SPECIFICATIONS
VOLTS
HP
115
1/3 7.015
CUTOUT DETAILS
AMPS SINGLE PHASE
LRA
MFS L1-N
29
45 1/4
(1149)
REFRIGERANT
R-404-A 24 OZ
AIR
FLOW
DESIGN PRESSURE
HIGH LOWQUANTITYTYPE
174500
25 7/8
(657)
POWER
SUPPLY
CORD
NEMA 5-15P
PRODUCT DIMENSIONS
46 1/2
(1181)
41 1/4
(1048)
INSTALLATION INSTRUCTIONS
REFRIGERATED COLD PAN
MODEL RCP-7300
AIR
19 7/8
(505)
FLOW
21 7/8
(556)
27 1/8
(689)
39 1/4
(997)
REMOVEABLE
1-PIECE
PAN RAIL
ELECTRONIC
TEMPERATURE
CONTROLLER
ADD
SUPPORTS
POWER
SWITCH
23
(584)
CROSS SECTION
FRONT VIEW
CONTROL SIDE
45
(1143)
CLEARANCES
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE.
FRONT
BOTTOM
SIDE
BACK
0
0
0
NA
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:
1. This unit may be installed in stainless steel, wood, Formica,
or Corian tables and countertops.
2. This unit is shipped completely assembled and requires
only a 15 AMP dedicated grounded outlet (NEMA 5-15R) and
drain connection. Power cord and Power Switch should be
accessible from the front of the unit.
3. When installing the unit it is essential to provide
side openings twice the surface area of the condenser for
adequate air circulation. Louvered grills with proper size
may be placed in each opening.
TO INSTALL:
1. Lay out "cutout" dimensions on countertop or table.
2. Cut out hole and add stiffeners to support weight
as shown. Countertop must be flat and level before
installing cold pan.
3. Apply a generous bead of silicone sealant to underĀside of mounting flange before setting unit into cutout.
Remove any excess sealant from top flange and countertop.
4. Connect 1 inch drain to drain pan or floor drain.
Consult local codes for approved drain connections.
AIR
FLOW
WELLS/BLOOMFIELD * VERDI, NV
1"NPT DRAIN
11 3/8
(289)
POWER
SUPPLY
3
(76)
CORD
5/16
(8)
1
(25)
1" NPT DRAIN
CROSS-SECTION OF COLD PAN
14 3/4
(375)
19
(483)
RIGHT SIDE VIEW
INCHES
(MM)
2 5/8
(67)
9 1/2
(241)
022403 FCN12397 305895-3 REV (-)
26 1/8
(664)