TX, 1550 nm RX
1100-0153 MLC2-BiDi-B, multimode, Bi-Di, 2 km, 1550 nm TX, 1310 nm RX
Transmetteurs SFP, 1 Gbit
1100-0144 GMLC550-SX, multimode, connecteur LC, 550 m, 850 nm, SX
1100-0147 GMLC2-SX+, multimode, connecteur LC, 2 km, 1310 nm, SX+
1100-0141 GSLC10-LX, monomode, connecteur LC, 10 km, 1310 nm, LX
1100-0142 GSLC50-XD, monomode, connecteur LC, 50 km, 1550 nm, XD
1100-0143 SLC80, monomode, connecteur LC, 80 km, 1550 nm, ZX
1100-0171 GSLC110, monomode, connecteur LC, 110 km, 1550 nm, EZX
Transmetteurs Bi-Di, 1 Gbit
1100-0156 GSLC20-BiDi-A, monomode, Bi-Di, 20 km, 1310 nm TX, 1490 nm RX
1100-0157 GSLC20-BiDi-B, monomode, Bi-Di, 20 km, 1490 nm TX, 1310 nm RX
Transmetteurs cuivre, 1 Gbit
1100-0148 GC100, cuivre, RJ45, 100 m, 1000BaseT
8
6643-22701
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
Agency approvals and standards compliance
Type Approval / Compliance
EMC EN 61000-6-1, Immunity residential environments
EN 61000-6-2, Immunity industrial environments
EN 61000-6-3, Emission residential environments
EN 61000-6-4, Emission industrial environments
EN 55022 +A1, Emission IT equipment
EN 55024 +A1 + A2, Immunity IT equipment
FCC part 15 Class B
EN 50121-4, Railway signalling and telecommunications apparatus
IEC 62236-4, Railway signalling and telecommunications apparatus
Safety UL/IEC/EN 60950-1, IT equipment
Marine DNV Standard for Certification no. 2.4
Ex EN 60079-0, EN 60079-15 and EN 60079-28
FCC Part 15.105 Notice:
Corrosive environment
Notice:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
… Reorient or relocate the receiving antenna … Increase the separation between the equipment and receiver … Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
… Consult the dealer or an experienced radio/TV technician for help.
This product has been successfully tested in a corrosion test according to IEC 60068-2-60, method 3. This means that the product meets the requirements to be placed in an environment classified as ISA-S71.04 class G3.
Note! If the product is placed in a corrosive environment, it is important that all un-used connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated pins in connectors.
6643-22701
9
Declaration of Conformity
Org.nr/
th
Westermo Teleindustri AB
The manufacturer Westermo Teleindustri AB
Herewith declares that the product(s)
Type of product Model 1
Ethernet device server switch Lynx DSS L*08-F2G-S2-EX*
is in conformity with the following EC directive(s).
No Short name
Declaration of conformity
SE-640 40 Stora Sundby, Sweden
2004/108/EC Electromagnetic Compatibility (EMC) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and
References of standards applied for this EC declaration of conformity.
No Title Issue
EN 61000-6-1 Electromagnetic compatibility – Immunity for residential
EN 61000-6-2 Electromagnetic compatibility – Immunity for industrial
EN 61000-6-3 Electromagnetic compatibility – Emission for residential
EN 61000-6-4 Electromagnetic compatibility – Emission for industrial
EN 55024 Information technology equipment - Immunity 1998
electronic equipment (RoHS)
environments
environments
environments
environments
EN 55022 Information technology equipment - Emission 2006
EN 50121-4 Railway applications - Electromagnetic compatibility
EN 60079-0 Explosive atmospheres
EN 60079-15 Electrical apparatus for explosive gas atmospheres –
EN 60079-28 Explosive atmospheres - Protection of equipment and
The last two digits of the year in which the CE marking was affixed: 13
Emission and immunity of the signalling and telecommunications apparatus
Equipment – General requirements
Construction, test and marking of type of protection “n”
transmission systems using optical radiation
2007
2005
2007
2007
+A1:2001 +A2:2003
+A1:2007 2006
2012
2010
2007
Pierre Öberg Technical Manager
December 2013
08
1
The first “*” in the model name can be any alphanumeric character, indicating software version. The second “*” in the
model name can be any alphanumeric characters indicating customer specific models, or blank.
Postadress/Postal address
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int +46 16428001
Tel.
Telefax
Postgiro
Bankgiro Corp. identity number Registered office
10
6643-22701
Product description
Status Active
Ports 6 x RJ-45, 10/100BaseT.
Description Managed Device Server Switch with routing functionality
Warranty period 5 years
Approvals
Marine DNV Standard for Certification no. 2.4
EMC (Electromagnetic Compatibility)
EN 61000-6-1 Immunity residential environments
EN 61000-6-2 Immunity industrial environments
EN 61000-6-3 Emission residential environments
EN 61000-6-4 Emission industrial environments
EN 55022 +A1 Emission IT equipment
EN 55024 + A1 + A2 Immunity IT equipment
FCC part 15 Class B
EN 50121-4 Railway signalling and telecommunications apparatus
IEC 62236-4 Railway signalling and telecommunications apparatus
EMC specifications
EN 61000-4-2, ESD
EN 61000-4-4, fast transients
EN 61000-4-5, surge
EN 61000-4-8, power frequency magnetic field
4 x SFP, 100/1000 Mbit/s. 2 x RJ-45, RS-232/422/485.
Contact: ±6 kV Air: ±8 kV
Power port: ±2 kV Ethernet: ±2 kV Status out/Digital in: ±2 kV Serial ports: ±2 kV Enclosure: ±2 kV
Power port L-L: ±0.5 kV, 2 Ω, 18 μF L-E: ±2 kV, 42 Ω, 0.5 μF L-L: ±1 kV, 42 Ω, 0.5 μF L-E: ±2 kV, 12 Ω, 9 μF L-L: ±1 kV, 12 Ω, 9 μF
Ethernet L-E: ±2 kV, 2Ω, 0.5 μF
Status out/Digital in L-E: ±2 kV, 42 Ω, 0.5 μF L-L: ±1 kV, 42 Ω, 0.5 μF
RS-232 L-E: ±2 kV, 2 Ω, 0.5 μF
RS-422/485 L-E: ±2 kV, 42 Ω, 0.5 μF
300 A/m; 0, 16.7, 60 Hz 1000 A/m; 50 Hz
6643-22701
11
EN 61000-4-9, pulsed magnetic field
EN 61000-4-3, radiated RF immunity
EN 61000-4-6, conducted RF immunity
EN 55022, radiated RF emmision, FCC Part 15/ DNV 2.4
EN 55022, conducted RF emmision,
300 A/m
20 V/m @ (80 – 2700) MHz 1 kHz sine, 80% AM
Power port: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz Ethernet: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz Ethernet: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz Status out/Digital in: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz Status out/Digital in: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz Serial ports: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz Earth port: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
EN 55022/FCC Part 15/DNV 2.4, Class B / DNV bridge
EN 55022/FCC Part 15/DNV 2.4, Class B / DNV bridge
DNV 2.4, compass safe distance
Standard compass (5.4°/H deviation) = 15 cm Steering/standby steering/emergency compass (18°/H deviation) = 10 cm
Safety
Safety UL/IEC/EN 60950-1, IT equipment
EN 60950-1, dielectric strength
Power port to all other ports: 1.5 kVrms, 50 Hz, 1 min Ethernet ports to all other ports: 1.5 kVrms, 50 Hz, 1 min RS-232 port to all other ports: 1.5 kVrms, 50 Hz, 1 min RS-422/485 port to all other ports: 1.5 kVrms, 50 Hz, 1 min
Reliability prediction
MTBF, operating 517 000 hours
Service life, operating 10 years
Climatic
Temperature, operating –40 to +70°C (–40 to +158°F)
Temperature, storage –50 to +85°C (–58 to +185°F)
Humidity, operating 5 to 95 % relative humidity
Humidity, storage 5 to 95 % relative humidity
Enclosure
Enclosure Fire enclosure
Dimensions (W x H x D) 52.5 x 100 x 101 mm
Weight 0.7 kg
Degree of protection IP 40
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail
12
6643-22701
Mechanical
IEC 60068-2-6, vibration
IEC 60068-2-6,(sine), operating 3 – 13.2 Hz: 1mm
13.2 – 100 Hz: 0.7 g
5.5 – 30 Hz: 1.5 g 30 – 50 Hz: 0.42 mm 50 – 500 Hz: 4.2 g
IEC 60068-2-64 (random), operating 5 – 20 Hz: 2 m²/s³, 20 – 2000 Hz: – 3 dB/oct
IEC-60068-2-27, shock Operating:
30 g, 11 ms 100 g, 6 ms**
IEC 60068-2-27, bump Operating:
10 g, 11 ms
Interface specifications, power
Rated voltage 24 to 48 VDC
Operating voltage 19 to 60 VDC
Rated current 250 mA (380 mA) @ 24 VDC (with 500 mA USB load)
120 mA (188 mA) @ 48 VDC (with 500 mA USB load)
Rated frequency DC
Inrush current 22.7·10-3 A²s @ 48 VDC
Startup current* 2 x Rated current
Polarity Reverse polarity protected
Redundant power input Yes
Isolation to All other
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm² (AWG 24 – 12)
Shielded cable Not required
* External supply current capability for proper start-up
Interface specifications, 10/100BaseTX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type TNV-1
Transmission range Up to 150 m with CAT5e cable or better*
Isolation to All other
Connection RJ-45, auto MDI/MDI-X
Cabling Shielded CAT5e or better is recommended
Conductive housing Ye s
Number of ports 4
* Refer to Safety section.
6643-22701
13
Interface specifications, 100/1000SFP
Optical/Electrical specification IEEE std 802.3. 2005 Edition
Data rate 100 Mbit/s or 1000 Mbit/s transceivers supported
Duplex Full or Auto, depending on transceiver
Transmission range Depending on tranceiver
Connection SFP slot holding fibre transceiver or copper transceiver
Number of ports 1 or 2
Interface specifications, RS-232
Electrical specification EIA RS-232
Data rate 300 bit/s – 115.2 kbit/s
Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
Protocol Transparent, optimised by packing algorithm
Circuit type SELV
Transmission range 15 m / 49 ft
Isolation to All other
Connection RJ-45 according to EIA-561
Shielded cable Recommended
Conductive housing Ye s
Number of ports 1
Interface specifications, RS-422/485
Electrical specification Configurable for EIA RS-232 or EIA RS-422/485
Data rate 50 bit/s – 2 Mbit/s
Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
(2 stop bits only when no parity is set)
Circuit type TNV-1
Transmission range Up to 1200 m / 0.74 mi, depending on data rate and cable
type
Isolation to All other
Connection RJ-45 according to EIA-561
Shielded cable Not required, but recommended in railway installations close
to the rails.*
Conductive housing Ye s
Number of ports 1
* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port.
14
6643-22701
Interface specifications, I/O relay output
Maximum voltage / current 60 VDC / 80 mA
Connect resistance Max 30 Ω
Isolation to All other
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm² (AWG 24 – 12)
Interface specifications, I/O Digital output
Maximum volt / current 60 VDC / 2 mA
Voltage_levels Logic one: >12V
Isolation to All other
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm² (AWG 24 – 12)
Interface specifications, USB
Electrical specification USB 2.0 host interface
Data rate Up to 12 Mbit/s (full-speed mode)
Circuit type SELV
Maximum supply current 500 mA
Connection USB receptacle connector type A
Interface specifications, console
Electrical specification LVTTL/LVCMOS-level
Data rate 115.2 kbit/s
Data format 8 data bits, no parity, 1 stop bit, no flow control
Circuit type SELV
Connection 2.5 mm jack, use only Westermo cable 1211-2027
Accessories
Description Art no
Westermo console cable 1211-2027
RJ45 to terminal block 1200-2490
RJ45 to DB9 cable 1211-2210
Logic zero: <1V
SFP Transceivers
Supported transceivers
Firmware prior to 4.4.0 accepts Westermo branded transceivers only. From 4.5.0 other transceivers are accepted with a notice and the unit will no longer be UL approved. Temp.specifications are also depending on the used transeivers.
Note: To comply with UL60950-1 only UL recognized SFP transceivers should be used.
Deviations
With copper transceiver 1100-0148 the specified operating temperature on Lynx is 0 to +50ºC (32 to +122°F).
FRNT reconfiguration times can not be guaranteed with copper transceivers.
6643-22701
15
Safety control drawing
Location of interface ports and LED’s
LED Indicators (for details see page 16)
Ethernet connection TX (4 ports)
Position Signale Direction Description Input/output values
No.1 TD+ In/Out Transmitted/Received data
No. 2 TD– In/Out Transmitted/Received data
No. 3 RD+ In/Out Transmitted/Received data
I/O connection (for details see page 11 and 15)
No. 4 Not Connected
No. 5 Not Connected
No. 6 RD– In/Out Transmitted/Received data
No. 7 Not Connected
No. 8 Not Connected
Shield Connected to PE
Galvanically isolated via signal transformers and capacitively isolated to GND/PE through a 2kV 1000pF capacitor. See user manual for proven transient protection.
Power connection (for details see page 9 and 15)
USB
Position Direction* / description Output values
1 Out / VBUS
2 In/out / D–
3 In/out / D+
4 GND
Shield PE
SFP transceivers (for details see page 11)
RS-232, RS-422/485 (for details see page 10 and 13)
U
= 5 VDC max
out
I
= 500 mA max
out
Per port: U = ± 1 V (4μV/s) I = ± 20 mA
Data rate: 10/100 Mbit/s
RJ-45 connector (Front view)
Male Female
Pin 8 Pin 1
16
Pin 8
Pin 1
Pin 1
Pin 8
6643-22701
RS-422/485 (for more details see below)
No termination
Terminate Rx Terminate Tx
Terminate Tx and Rx
Position
No. 1 T+ T+/R+ Out/In RS-422: Transmit
No. 2 T– T–/R– Out/In RS-422: Transmit
No. 3 R– In RS-422: Receive
No. 4
No. 5
No. 6 R+ In RS-422: Receive
No. 7 Not used
No. 8 Not used
Signal
RS-422
(4-wire)
RS-485
(2-wire)
Direction Description Input/Output values
RS-485: Transmit/Receive
RS-485: Transmit/Receive
Not used
Not used
U = 5 V max
I = 250 mA max
Data rate: 50 bit/s – 2 Mbit/s
RS-232
Position Signal Direction Description Input/Output values
No. 1 DSR Out Data Set Ready
No. 2 DCD Out Data Carrier Detect
No. 3 DTR In Data Terminal Ready
No. 4 SG Signal Ground, not chassis ground
No. 5 RD Out Receive Data
No. 6 TD In Transmit Data
U = ±12 V max
I = ±60 mA max
Data rate: 300 bit/s – 115.2 kbit/s
No. 7 CTS Out Clear To Send
No. 8 RTS In Request To Send
Lynx DSS is equipped with internal termination that is configurable through software in RS-422/485 mode. The following termination schemes are supported:
Tx
Tx
Tx
Tx
RS-422
Rx
No termination
Rx
Rx
Termination
Rx
RS-485
When the unit is powered-off or during reboot, any internal termination will be disconnected from the signal lines.
Note: Due to that the port is configurable for both RS-232 and RS-422/485, there are no fail-safe biasing available for RS-422/485 signals.
6643-22701
17
Safety control drawing
I/O connection (for details see page 11)
Console port (for details see page 11 and 15)
Bottom view
Cable 1211-2027
Connection to console port
The console port can be used to connect to the CLI (Command Line Interface).
The following steps needs to be taken
1. Connect the serial diagnostic cable to the console port (use only Westermo cable 1211-2027).
2. Connect cable to your computer (USB port, if drivers are needed they can be downloaded from our Web page).
3. Use a terminal emulator and connect with correct speed and format (115200, 8N1) to the assigned port.
For more information about the CLI, see the WeOS management guide.
18
6643-22701
Safety control drawing
Power connection
4-position
1
No. 1 +DC1 Input Supply voltage input DC1
2
No. 2 +DC2 Input Supply voltage input DC2
3
4
No. 3 -COM Input Common
No. 4 -COM Input Common
Lynx supports redundant power connection. The positive inputs are +DC1 and +DC2, the negative input for both supplies are –COM. Connect the primary voltage (e.g. +24 VDC) to the +DC1 pin and return to one of the –COM pins on the power input.
I/O connection
4-position
1
2
3
4
No. 1 Status + Output Alarm relay (status) contact Uin = 60 VDC max
No. 2 Status – Output Alarm relay (status) contact Iin = 80 mA max
No. 3 Digital in + Input Digital in + Uin = 60 VDC max
No. 4 Digital in – Input Digital in – Iin = 2 mA max
The Status output is a potential free, opto-isolated normally closed solid-state relay. This can be configured to monitor various alarm events within the Lynx unit, see WeOS Management Guide. An external load in series with an external voltage source is required for proper functionality. For voltage/current ratings, see Interface Specification section.
Console port
Position Direction* / description Input/output values
No.1 In / out / GND
No. 2 Out / Tx
No. 3 In / Rx
* Direction relative to this unit.
Product marking
Product marking
U = 3.3 VDC max I = 24 mA max
Direction Description Input values
Direction Description Input / Output values
Uin = (19 – 60) VDC Iin = 380 mA @ 24 VDC PIn = 9.1 W @ 24 VDC
The Digital in is an opto-isolated digital input which can be used to monitor external events. For volt­age/current ratings, see Interface Specification section:
6643-22701
Lynx
External Load
1
Status
2
3
4
V
+
V
Digital In
19
LED indicators
LED Status Description
ON OFF Unit has no power.
GREEN All OK, no alarm condition.
RED Alarm condition, or until unit has started up.
BLINK Location indicator ("Here I am!"). Activated when
DC1
DC2 OFF Unit has no power.
FRNT OFF FRNT disabled.
RSTP
USR1 OFF
Rx/TD, TD OFF No serial data received.
Tx/RD, RD OFF No serial data transmitted.
1 to 6 OFF No Link.
OFF Unit has no power.
GREEN
RED Power failure on +DC1.
GREEN Power OK on DC2.
RED Power failure on +DC2.
GREEN FRNT OK.
RED FRNT Error.
BLINK Unit configured as FRNT Focal Point.
OFF RSTP disabled.
GREEN RSTP enabled.
BLINK Unit elected as RSTP/STP root switch.
RED
GREEN FLASH
GREEN FLASH
GREEN Link established.
GREEN FLASH
YELLOW Port alarm and no link. Or if FRNT or RSTP mode,
(Alarm conditions are configurable, see ''WeOS Management Guide'').
connected to IPConfig Tool, or upon request from Web or CLI.
Power OK on DC1.
Configurable, see WeOS Management Guide.GREEN
Serial data received.
Serial data transmitted.
Data traffic indication.
port is blocked.
20
6643-22701
Mounting
This unit should be mounted on 35 mm DIN-rail, which is horizontally mounted inside an apparatus cabinet or similar. It is recommended that the DIN-rail is connected to ground. Snap on mounting, see figure.
Mounting Lynx with integrated DIN-clip:
Removal
Removing Lynx with integrated DIN-clip: Press down the support at the back of the unit using a screwdriver. See figure.
Cooling
This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Minimum spacing 25 mm (1.0 inch) above / below and 10 mm (0.4 inches) left / right the unit. Spacing is recommended for the use of unit in full operating temperature range and service life.
6643-22701
10mm 10mm
21
Getting Started
This product runs Westermo Operating System (WeOS) which provides several management tools that can be used for configuration of the unit.
• IPConfig tool
This is a custom Westermo tool used for discovery of attached Westermo units.
Note! Version of IP Config tool must be 10.4.0 or higher.
• Web
Configuration of the unit using the web browser.
• CLI Configuration of the unit via the Command Line Interface.
Username: admin Password: westermo
If the computer is located in the same subnet as the switch you can easily use a web browser to configure the unit. Within the web you can configure most of the available functions.
For advanced network settings and more diagnostic information, please use the CLI. Detailed documentation is available in the chapter The Command Line Management Tool in the WeOS management guide.
Factory default IP address: 192.168.2.200 Netmask: 255.255.255.0 Gateway: Disabled
Note! If you are not sure about the subnet – consult your network administrator.
Configuration
Configure the unit via Web browser
The unit can easily be configured via a Web browser. Open the link http://192.168.2.200 in your web browser, and you will be prompted with a Login screen, where the default settings for Username and Password are:
Username: admin Password: westermo
Once you have logged in, you can use the extensive integrated help function describing all configuration options. Two common task when configuring a new switch is to assign appropriate IP settings, and to change the password of the admin account. The password can be up to 64 characters long, and should consist of printable ASCII characters (ASCII 33-126); 'Space' is not a valid password character.
22
6643-22701
Referring documents
Type Description Document number
Management Guide Westermo OS management guide
6101-3201
Factory default on L108-F2G-S2 EX / L208-F2G-S2 EX
It is possible to set the unit to factory default settings by using two straight standard Ethernet RJ-45 cables.
1. Power off the switch and disconnect all Ethernet cables (copper and fibre).
2. Connect one Ethernet cable between Ethernet ports 3 and 6, and the other between Ethernet ports 4 and 5. The ports need to be connected directly by an Ethernet cable, i.e., not via a hub or switch. Use a straight cable – not a cross-over cable – when connecting the ports.
3. Power on the unit.
4. Wait for the unit to start up. Control that the ON LED is flashing red.
The ON LED flashing indicates that the unit is now ready to be reset to factory
default. You now have the choice to go ahead with the factory reset, or to skip factory reset and boot as normal.
• Go ahead with factory reset:
Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cables. The ON LED will stop flashing. This initiates the factory reset process*, and after approximately 1 minute the unit will restart with factory default settings. When the switch has booted up, the ON LED will show a green light, and is now ready to use.
• Skip the factory reset:
To skip the factory reset process, just wait for approximately 30 seconds (after the ON LED starts flashing RED) without unplugging the Ethernet cables. The switch will conduct a normal boot with the existing settings.
* Note Do not power off the unit while the factory reset process is in progress.
6643-22701
23
Westermo • SE-640 40 Stora Sundby, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
Sales Units
Westermo Data Communications
E-mail: info@westermo.com
www.westermo.com
China sales.cn@westermo.com www.cn.westermo.com
France infos@westermo.fr www.westermo.fr
Germany info@westermo.de www.westermo.de
For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code
REV.B 6643-22701 2015-01 Westermo Teleindustri AB, Sweden – A Beijer Electronics Group Company
North America
info@westermo.com www.westermo.com
Singapore sales@westermo.com.sg www.westermo.com
Sweden
info.sverige@westermo.se www.westermo.se
United Kingdom sales@westermo.co.uk www.westermo.co.uk
Other Offices
Loading...