Wells RCP-7300 Installation Manual

SPECIFICATIONS
VOLTS
HP
115
1/3 7.015
CUTOUT DETAILS
AMPS SINGLE PHASE
LRA
MFS L1-N
29
45 1/4 (1149)
REFRIGERANT
R-404-A 24 OZ
AIR FLOW
DESIGN PRESSURE
HIGH LOWQUANTITYTYPE
174500
25 7/8
POWER SUPPLY
CORD
NEMA 5-15P
PRODUCT DIMENSIONS
46 1/2 (1181)
41 1/4 (1048)
INSTALLATION INSTRUCTIONS
REFRIGERATED COLD PAN
MODEL RCP-7300
AIR
19 7/8
FLOW
21 7/8
27 1/8
39 1/4
REMOVEABLE
1-PIECE
PAN RAIL
ELECTRONIC TEMPERATURE CONTROLLER
ADD
SUPPORTS
POWER SWITCH
23
CROSS SECTION
FRONT VIEW
CONTROL SIDE
45
(1143)
CLEARANCES
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE.
FRONT
BOTTOM
SIDE
BACK
0
0
0
NA
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED BELOW UPON INSTALLATION:
1. This unit may be installed in stainless steel, wood, Formica, or Corian tables and countertops.
2. This unit is shipped completely assembled and requires only a 15 AMP dedicated grounded outlet (NEMA 5-15R) and drain connection. Power cord and Power Switch should be accessible from the front of the unit.
3. When installing the unit it is essential to provide side openings twice the surface area of the condenser for adequate air circulation. Louvered grills with proper size may be placed in each opening.
TO INSTALL:
1. Lay out "cutout" dimensions on countertop or table.
2. Cut out hole and add stiffeners to support weight as shown. Countertop must be flat and level before installing cold pan.
3. Apply a generous bead of silicone sealant to underĀ­side of mounting flange before setting unit into cutout. Remove any excess sealant from top flange and countertop.
4. Connect 1 inch drain to drain pan or floor drain. Consult local codes for approved drain connections.
AIR FLOW
WELLS/BLOOMFIELD * VERDI, NV
1"NPT DRAIN
11 3/8
POWER SUPPLY
3
(76)
CORD
5/16
(8)
1
(25)
1" NPT DRAIN
CROSS-SECTION OF COLD PAN
14 3/4
19
RIGHT SIDE VIEW
INCHES
(MM)
2 5/8
(67)
9 1/2 (241)
022403 FCN12397 305895-3 REV (-)
26 1/8