Wells RCP-100 Parts List

Page 1
Model RCP-200
WELLS BLOOMFIELD, LLC
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439
telephone: 775-689-5703
fax: 775-689-5976
www.wellsbloomfield.com
OPERATION MANUAL
RCP-Series
DROP-IN
REFRIGERATED
COLD PANS
MODELS RCP-100 RCP-7100 RCP-200 RCP-7200 RCP-300 RCP-7300 RCP-400 RCP-7400 RCP-500 RCP-7500 RCP-600 RCP-7600
INSTALLATION
USE & CARE
405
Includes
IMPORTANT: DO NOT DISCARD THIS MANUAL
This manual is considered to be part of the appliance and is to be given to the OWNER or MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
this appliance. Additional manuals are available from your WELLS DEALER.
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS U S ING OR
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any
questions concerning installation, operation or maintenance of this equipment.
PRINTED IN UNITED STATES OF AMERICA
p/n 305101 Rev. D ECN-13538 M405 080915 cps
Page 2
LIMITED WARRANTY STATEMENT
All commercial cooking equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects in materials and workmanship for a period of one year from the date of original installation, or 18 months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser only, except that; with respect to cold/refrigerated products, warranty labor is limited to 90 days after installation. Extended warranty for labor and compressor are available at time of sale. Contact factory Sales Department for details.
THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES, INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, WHICH ARE HEREBY EXCLUDED.
WELLS SHALL NOT BE LIABLE FOR INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY CAUSE WHATSOEVER.
This warranty is void if it is determined that, upon inspection by an authorized service agency, the equipment has been modified, misused, misapplied, improperly installed, or damaged in transit or by fire, flood or act of God.
This warranty also does not apply if the serial nameplate has been removed, or if service is performed by unauthorized personnel. The prices charged by Wells Bloomfield for its products are based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge by a Wells Bloomfield factory authorized service agency or one of its sub-service agencies. This service will be provided on customer’s premises for non-portable models. Portable models (a device with a cord and plug) must be taken or shipped to the closest authorized service agency, transportation charges prepaid, for service. In addition to restrictions contained in this warranty, specific limitations are shown in the Service Policy and Procedure Guide. Wells Bloomfield authorized service agencies are located in principal cities. This warranty is valid in the United States and Canada and void elsewhere. Please consult your classified telephone directory, your foodservice equipment dealer or, for information and other details concerning warranty, contact:
Service Department, Wells Bloomfield, LLC
P.O. Box 280, Verdi, Nevada 89439
phone (775) 689-5707 or fax (775) 689-5976
SERVICE POLICY AND PROCEDURE GUIDE and ADDITIONAL WARRANTY EXCLUSIONS
1. Resetting of safety thermostats, circuit breakers, over load protectors, and/or fuse replacements are not covered by this warranty unless warranted conditions are the cause.
2. All problems due to operation at voltages or phase other than specified on equipment nameplates are not covered by this warranty. Conversion to correct voltage and/or phase must be the customer’s responsibility.
3. All problems due to electrical connections not made
in accordance with electrical code requirements and wiring diagrams supplied with the equipment are
not covered by this warranty.
4. Replacement of items subject to normal wear, to include such items as knobs, light bulbs; and, normal maintenance functions including adjustments of thermostats, adjustment of micro switches and replacement of fuses and indicating lights are not covered by warranty.
5. Damage to electrical cords and/or plug due to exposure
to excessive heat are not covered by this warranty.
6. Full use, care, and maintenance instructions supplied with each machine. Noted maintenance and
preventative maintenance items, such as servicing and
cleaning schedules, are customer responsibility. Those miscellaneous adjustments noted are customer responsibility. Proper attention to preventative maintenance and scheduled maintenance procedures will prolong the life of the appliance.
7. Travel mileage is limited to sixty (60) miles from an Authorized Service Agency or one of its sub-service agencies.
8. All labor shall be performed during regular working hours. Overtime premium will be charged to the buyer.
9. All genuine Wells replacement parts are warranted for ninety (90) days from date of purchase on non­warranty equipment. This parts warranty is limited only to replacement of the defective part(s). Any use of
non-genuine Wells parts completely voids any
warranty.
10. Installation, labor, and job check-outs are not
considered warranty and are thus not covered by this warranty.
11. Charges incurred by delays, waiting time or operating
restrictions that hinder the service technician’s ability to perform service are not covered by warranty. This includes institutional and correctional facilities.
405 p/n 305101 OpM RCP Refrigerated Cold Pans
SHIPPING DAMAGE CLAIM PROCEDURE
NOTE: For your protection, please note that equipment in
this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any
visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY: Regardless of the extent of the damage.
3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notify the transportation company or carrier immediately, and file “CONCEALED DAMAGE” claim with them. This should be done within fifteen (15) days from the date the delivery was made to you. Be sure to retain the container for inspection.
Wells Bloomfield cannot assume liability for damage or loss incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
xi
Page 3
TABLE OF CONTENTS
WARRANTY xi SPECIFICATIONS FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 3 AGENCY LISTING INFORMATION 3 INSTALLATION 4 OPERATION 6 CLEANING INSTRUCTIONS 8 TROUBLESHOOTING SUGGESTIONS 9 MAINTENANCE INSTRUCTIONS 10 PARTS & SERVICE 13 CUSTOMER SERVICE DATA 13
INTRODUCTION
Thank You for purchasing this Wells Bloomfield appliance.
Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance, and to use and care for the appliance in a manner which will ensure its optimum performance.
MODEL HP
RCP-100 RCP-200
RCP-300 RCP-7100 RCP-7200
RCP-400 RCP-7300
RCP-500
RCP-600 RCP-7400
405 p/n 305101 OpM RCP Refrigerated Cold Pans
RCP-7500 RCP-7600
ELECTRICAL & REFRIGERATION SPECIFICATIONS
AMPS 120VAC 1ø REFRIGERANT
TOTAL MCA MFS LRA TYPE AMT. HIGH LOW
1/4 5.5 8 15 38 R-134a 28 oz. 440 162 NEMA 5-15P
1/3 7.0 11 15 29 R-404a 24 oz. 500 174 NEMA 5-15P
1/2 7.5 12 15 33 R-404a 32 oz. 500 174 NEMA 5-15P
3/4 15.3 21 30 59 R-404a 54 oz. 500 174 NEMA 5-20P
PRESSURE
(psig)
POWER
SUPPLY
CORD
1
Page 4
FEATURES & OPERATING CONTROLS
NOTE:
This is a general arrangement drawing only. Actual component positions may vary between units.
2
405 p/n 305101 OpM RCP Refrigerated Cold Pans
Page 5
PRECAUTIONS AND GENERAL INFORMATION
This appliance is intended for use in commercial establishments only, and is intended consumption. No other use is manufacturer or its agents.
Operators of this appliance must be familiar with the appliance use, limitations and associated restrictions. Operating instructions must be read and understood by all persons using or installing this appliance.
Food must be kept in appropriate inserts. Never place food directly into the tank.
Cleanliness of this appliance is essential to good sanitation. Read and follow all included cleaning instructions and schedules to ensure the safety of the food product.
Disconnect this appliance from electrical power before performing any maintenance or servicing.
This appliance is not jet stream approved. Do not direct water jet or steam jet at this appliance, or at any control panel or wiring. Do not splash or pour water on, in or over any controls, control panel or wir­ing. Do not wash floor around this appliance with water or steam jet.
The technical content of this manual, including any wiring diagrams, schematics, parts breakdown illustrations and/or adjustment procedures, is intended for use by qualified technical personnel.
Any procedure which requires the use of tools must be performed by a qualified technician.
This manual is considered to be a permanent part of the appliance. This manual and all supplied instructions, diagrams, schematics, parts breakdown illustrations, notices and labels must remain with the appliance if it is sold or moved to another location.
This appliance is made in the USA. Unless otherwise noted, this appliance has American sizes on all hardware.
to hold pre-chilled prepared food for human
recommended or authorized by the
WARNING:
ELECTRIC SHOCK HAZARD
All servicing requiring access to non-insulated electrical components must be performed by a factory authorized technician. DO NOT open any access panel which requires the use of tools. Failure to follow this warning can result in severe electrical
shock.
CAUTION:
RISK OF
DO NOT connect or energize this appliance until all installation instructions are read and followed. Damage to the appliance will result if these instructions are not followed.
DAMAGE
405 p/n 305101 OpM RCP Refrigerated Cold Pans
3
Page 6
AGENCY LISTING INFORMATION
STD 4
STD 7
UL471
This appliance is performance tested to NSF Standard 4 for holding hot foods. This appliance conforms to NSF Standard 4 for sanitation only if
installed in accordance with the supplied Installation Instructions and
maintained according to the instructions in this manual.
This appliance performance tested to NSF Standard 7 for storage of potentially hazardous foods. This appliance meets NSF Standard 7 only when pan rails are installed in the lowest position.
RCP units are ETL listed for US and Canada
RCP units are evaluated to UL standard 471.
Components used in the manufacture of this unit are Underwriters Laboratory recognized.
4
405 p/n 305101 OpM RCP Refrigerated Cold Pans
Page 7
INSTALLATION
UNPACKING & INSPECTION
Carefully remove the appliance from the carton. Remove all protective plastic film, packing materials and accessories from the Appliance before connecting electrical power or otherwise performing any installation procedure.
Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the appliance before starting any
installation.
Read and understand all labels and diagrams attached to the appliance.
Carefully account for all components and accessories before discarding packing materials. Store all accessories in a convenient place for later use.
RCP units must remain upright at all times (shipping and installation) to prevent damage to the condensing unit. If the unit is accidentally tipped, allow unit to sit upright for at least 24 hours before connecting to electric power.
COMPONENTS
1 ea. PAN RAIL 1 - 5 ea. PAN ADAPTER BAR(S) ( qty differs with unit)
PREPARATION
Cutout dimensions for tank units and control panels are listed on the
Installation Instructions provided with the unit.
Provide at least 1" clearance around the condensing unit chassis.
Countertop must be flat and level before the unit is installed. After cutout is made, add stiffeners or bottom braces to counter as required to support unit weight.
IMPORTANT:
Refrigeration system is air cooled. Recommend louvered grills or equivalent openings front and rear, each with a minimum size of twice the surface area of the condenser, to provide adequate air circulation.
NOTE: The condenser fan is provided with a fan guard. DO NOT
remove the condenser fan guard.
Provide louvered grills and service access below control panel. Provide access to the POWER SWITCH and TEMPERATURE CONTROL UNIT located at the front of the condenser.
Verify that provided sealants are applied to the underside of the top flange prior to setting the unit into the cutout.
405 p/n 305101 OpM RCP Refrigerated Cold Pans
After installation, apply a thin bead of food-grade silicone sealant around the flange to seal it to the counter.
Avoid storing flammable or combustible materials in, on or near the appliance.
Clean the unit thoroughly after installation and before first use.
NOTE: DO NOT discard
the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation.
Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the
inside front cover of this manual.
WARNING:
RISK OF PERSONAL
Installation procedures must be performed by a qualified technician with full knowledge of all applicable electrical and plumbing codes. Failure can result in personal injury and property damage.
IMPORTANT:
Unit must remain in an upright position during installation to prevent damage to the refrigeration system.
IMPORTANT:
Refrigeration system is air cooled. Recommend louvered grills or equivalent openings front and rear, each with a minimum size of twice the surface area of the condenser, to provide adequate air circulation.
IMPORTANT:
Access is required for the operation of the drain valve and for maintenance of the refrigeration unit. Provide adequate access to the drain valve and refrigeration unit.
IMPORTANT:
Unit flange must be sealed to the counter top. Damage caused by leaks due to improper installation is NOT covered by warranty.
INJURY
5
Page 8
INSTALLATION (continued)
WARNING:
ELECTRIC
All servicing requiring access to non-insulated elec­trical components must be performed by a factory au­thorized technician. DO NOT open any access panel which requires the use of tools. Failure to follow this warning can result in severe electrical
shock.
SHOCK HAZARD
CAUTION:
RISK OF
DO NOT connect or energize this appliance until all installation instructions are read and followed. Damage to the appliance will result if these instructions are not followed.
DAMAGE
CAUTION:
ELECTRIC
Cord -connected units are equipped with a three-prong plug for your protection against electric shock. Never cut the large round prong from the plug, or twist a blade to fit an existing receptacle.
IMPORTANT:
Contact a licensed electrician to install the correct circuit and receptacle (cord­connected units) or to install and connect electric power (field-wired units).
IMPORTANT:
Damage due to being connected to the wrong voltage or phase is NOT covered by warranty.
SHOCK HAZARD
ELECTRICAL INSTALLATION
1. Refer to the nameplate. Verify the electrical service power. Voltage and phase must match the nameplate specifications. Wiring the unit to the wrong voltage can severely damage the unit, or cause a significant decrease in performance.
2. Available electrical amperage must meet or exceed the specifications listed on the specifications sheet provided with the unit.
a. Units are equipped with a three-prong (grounding) plug for your protection against electrical shocks. This must be plugged into a properly grounded matching receptacle. b. RCP-100 through RCP-600 and RCP-7100 through RCP-7400 are equipped with a NEMA 5-15P plug and require a matching NEMA 5-15R receptacle.
GROUND
PIN
NEMA 5-15P
PLUG
NEMA 5-15R
RECEPTACLE
c. RCP-7500 and RCP-7600 are equipped with a NEMA 5-20P plug and require a matching NEMA 5-20R receptacle.
GROUND
PIN
NEMA 5-20P
PLUG
NEMA 5-20R
RECEPTACLE
405 p/n 305101 OpM RCP Refrigerated Cold Pans
6
Page 9
INSTALLATION (continued)
PLUMBING INSTALLATION
Install 1" drain valve (provided by others) on unit drain. Plumb to an appropriate waste as required by local plumbing and sanitation ordinances. Consult local codes for approved drain configurations.
IMPORTANT:
DO NOT allow the sink drain spud to turn during installation. Hold the spud with an appropriate cross-guard-style spud wrench, or carefully grip the center threaded portion with a strap wrench or slip-joint pliers to immobilize the drain spud during drain fitting installation. DO NOT grip the drain spud nut or gasket.
IMPORTANT:
Plumbing connections must be made in compliance with all Federal, State and Local Codes and Ordinances.
IMPORTANT:
All drain plumbing installa­tions must be performed by a qualified plumber.
USE A SPUD WRENCH
0.25"
0.85" dia.
SINK DRAIN SPUD WITH CROSS GUARD
GASKET
NUT
OR ... GRIP
HERE
WHEN
ATTACHING
DRAIN
FITTING
405 p/n 305101 OpM RCP Refrigerated Cold Pans
7
Page 10
OPERATION
CAUTION:
ELECTRIC SHOCK HAZARD
DO NOT splash or pour water onto control panel or wiring.
RCP units are designed to hold REFRIGERATED PRE-CHILLED product at serving temperature.
RCP units should not be used to chill product, nor to hold
product for long term storage.
OPERATION NOTES
1. Never place food directly in cold pans. Always use insets or food pans.
2. Use only pre-chilled products. Stir product occasionally to maintain
chilled temperatures and prevent bottom freezing.
3. Use perforated bottom strainer plates when operating units with ice. Perforated bottom strainer plates are optional and must be ordered separately.
4. Models RCP-7100 thru RCP-7600 are NSF-7 listed for use with potentially hazardous foods.
5. Periodically clean condensing coils to remove accumulated dust and debris. Failure to clean coils will decrease performance and may void the warranty.
See CONDENSER CLEANING, page 8.
DAILY START-UP
1. Turn POWER SWITCH (located on condensing unit) ON. Allow
unit to run for approximately 30 minutes to reach operating temperature.
2. Add necessary adapter bars or adapter plates. Adapter bars provided with the unit are designed to hold 12" x 20" food pans up to 6" deep.
3. Install appropriate food pans or insets. Place pre-chilled product in food pans.
DAILY SHUT-DOWN
1. Turn POWER SWITCH OFF. Remove product, food pans and
adapters.
2. Allow unit to defrost before cleaning.
See CLEANING INSTRUCTIONS, page 7.
405 p/n 305101 OpM RCP Refrigerated Cold Pans
8
Page 11
CLEANING INSTRUCTIONS
PREPARATIONS: Turn POWER SWITCH OFF. Unplug unit or
disconnect from electric power. Allow unit to defrost before proceeding. Remove any insets, pans and/or adapter tops ( if used). Drain water from tank.
FREQUENCY: Daily
TOOLS: Warm Water and Mild Detergent Solution: 10 Parts Warm Water to 4 Parts Vinegar Plastic Scouring Pad Clean Cloth or Sponge Food-Grade Silicone Sealant
1. Remove pan adapter bars, pan rail and drain screen. Wipe interior of tank using a clean cloth or sponge and mild detergent.
2. Use a plastic scouring pad to remove any mineral deposits.
3. Rinse tank thoroughly with a vinegar and water solution to neutralize all detergent / cleanser residue.
4. Clean pan adapter bars and pan rail with a cloth or sponge dampened in clean water. Dry thoroughly, then reinstall.
5. Check drain screen, clean if necessary and reinstall.
6. Periodically inspect warmer flange-to-counter seal. Reseal with food-grade silicone sealant if necessary.
7. Inspect condenser. Clean if required.
8. Inspect cooling louvers in counter. Remove any lint or debris.
9. Reconnect to electric power. Turn POWER SWITCH ON only when
unit is to be used.
Procedure is complete
CAUTION:
ELECTRIC SHOCK HAZARD
DO NOT splash or pour water onto control panel or wiring.
IMPORTANT: DO NOT use steel wool for cleaning
405 p/n 305101 OpM RCP Refrigerated Cold Pans
9
Page 12
MAINTENANCE INSTRUCTIONS
CAUTION:
PERSONAL INJURY HAZARD
Disconnect appliance from electrical power before cleaning condenser coil.
CAUTION:
PERSONAL INJURY HAZARD
Condenser coil fins are sharp. Use care to avoid cuts while cleaning the condenser.
CONDENSER COIL CLEANING INSTRUCTIONS
The condenser coil must be kept clean to allow adequate air flow for proper heat dissipation. Recommend this procedure be performed monthly.
1. Turn POWER SWITCH OFF. Disconnect unit from electrical
power.
2. Remove louvers or access panel to allow coil to be reached.
3. Using a stiff bristle brush, brush lint and debris from the condenser fins. Brush vertically, top to bottom. Collect and discard all lint and debris gathered from this operation
IMPORTANT: The fins of the condenser coil are delicate and
easily damaged. Use care to brush only in a vertical motion to avoid damaging the coil fins.
4. Wipe the fan blades to remove accumulated lint.
5. Reconnect to electrical power. Test for proper operation.
10
405 p/n 305101 OpM RCP Refrigerated Cold Pans
Page 13
MAINTENANCE INSTRUCTIONS (continued)
CAUTION:
PERSONAL
Disconnect appliance from electrical power before cleaning.
Wells refrigerated cold pans are constructed of high quality stainless steel. As long as the stainless steel surface is intact, the equipment will not rust or corrode.
Recommendation: A water softening device or a cartridge-type filtration device may be used to minimize lime and calcium build-up.
INJURY HAZARD
405 p/n 305101 OpM RCP Refrigerated Cold Pans
11
Page 14
MAINTENANCE INSTRUCTIONS (continued)
IMPORTANT: DO NOT adjust the differential settings of the refrigeration system. Field adjustments of the differential settings must be made by qualified refrigeration personnel only. Unauthorized adjustment of the differential settings will void the warranty.
The temperature setting of the NSF-7 Refrigerated Cold Pan has been pre-set at the factory to meet most applications. An electronic temperature control maintains food temperature between 33ºF and 44ºF.
TEMPERATURE ADJUSTMENT
RCP-100 thru RCP-600
1. The temperature has been preset at the factory to meet most applications.
2. If temperature adjustments are required, the pressure switch, located on the condensing unit, is adjustable. Temperature adjustment must be performed by a qualified refrigeration personnel only.
3. Normal temperature setting would be 28ºF.
RCP-7100 thru RCP-7600
The LCD Display provides a readout of the sensor temperature during normal operation. Use the following to change the setpoint temperature:
1. To start programming, press SET key once. This will access the
Fahrenheit/Celsius mode. The readout will show the current
status, either F (degrees Fahrenheit) or C (degrees Celsius). Press either "up arrow" (Ï) or "down arrow" (Ð) to toggle between F and C designation.
2. Press SET again to access the setpoint. The LCD will display
the current setpoint, and the S1 annunciator will blink off and on to indicate that control is in the setpoint mode. Press either "up arrow" (Ï) to increase the setpoint, or "down arrow" (Ð) to decrease the setpoint to the desired temperature. Factory setpoint is 21ºF.
405 p/n 305101 OpM RCP Refrigerated Cold Pans
12
Page 15
MAINTENANCE INSTRUCTIONS (continued)
3. Press the SET key again to access the differential. The LCD will
display the current differential, and the DIF1 annunciator will blink off and on to indicate that control is in the differential mode.
IMPORTANT: DO NOT adjust the differential settings of the refrigeration system. Field adjustments of the differential settings must be made by qualified refrigeration personnel only. Unauthorized adjustment of the differential settings will void the warranty.
Press either "up arrow" (Ï) to increase the differential, or "down arrow" (Ð) to decrease the differential to the desired setting. Factory differential is 3ºF.
4. Press the SET key again to access the Heating / Cooling mode.
The LCD will display the current mode. Either "C1" for cooling or "H1" for heating. The control must be set to C1 for proper operation of the cold pan.
5. Press the SET key again to complete programming. Programming
ends automatically if no keys are pressed for 30 seconds. Any settings that have been input to the control will be accepted at that time.
6. Control settings are stored in non-volatile memory. Loss of power to the unit will not require reprogramming.
IMPORTANT: DO NOT adjust the differential settings of the refrigeration system. Field adjustments of the differential settings must be made by qualified refrigeration personnel only. Unauthorized adjustment of the differential settings will void the warranty.
405 p/n 305101 OpM RCP Refrigerated Cold Pans
13
Page 16
TROUBLESHOOTING SUGGESTIONS
14
405 p/n 305101 OpM RCP Refrigerated Cold Pans
Page 17
PARTS & SERVICE
DESCRIPTION PART NO. DRAIN SCREEN 21709
SOUP LADEL, 6 oz. 21764 ADAPTER BAR FOR 12" X 20" PANS 22016 PERFORATED BOTTOM PLATE STRAINER FOR RCP-100 (1 PC) 22107 PERFORATED BOTTOM PLATE STRAINER FOR RCP-200 (1 PC) 22108 PERFORATED BOTTOM PLATE STRAINER FOR RCP-300 (2 PC) 22109 PERFORATED BOTTOM PLATE STRAINER FOR RCP-400 (2 PC) 22110 PERFORATED BOTTOM PLATE STRAINER FOR RCP-500 (2 PC) 22111 PERFORATED BOTTOM PLATE STRAINER FOR RCP-600 (3 PC) 22112 PAN RAIL FOR RCP-7100 22696 PAN RAIL FOR RCP-7200 22697 PAN RAIL FOR RCP-7300 22698 PAN RAIL FOR RCP-7400 22699 PAN RAIL FOR RCP-7500 22700 PAN RAIL FOR RCP-7600 22701
IMPORTANT: Use only factory authorized service parts and replacement filters.
For factory authorized service, or to order factory authorized replacement parts, contact your Wells authorized service agency, or call:
Wells Bloomfield, LLC
2 Erik Circle P. O. Box 280 Verdi, NV 89439
Service Parts Dept. phone: (775) 689-5707 fax: (775) 689-5976
Service Parts Department can supply you with the name and telephone number of the WELLS AUTHORIZED SERVICE AGENCY nearest you.
CUSTOMER SERVICE DATA
RESTAURANT _____________________________ LOCATION _____________ INSTALLATION DATE ________________________ TECHNICIAN ___________ SERVICE COMPANY ________________________________________________ ADDRESS ___________________________ STATE ______ ZIP__________ TELEPHONE NUMBER (_____)_____-_________
EQUIPMENT MODEL NO. _______________ EQUIPMENT SERIAL NO. _______________
405 p/n 305101 OpM RCP Refrigerated Cold Pans
VOLTAGE: (check one)  120  _______
please have this information available if calling for service
15
Page 18
Genuine Parts
Protect - YOU - All - Ways
SERVICE TRAINING - QUALITY SERVICE
CUSTOMER SATISFACTION
Commercial Food Equipment Service Association
Wells Bloomfield proudly supports CFESA
Commercial Food Equipment Service Association
SERVICE TRAINING - QUALITY SERVICE
CUSTOMER SATISFACTION
WELLS BLOOMFIELD, LLC
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439
telephone: 775-689-5703
fax: 775-689-5976
www.wellsbloomfield.com
PRINTED IN UNITED STATES OF AMERICA