Wells RCP-300 Installation Manual

SPECIFICATIONS
VOLTS
115
AMPS SINGLE PHASE
HP
LRA
1/4
38
L1-NMFS
REFRIGERANT
DESIGN PRESSURE
TYPE QUANTITY LOWHIGH
28 OZR-134-A
440 162
PRODUCT DIMENSIONSCUTOUT DETAILS
POWER SUPPLY
CORD
NEMA 5-15P
INSTALLATION INSTRUCTIONS
REFRIGERATED COLD PAN
MODEL RCP-300
AIR FLOW
43 1/4
(1099)
ADJUSTABLE PRESSURE SWITCH
ADD SUPPORTS
POWER SWITCH
23
(584)
43
(1092)
CLEARANCES
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE.
FRONT
BOTTOM
SIDE
BACK
0
0
NA
0
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED BELOW UPON INSTALLATION:
1. This unit may be installed in stainless steel, wood, Formica, or Corian tables and countertops.
2. This unit is shipped completely assembled and requires only a 15 AMP dedicated grounded outlet (NEMA 5-15R) and drain connection. Power cord and Power Switch should be accessible from the front of the unit.
3. When installing the unit it is essential to provide side openings twice the surface area of the condenser for adequate air circulation. Louvered grills with proper size may be placed in each opening.
TO INSTALL:
1. Lay out "cutout" dimensions on countertop or table.
2. Cut out hole and add stiffeners to support weight as shown. Countertop must be flat and level before installing cold pan.
3. Apply a generous bead of silicone sealant to underĀ­side of mounting flange before setting unit into cutout. Remove any excess sealant from top flange and countertop.
4. Connect 1 inch drain to drain pan or floor drain. Consult local codes for approved drain connections.
23 7/8
(606)
1" NPT
AIR FLOW
DRAIN
WELLS/BLOOMFIELD * VERDI, NV
24 1/2
(622)
POWER SUPPLY CORD
44 3/4
(1137)
9 3/4
(248)
40 3/4
(1035)
(25)
39 1/4
(997)
1
5/16
(8)
AIR FLOW
19 7/8
(505)
21 3/8
(542)
25 3/8
(643)
19
(483)
23 5/8
(600)
INCHES
(MM)
3/4
(19)
1" NPT DRAIN
CROSS-SECTION OF COLD PAN
022403 FCN12397 305894-3 REV (-)
2 3/4
(70)
8
(203)