WELLS MANUFACTURING COMPANY
2 Erik Circle: P.O. Box 280Verdi, NV 89439
(702) 345-0444 FAX # (702) 345-0569
PC-1M PASTA RETHERMALI2ER
20Qv, 2200W, 10.6A
Installation and Operating Instructions
Plug power cord into appropriate receptacle (type
L6-20P ). Check nameplate for correct voltage.
2. Connect flexible water supply hose to fitting on
left side of unit (minimum 20 psi and .5 gpm water
supply required).
3. Close drain valve on left side of unit,
4. Place basket support rack in bottom of pan.
5. Close hinged cover.
6. Turn power switch to ON position. The red indicator
light will come on. The fill spout will automatically
fill unit with water to the correct operating level.
This takes approximately 5 minutes.
•
7. Allow the Pasta Rethermalizer to preheat for
30 minutes. The white thermostat indicator light
will cycle off when water is at correct operating
temperature.
8. Load one to three baskets with pasta and place in
preheated water. Press timer switch to energize cook
cycle. Yellow timer light will flash during cook
cycle. Alarm will sound at end of cook cycle. Press
timer switch to end cook cycle alarm. Remove pasta
baskets from water.
9. water level will be automatically maintained while
unit is turned on.
EPC09/25/9132002-IIPC-1M Rev. A
MANUFACTURERS OF COMMERCIAL COOKING EOUIPMENT
1.
Use breakfast cart to transport
Use necessary precautions, such as gloves, to handle hot rethermalizer, or
proportioner, and a warm solution of McD Sanitizer, wash and sanitize the
Make sure the water sensing probe on the
2.
3.
DAILY CLEANING PROCEDURES
PC-1M Pasta Rethermalizer
Place the power switch in the "OFF" position.
Unplug the rethermalizer. Disconnect water supply hose.
Open drain valve and drain water into appropriate container using attached
hose.
CAUTION: Equipment and water are hot.
4.
5.
6.
7.
the rethermalizer to sink area.
let it cool before handling.
Remove the portion baskets and basket support rack.
Using a hot solution of McD All Purpose Concentrate (APC) from the sink
side of the water pan and drain system are thoroughly cleaned.
Wash and sanitize portion baskets and basket support rack. Set aside to air
dry overnight.
CAUTION: Do not immerse rethermalizer in
water. Damage will occur if unit
is submerged.
Store rethermalizer in designated area.
CHECK CALIBRATION AND DE-LIME WATER PAN MONTHLY. MORE FREQUENT DE-
LIMING MAY BE NECESSARY IF WATER SUPPLY HAS HIGH MINERAL CONTENT.
9/91 :slc