Westermo Lynx-x05-S1-EX User Manual

User Guide
6643-22801
WeOS
Lynx DSS
Westermo Teleindustri AB
©
Industrial Ethernet
5-port Device Server Switch
www.westermo.com
Safety
Warning
!
Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply. Note that this unit can be connected to two different power sources. When this unit is operated at an ambient temperature above +55°C (+131°F), the External Surface of Equipment may exceed Touch Temperature Limit according to EN/IEC/UL 60950-1. To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
For more information see General safety 100-5001.
Software tools
Related software tools are available in the folder software tools under technical support on the Westermo website.
License Information
This device contains public available software which is under the GPL license. For more information see legal.pdf included with all firmware releases. This product includes software developed by the OpenSSL Project for use in the
OpenSSL Toolkit. http://www.openssl.org
Legal information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
http://www.westermo.com
2
6643-22801
ATEX certification
ATEX certification number
Baseefa12ATEX0119X
Standards
EN 60079-0:2012, EN 60079-15:2010.
Certification code
Ex nA IIC T3 Gc (–40°C Ta +70°C)
ATEX code
II 3G
Specific Conditions of Use
The equipment must be installed in an area of not more than pollution degree 2 in accordance with IEC/EN 60664-1, and in an enclosure that provides a minimum degree of protection of at least IP54 and complies with the relevant requirements of EN 60079-0 and EN 60079-15.
All external connections to the equipment and, where applicable, the SFP modules must not be inserted or removed unless either the area in which the equipment is installed is known to be non-hazardous, or the circuits connected have been de-energized.
The network cables once installed must be properly fixated by the use of cable ties or similar to reduce the risk of accidently withdrawing the plugs.
Equipment input parameters
Power Connector: +DC1, +DC2 & –COM Working Voltage Range = 24 V to 48 VDC. I/O Connector: ‘Status +’ & ‘Status –’ and ‘Digital in +’ and ‘Digital in –’ Maximum I/P Voltage = 60 VDC.
6643-22801
3
ATEX-Zertifizierung
ATEX-Zulassungsnummer
Baseefa12ATEX0119X
Standards
EN 60079-0:2012, EN 60079-15:2010
Zertifizierungscode
Ex nA [op ist T4] IIC T3 Gc (–40 °C Ta ≤ +70 °C)
ATEX-Code
II 3G
Spezifische Einsatzbedingungen
Die Geräte müssen in einem Bereich welcher einem maximalen Verschmutzungsgrad der Stufe 2 gemäß IEC/EN 60664-1 entspricht und in einem Gehäuse, das einen Schutzgrad von mindestens IP54 bietet und die relevanten Anforderungen von N 60079-0 und EN 60079-15 erfüllt, installiert werden.
Alle äußeren Anschlüsse des Gerätes und auch die SFP-Module dürfen nur dann verbunden oder getrennt werden, wenn entweder der Bereich, in dem das Gerät installiert ist, nachweislich ungefährlich ist, oder die verbundenen Stromkreise spannungsfrei sind.
Die Netzwerkkabel müssen nach der Installation mithilfe von Kabelbindern oder ähnlichem Material ordnungsgemäß befestigt werden, um ein versehentliches Abziehen der Stecker zu verhindern.
Eingangsparameter der Geräte
Stromversorgung: +DC1, +DC2 & –COM Betriebsspannungsbereich = 24 V to 48 VDC. I/O-Anschluss: ‘Status +’ & ‘Status –’ und ‘Digital in +’ und ‘Digital in –’ Maximale I/P-Spannung = 60 VDC.
4
6643-22801
Certification ATEX
Numéro de certification ATEX
Baseefa12ATEX0119X
Normes
EN 60079-0:2012, EN 60079-15:2010
Code de certification
Ex nA [op is T4] IIC T3 Gc (–40°C Ta +70°C)
Code ATEX
II 3G
Conditions spéciales d'utilisation
L'équipement doit être installé dans une zone où le degré de pollution ne dépasse pas le degré 2 conformément à l'IEC/EN 60664-1, et dans un boîtier qui fournit un niveau de protection au moins égal à IP54 et conforme aux exigences applicables à EN 60079-0 et EN 60079-15
Toutes les connexions externes à l'équipement et, le cas échéant, les modules SFP ne doivent pas être insérés ou retirés sauf si la zone dans laquelle l'équipement est installé est reconnue comme non dangereuse, ou si les circuits raccordés sont hors-tension.
Une fois les câbles réseau installés, ils doivent être correctement fixé grâce à des attaches de câbles ou autre élément semblable afin de réduire le risque de débranchement accidentel.
Paramètres d'entrée des équipements
Connecteur d'alimentation : +DC1, +DC2 & –COM Double entrée d'alimentation 24 V à 48 VCC Connecteur E/S : « Statut + » et « Statut – » et « Entrée digitale + » et « Entrée digitale – » Tension maximale I/P = 60 VCC.
6643-22801
5
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
Agency approvals and standards compliance
Type Approval / Compliance
EMC EN 61000-6-1, Immunity residential environments
EN 61000-6-2, Immunity industrial environments
EN 61000-6-3, Emission residential environments
EN 61000-6-4, Emission industrial environments
EN 55022 +A1, Emission IT equipment
EN 55024 +A1 + A2, Immunity IT equipment
FCC part 15 Class B
EN 50121-4, Railway signalling and telecommunications apparatus
IEC 62236-4, Railway signalling and telecommunications apparatus
Safety UL/IEC/EN 60950-1, IT equipment
Marine DNV Standard for Certification no. 2.4
Ex EN 60079-0 and EN 60079-15
FCC Part 15.105 Notice:
Corrosive environment
Notice:
6
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
… Reorient or relocate the receiving antenna … Increase the separation between the equipment and receiver … Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
… Consult the dealer or an experienced radio/TV technician for help.
This product has been successfully tested in a corrosion test according to IEC 60068- 2-60, method 3. This means that the product meets the requirements to be placed in an environment classified as ISA-S71.04 class G3.
Note! If the product is placed in a corrosive environment, it is important that all un-used connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated pins in connectors.
6643-22801
Declaration of Conformity
Org.nr/
th
Westermo Teleindustri AB
Declaration of conformity
The manufacturer
Herewith declares that the product(s)
Type of product Model 1
Industrial Ethernet 5-port Device Server Switch Lynx DSS L*05-S1-EX*
is in conformity with the following EC directive(s).
No Short name
2004/108/EC Electromagnetic Compatibility (EMC) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and
References of standards applied for this EC declaration of conformity.
No Title Issue EN 61000-6-1 Electromagnetic compatibility – Immunity for residential
EN 61000-6-2 Electromagnetic compatibility – Immunity for industrial
EN 61000-6-3 Electromagnetic compatibility – Emission for residential
EN 61000-6-4 Electromagnetic compatibility – Emission for industrial
EN 55024 Information technology equipment - Immunity 1998
EN 55022 Information technology equipment - Emission 2006
EN 50121-4 Railway applications - Electromagnetic compatibility
EN 60079-0 Explosive atmospheres
EN 60079-15 Electrical apparatus for explosive gas atmospheres –
The last two digits of the year in which the CE marking was affixed: 13
Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden
electronic equipment (RoHS)
environments
environments
environments
environments
Emission and immunity of the signalling and telecommunications apparatus
Equipment – General requirements
Construction, test and marking of type of protection “n”
2007
2005
2007 +A1:2011 2007 +A1:2011
+A1:2001 +A2:2003
+A1:2007 2006
2012
2010
Pierre Öberg Technical Manager
December 2013
08
1
The first “*” in the model name can be any alphanumeric character, indicating software version. The second “*” in the
model name can be any alphanumeric characters indicating customer specific models, or blank.
Postadress/Postal address
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
Tel.
Telefax
Postgiro
Bankgiro Corp. identity number Registered office
6643-22801
7
Type tests and environmental conditions
Environmental phenomena Basic standard Description Test levels
Electrostatic discharge EN 61000-4-2 Enclosure Contact: ±6 kV
Fast transients EN 61000-4-4 Power port ±2 kV
Surge EN 61000-4-5 Power port L-L: ±0.5 kV, 2 Ω, 18 μF
Power frequency magnetic field EN 61000-4-8 Enclosure 300 A/m; 0, 16.7, 60 Hz
Pulsed magnetic field EN 61000-4-9 Enclosure 300 A/m Radiated RF immunity EN 61000-4-3 Enclosure 20 V/m @ (80 – 2700) MHz
Conducted RF immunity EN 61000-4-6 Power port 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Radiated RF emission EN 55022/
Conducted RF emission EN 55022/
Compass safe distance DNV 2.4 Enclosure Standard compass (5.4°/H deviation) =
Dielectric strength EN 60950-1 Power port to all
FCC Part 15/ DNV 2.4
FCC Part 15/ DNV 2.4
Ethernet Status out/Digital in Serial ports Enclosure
Ethernet L-E: ±2 kV, 2Ω, 0.5 μF Status out/Digital in L-E: ±2 kV, 42 Ω, 0.5 μF
RS-232 L-E: ±2 kV, 2 Ω, 0.5 μF
Ethernet Status out/Digital in Serial ports Earth port Enclosure Class B / DNV bridge
Power port Class B / DNV bridge Ethernet Class B
other ports Ethernet ports to all
other ports RS-232 port to all
other ports
Air: ±8 kV
L-E: ±2 kV, 42 Ω, 0.5 μF L-L: ±1 kV, 42 Ω, 0.5 μF L-E: ±2 kV, 12 Ω, 9 μF L-L: ±1 kV, 12 Ω, 9 μF
L-L: ±1 kV, 42 Ω, 0.5 μF
1000 A/m; 50 Hz
1 kHz sine, 80% AM
15 cm Steering/standby steering/emergency com­pass (18°/H deviation) = 10 cm
1.5 kVrms, 50 Hz, 1 min
8
6643-22801
Loading...