SPECIFICATIONS
VOLTS
115
AMPS SINGLE PHASE
HP
LRA
38
INSTALLATION INSTRUCTIONS
REFRIGERATED COLD PAN
MODEL RCP-200
REFRIGERANT
L1-NMFS
15 5.51/4
TYPE QUANTITY LOWHIGH
28 OZR-134-A
DESIGN PRESSURE
440 162
POWER
SUPPLY
CORD
NEMA 5-15P
CUTOUT DETAILS
ADD
SUPPORTS
CLEARANCES
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE.
SIDE
BACK
0
0
ADJUSTABLE
PRESSURE
SWITCH
BOTTOM
NA
29 1/2
(749)
POWER
SWITCH
(584)
29 1/4
(743)
FRONT
0
PRODUCT DIMENSIONS
25 3/8
(645)
AIR
FLOW
23
1" NPT
DRAIN
AIR
FLOW
23 7/8
(606)
24 1/2
(622)
21 3/8
(543)
19 7/8
(505)
POWER
SUPPLY
CORD
AIR
FLOW
25 1/2
(648)
27
(686)
(787)
31
19
(483)
23 5/8
(600)
RIGHT SIDE VIEW
PLAN VIEW
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:
1. This unit may be installed in stainless steel, wood, Formica,
or Corian tables and countertops.
2. This unit is shipped completely assembled and requires
only a 15 AMP dedicated grounded outlet (NEMA 5-15R) and
drain connection. Power cord and Power Switch should be
accessible from the front of the unit.
3. When installing the unit it is essential to provide
side openings twice the surface area of the condenser for
adequate air circulation. Louvered grills with proper size
may be placed in each opening.
TO INSTALL:
1. Lay out "cutout" dimensions on countertop or table.
2. Cut out hole and add stiffeners to support weight
as shown. Countertop must be flat and level before
installing cold pan.
3. Apply a generous bead of silicone sealant to underĀside of mounting flange before setting unit into cutout.
Remove any excess sealant from top flange and countertop.
4. Connect 1 inch drain to drain pan or floor drain.
Consult local codes for approved drain connections.
9 3/4
(248)
WELLS/BLOOMFIELD * VERDI, NV
(25)
INCHES
(MM)
5/16
(8)
1
3/4
(19)
1" NPT DRAIN
CROSS-SECTION OF COLD PAN
022403 FCN12397 305894-2 REV (-)
2 3/4
(70)
8
(203)