Do not open connected unit. Hazardous voltage may occur within this unit when
connected to power supply.
Note that this unit can be connected to two different power sources.
When this unit is operated at an ambient temperature above +55°C (+131°F),
the External Surface of Equipment may exceed Touch Temperature Limit according
to EN/IEC/UL 60950-1.
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication
line cord.
For more information see General safety 100-5001.
Software tools
Related software tools are available in the folder software tools under
technical support on the Westermo website.
License Information
This device contains public available software which is under the GPL license.
For more information see legal.pdf included with all firmware releases.
This product includes software developed by the OpenSSL Project for use in the
OpenSSL Toolkit. http://www.openssl.org
Legal information
The contents of this document are provided “as is”. Except as required by applicable
law, no warranties of any kind, either express or implied, including, but not limited to,
the implied warranties of merchantability and fitness for a particular purpose, are made
in relation to the accuracy and reliability or contents of this document. Westermo
reserves the right to revise this document or withdraw it at any time without prior
notice.
Under no circumstances shall Westermo be responsible for any loss of data or income
or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
http://www.westermo.com
2
6643-22801
ATEX certification
ATEX certification number
Baseefa12ATEX0119X
Standards
EN 60079-0:2012, EN 60079-15:2010.
Certification code
Ex nA IIC T3 Gc (–40°C ≤ Ta ≤ +70°C)
ATEX code
II 3G
Specific Conditions of Use
The equipment must be installed in an area of not more than pollution degree 2 in
accordance with IEC/EN 60664-1, and in an enclosure that provides a minimum degree of
protection of at least IP54 and complies with the relevant requirements of EN 60079-0
and EN 60079-15.
All external connections to the equipment and, where applicable, the SFP modules must
not be inserted or removed unless either the area in which the equipment is installed is
known to be non-hazardous, or the circuits connected have been de-energized.
The network cables once installed must be properly fixated by the use of cable ties or
similar to reduce the risk of accidently withdrawing the plugs.
Equipment input parameters
Power Connector: +DC1, +DC2 & –COM
Working Voltage Range = 24 V to 48 VDC.
I/O Connector: ‘Status +’ & ‘Status –’ and ‘Digital in +’ and ‘Digital in –’
Maximum I/P Voltage = 60 VDC.
6643-22801
3
ATEX-Zertifizierung
ATEX-Zulassungsnummer
Baseefa12ATEX0119X
Standards
EN 60079-0:2012, EN 60079-15:2010
Zertifizierungscode
Ex nA [op ist T4] IIC T3 Gc (–40 °C ≤ Ta ≤ +70 °C)
ATEX-Code
II 3G
Spezifische Einsatzbedingungen
Die Geräte müssen in einem Bereich welcher einem maximalen Verschmutzungsgrad der
Stufe 2 gemäß IEC/EN 60664-1 entspricht und in einem Gehäuse, das einen Schutzgrad
von mindestens IP54 bietet und die relevanten Anforderungen von N 60079-0 und EN
60079-15 erfüllt, installiert werden.
Alle äußeren Anschlüsse des Gerätes und auch die SFP-Module dürfen nur dann
verbunden oder getrennt werden, wenn entweder der Bereich, in dem das Gerät
installiert ist, nachweislich ungefährlich ist, oder die verbundenen Stromkreise
spannungsfrei sind.
Die Netzwerkkabel müssen nach der Installation mithilfe von Kabelbindern oder
ähnlichem Material ordnungsgemäß befestigt werden, um ein versehentliches Abziehen
der Stecker zu verhindern.
Eingangsparameter der Geräte
Stromversorgung: +DC1, +DC2 & –COM
Betriebsspannungsbereich = 24 V to 48 VDC.
I/O-Anschluss: ‘Status +’ & ‘Status –’ und ‘Digital in +’ und ‘Digital in –’
Maximale I/P-Spannung = 60 VDC.
4
6643-22801
Certification ATEX
Numéro de certification ATEX
Baseefa12ATEX0119X
Normes
EN 60079-0:2012, EN 60079-15:2010
Code de certification
Ex nA [op is T4] IIC T3 Gc (–40°C ≤ Ta ≤ +70°C)
Code ATEX
II 3G
Conditions spéciales d'utilisation
L'équipement doit être installé dans une zone où le degré de pollution ne dépasse pas le
degré 2 conformément à l'IEC/EN 60664-1, et dans un boîtier qui fournit un niveau de
protection au moins égal à IP54 et conforme aux exigences applicables à EN 60079-0 et
EN 60079-15
Toutes les connexions externes à l'équipement et, le cas échéant, les modules SFP ne
doivent pas être insérés ou retirés sauf si la zone dans laquelle l'équipement est installé
est reconnue comme non dangereuse, ou si les circuits raccordés sont hors-tension.
Une fois les câbles réseau installés, ils doivent être correctement fixé grâce à des attaches
de câbles ou autre élément semblable afin de réduire le risque de débranchement
accidentel.
Paramètres d'entrée des équipements
Connecteur d'alimentation : +DC1, +DC2 & –COM
Double entrée d'alimentation 24 V à 48 VCC
Connecteur E/S : « Statut + » et « Statut – » et « Entrée digitale + » et « Entrée digitale – »
Tension maximale I/P = 60 VCC.
6643-22801
5
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified
conditions.
EN 50121-4, Railway signalling and telecommunications apparatus
IEC 62236-4, Railway signalling and telecommunications apparatus
SafetyUL/IEC/EN 60950-1, IT equipment
MarineDNV Standard for Certification no. 2.4
ExEN 60079-0 and EN 60079-15
FCC Part 15.105
Notice:
Corrosive
environment
Notice:
6
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
… Reorient or relocate the receiving antenna
… Increase the separation between the equipment and receiver
… Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
… Consult the dealer or an experienced radio/TV technician for help.
This product has been successfully tested in a corrosion test according to IEC 60068-2-60, method 3. This means that the product meets the requirements to be placed in an
environment classified as ISA-S71.04 class G3.
Note! If the product is placed in a corrosive environment, it is important that all un-used
connector sockets are protected with a suitable plug in order to avoid corrosion attacks
on the gold plated pins in connectors.
6643-22801
Declaration of Conformity
Org.nr/
th
Westermo Teleindustri AB
Declaration of conformity
The manufacturer
Herewith declares that the product(s)
Type of product Model 1
Industrial Ethernet 5-port Device Server Switch Lynx DSS L*05-S1-EX*
is in conformity with the following EC directive(s).
No Short name
2004/108/EC Electromagnetic Compatibility (EMC)
2011/65/EU Restriction of the use of certain hazardous substances in electrical and
References of standards applied for this EC declaration of conformity.
No Title Issue
EN 61000-6-1 Electromagnetic compatibility – Immunity for residential
EN 61000-6-2 Electromagnetic compatibility – Immunity for industrial
EN 61000-6-3 Electromagnetic compatibility – Emission for residential
EN 61000-6-4 Electromagnetic compatibility – Emission for industrial
EN 55024 Information technology equipment - Immunity 1998
EN 55022 Information technology equipment - Emission 2006
EN 50121-4 Railway applications - Electromagnetic compatibility
EN 60079-0 Explosive atmospheres
EN 60079-15 Electrical apparatus for explosive gas atmospheres –
The last two digits of the year in which the CE marking was affixed: 13
Westermo Teleindustri AB
SE-640 40 Stora Sundby, Sweden
electronic equipment (RoHS)
environments
environments
environments
environments
Emission and immunity of the signalling and telecommunications
apparatus
Equipment – General requirements
Construction, test and marking of type of protection “n”
2007
2005
2007
+A1:2011
2007
+A1:2011
+A1:2001
+A2:2003
+A1:2007
2006
2012
2010
Pierre Öberg
Technical Manager
December 2013
08
1
The first “*” in the model name can be any alphanumeric character, indicating software version. The second “*” in the
model name can be any alphanumeric characters indicating customer specific models, or blank.
15 cm
Steering/standby steering/emergency compass (18°/H deviation) = 10 cm
1.5 kVrms, 50 Hz, 1 min
8
6643-22801
Environmental
TemperaturesOperating–40 to +70°C (–40 to +158°F)*
HumidityOperating5 to 95 % relative humidity
AltitudeOperating2 000 m / 70 kPa
MTBFMIL-C217F2,
Service lifeOperating10 year
VibrationIEC 60068-2-6
ShockIEC 60068-2-27Operating30 g, 11 ms
BumpIEC 60068-2-27Operating10 g, 11 ms
Packaging
EnclosureEN 60950-1ZincFire enclosure
Dimension W x H x D
With connectors
Weight0.7 kg
Degree of protectionEN 60529EnclosureIP 40
CoolingConvection
* Refer to “Safety” section in User Guide.
** Might require Ethernet cables to be fastened close to the unit.
Parts count
(sine)
IEC 60068-2-64
(random)
Storage and transport –50 to +85°C (–58 to +185°F)
Storage and transport 5 to 95 % relative humidity
Ground Benign, 25°C
(77°F)
Operating3 – 13.2 Hz: 1mm
677 000 hours
13.2 – 100 Hz: 0.7 g
5 – 20 Hz: 2 m²/s³,
20 – 2000 Hz: – 3 dB/oct
100 g, 6 ms**
52.5 x 100 x 101 mm
52.5 x 119 x 101 mm
5.5 – 30 Hz: 1.5 g
30 – 50 Hz: 0.42 mm
50 – 500 Hz: 4.2 g**
6643-22801
9
Description
L105-S1 EX / L205-S1 EX is an Industrial switch and device server made for harsh
environments. WeOS is the operating system of L105-S1/L205-S1 enabling the unit
to operate in two functional levels. The switch can be used in either 10 or 100 Mbit
networks. Lynx DSS L105-S1 EX / L205-S1 EX has one serial port that supports RS-232.
Our unique FRNT (Fast Recovery of Network Topology) technology is the fastest
protocol on the market to re-configure a network in the event of any link or hardware
failure. That is why our products are used in safety critical applications such as tunnels,
traffic signal control and railway systems.
10
6643-22801
Interface specifications
Power
Operating voltageRated: 24 to 48 VDC
Rated current140 mA (290 mA) @ 24 VDC (with 500 mA USB load)
Rated frequencyDC
Inrush current, I2t22.7·10-3 A2s @ 48 VDC
Startup current*2 x Rated current
PolarityReverse polarity protected
Redundant power inputYes
Isolation toAll other
ConnectionDetachable screw terminal
Connector size0.2 – 2.5 mm2 (AWG 24 – 12)
Shielded cableNot required
* External supply current capability for proper start-up
Ethernet TX
Electrical specificationIEEE std 802.3. 2005 Edition
Data rate10 Mbit/s, 100 Mbit/s, manual or auto
DuplexFull or half, manual or auto
Circuit typeTNV-1
Transmission rangeUp to 150 m with CAT5e cable or better*
Isolation toAll other
ConnectionRJ-45, auto MDI/MDI-X
CablingShielded CAT5e or better is recommended
Conductive housingYe s
Number of ports4
* Refer to Safety section.
RS-232
Electrical specificationEIA RS-232
Data rate50 bit/s – 115.2 kbit/s
Data format7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
ProtocolTransparent, optimised by packing algorithm
Circuit typeSELV
Transmission range15 m / 49 ft
Isolation toAll other
ConnectionRJ-45 according to EIA-561
Shielded cableRecommended
Conductive housingYe s
Number of ports1
Operating: 19 to 60 VDC
70 mA (140 mA) @ 48 VDC (with 500 mA USB load)
6643-22801
11
I/O / Relay output
Pin 8
Pin 1
Maximum voltage/current60 VDC / 80 mA
Contact resistanceMax 30 Ω
Isolation toAll other
ConnectionDetachable screw terminal
Connector size0.2 – 2.5 mm2 (AWG 24 – 12)
I/O / Digital input
Maximum voltage/load current60 VDC / 2 mA
Voltage levelsLogic one: >12V
Electrical specificationUSB 2.0 host interface
Data rateUp to 12 Mbit/s (full-speed mode)
Circuit typeSELV
Maximum supply current500 mA
ConnectionUSB receptacle connector type A
Console
Electrical specificationLVTTL/LVCMOS-level
Data rate115.2 kbit/s
Data format8 data bits, no parity, 1 stop bit, no flow control
Circuit typeSELV
Connection2.5 mm jack, use only Westermo cable 1211-2027
RJ-45 connector (Front view)
MaleFemale
Pin 8Pin 1
12
Pin 1
Pin 8
6643-22801
Safety control drawing
Location of interface ports and LED’s
LED Indicators (for details see page 14)
RS-232
Position Signal Direction DescriptionInput/output values
No.1DSROutData Set Ready
No. 2DCDOutData Carrier Detect
No. 3DTRInData Terminal Ready
No. 4SG–Signal Ground, not chassis
I/O connection
(for details see page 10 and 13)
No. 5RDOutReceive Data
No. 6TDInTransmit Data
No. 7CTSOutClear To Send
No. 8RTSInRequest To Send
Power connection (for details see page 9 and 13)
USB
Position Direction* / descriptionOutput values
1Out / VBUS
2In/out / D–
3In/out / D+
4GND
ShieldPE
ground
U
= 5 VDC max
out
I
= 500 mA max
out
U = ±12 V max
I = ±60 mA max
Data rate:
50 bit/s – 115.2 kbit/s
6643-22801
Ethernet connection TX (4 ports)
Position Signale Direction DescriptionInput/output values
No.1TD+In/Out Transmitted/Received data
No. 2TD–In/Out Transmitted/Received data
No. 3RD+In/Out Transmitted/Received data
No. 4–Not Connected
No. 5–Not Connected
No. 6RD–In/Out Transmitted/Received data
No. 7–Not Connected
No. 8–Not Connected
ShieldConnected to PE
Galvanically isolated via signal transformers and capacitively isolated to
GND/PE through a 2kV 1000pF capacitor.
See user manual for proven transient protection.
Per port:
U = ± 1 V (4μV/s)
I = ± 20 mA
Data rate:
10/100 Mbit/s
13
Safety control drawing
I/O connection (for details see page 10 and 13)
Console port
(for details see page 10 and 13)
Bottom view
Cable 1211-2027
Connection to console port
The console port can be used to connect to the CLI
(Command Line Interface).
The following steps needs to be taken
1. Connect the serial diagnostic cable to the console port
(use only Westermo cable 1211-2027).
2. Connect cable to your computer (USB port, if drivers are needed they can be downloaded
from our Web page).
3. Use a terminal emulator and connect with correct speed and format (115200, 8N1)
to the assigned port.
For more information about the CLI, see the WeOS management guide.
Accessories
DescriptionArt no
Westermo console cable1211-2027
RJ45 to terminal block1200-2490
RJ45 to DB9 cable 1211-2210
14
6643-22801
Safety control drawing
Power connection
4-position
1
No. 1+DC1InputSupply voltage input DC1
2
No. 2+DC2InputSupply voltage input DC2
3
4
No. 3-COMInputCommon
No. 4-COMInputCommon
Lynx supports redundant power connection. The positive inputs are +DC1 and +DC2, the negative input for
both supplies are –COM. Connect the primary voltage (e.g. +24 VDC) to the +DC1 pin and return to one of the
–COM pins on the power input.
No. 2Status –OutputAlarm relay (status) contact Iin = 80 mA max
No. 3Digital in +InputDigital in +Uin = 60 VDC max
No. 4Digital in –InputDigital in –Iin = 2 mA max
The Status output is a potential free, opto-isolated normally closed solid-state relay.
This can be configured to monitor various alarm events within the Lynx unit, see WeOS Management Guide.
An external load in series with an external voltage source is required for proper functionality.
For voltage/current ratings, see Interface Specification section.
Console port
Position Direction* / description Input/output values
No.1 In / out / GND
No. 2 Out / Tx
No. 3 In / Rx
* Direction relative to this unit.
Product
marking
Product
marking
U = 3.3 VDC max
I = 24 mA max
DirectionDescriptionInput values
DirectionDescriptionInput / Output values
Uin = (19 – 60) VDC
Iin = 290 mA @ 24 VDC
PIn = 7 W @ 24 VDC
The Digital in is an opto-isolated
digital input which can be used to
monitor external events. For voltage/current ratings, see Interface
Specification section:
6643-22801
Lynx
External
Load
1
Status
2
3
4
V
+
V
–
Digital In
15
LED indicators
LEDStatusDescription
ONOFFUnit has no power.
GREENAll OK, no alarm condition.
REDAlarm condition, or until unit has started up.
BLINKLocation indicator ("Here I am!"). Activated when
DC1OFF
GREENPower OK on DC1.
REDPower failure on +DC1.
DC2OFFUnit has no power.
GREENPower OK on DC2.
REDPower failure on +DC2.
FRNTOFFFRNT disabled.
GREENFRNT OK.
REDFRNT Error.
BLINKUnit configured as FRNT Focal Point.
RSTPOFFRSTP disabled.
GREENRSTP enabled.
BLINKUnit elected as RSTP/STP root switch.
USR1OFF
RED
Rx/TD, TD OFFNo serial data received.
GREEN
FLASH
Tx/RD, RD OFFNo serial data transmitted.
GREEN
FLASH
1 to 4OFFNo Link.
GREENLink established.
GREEN
FLASH
YELLOW Port alarm and no link. Or if FRNT or RSTP mode,
(Alarm conditions are configurable, see ''WeOS
Management Guide'').
connected to IPConfig Tool, or upon request from
Web or CLI.
Unit has no power.
Configurable, see WeOS Management Guide.GREEN
Serial data received.
Serial data transmitted.
Data traffic indication.
port is blocked.
16
6643-22801
Mounting
This unit should be mounted on 35 mm DIN-rail, which is horizontally mounted inside an
apparatus cabinet or similar. It is recommended that the DIN-rail is connected to ground.
Snap on mounting, see figure.
Mounting Lynx with integrated DIN-clip:
Removal
Removing Lynx with integrated DIN-clip:
Press down the support at the back of the unit using a screwdriver. See figure.
Cooling
This unit uses convection cooling.
To avoid obstructing the airflow
around the unit, use the following
spacing rules. Minimum spacing 25 mm
(1.0 inch) above / below and 10 mm
(0.4 inches) left / right the unit.
Spacing is recommended for the use
of unit in full operating temperature
range and service life.
6643-22801
10mm10mm
17
Getting Started
This product runs Westermo Operating System (WeOS) which provides several
management tools that can be used for configuration of the unit.
• IPConfig tool
This is a custom Westermo tool used for discovery of attached Westermo units.
Note! Version of IP Config tool must be 10.4.0 or higher.
• Web
Configuration of the unit using the web browser.
• CLI
Configuration of the unit via the Command Line Interface.
Username: admin
Password: westermo
If the computer is located in the same subnet as the switch you can easily use a web
browser to configure the unit. Within the web you can configure most of the available
functions.
For advanced network settings and more diagnostic information, please use the CLI.
Detailed documentation is available in the chapter ”The Command Line Management
Tool” in the WeOS management guide.
Factory default IP address:192.168.2.200
Netmask:255.255.255.0
Gateway:Disabled
Note! If you are not sure about the subnet – consult your network administrator.
Configuration
Configure the unit via Web browser
The unit can easily be configured via a Web browser.
Open the link http://192.168.2.200 in your web browser, and you will be prompted with
a Login screen, where the default settings for Username and Password are:
Username: admin
Password: westermo
Once you have logged in, you can use the extensive integrated help function describing
all configuration options. Two common task when configuring a new switch is to assign
appropriate IP settings, and to change the password of the admin account.
The password can be up to 64 characters long, and should consist of printable ASCII
characters (ASCII 33-126); 'Space' is not a valid password character.
18
6643-22801
Referring documents
TypeDescriptionDocument number
Management GuideWestermo OS management guide
6101-3201
Factory default on L105-S1 EX / L205-S1 EX
It is possible to set the unit to factory default settings by using two straight standard
Ethernet RJ-45 cables.
1. Power off the switch and disconnect all Ethernet cables (copper and fibre).
2. Connect one Ethernet cable between Ethernet ports 1 and 4, and the other between
Ethernet ports 2 and 3.
The ports need to be connected directly by an Ethernet cable, i.e., not via a hub or
switch. Use a straight cable – not a cross-over cable – when connecting the ports.
3. Power on the unit.
4. Wait for the unit to start up. Control that the ON LED is flashing red.
The ON LED flashing indicates that the unit is now ready to be reset to factory
default. You now have the choice to go ahead with the factory reset, or to skip factory
reset and boot as normal.
• Go ahead with factory reset:
Acknowledge that you wish to conduct the factory reset by unplugging the
Ethernet cables. The ON LED will stop flashing.
This initiates the factory reset process*, and the unit will restart with factory default
settings. When the switch has booted up, the ON LED will show a green light, and is
now ready to use.
• Skip the factory reset:
To skip the factory reset process, just wait for approximately 30 seconds
(after the ON LED starts flashing RED) without unplugging the Ethernet cables.
The switch will conduct a normal boot with the existing settings.
* Note Do not power off the unit while the factory reset process is in progress.
6643-22801
19
Dimensions
Min 4mm
Max 7,5mm
100
±1
Measurements are stated in millimeters.
52
±1
96
±1
92
±1
±1
34
20
6643-22801
Westermo • SE-640 40 Stora Sundby, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
Sales Units
Westermo Data Communications
E-mail: info@westermo.com
www.westermo.com
China
sales.cn@westermo.com
www.cn.westermo.com
France
infos@westermo.fr
www.westermo.fr
Germany
info@westermo.de
www.westermo.de
For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code
REV.B 6643-22801 2015-01 Westermo Teleindustri AB, Sweden – A Beijer Electronics Group Company
North America
info@westermo.com
www.westermo.com
Singapore
sales@westermo.com.sg
www.westermo.com
Sweden
info.sverige@westermo.se
www.westermo.se
United Kingdom
sales@westermo.co.uk
www.westermo.co.uk
Other Offices
Loading...
+ hidden pages